An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ambulatory assessment of shoulder abduction strength curve using asingle wearable inertial sensor Pietro Picerno, PhD; Valerio Viero, MSc; Marco Donati, PhD; Tamara Triossi, MSc; Virginia Tancredi, PhD; Giovanni Melchiorri, PhD

  2. Aim • Assess reliability of using a single inertial measurement unit (IMU) for determining strength curves during isoinertial exercises. • Relevance • Strength curves have typically been measured with isometric and isokinetic dynamometers, which are expensive and cumbersome for clinicians.

  3. Method • 45 men and women without previous/current shoulder impairment and not involved in professional sports participated. • Seated subjects performed 1 consecutive shoulder abduction-adduction movement while holding 1 kg dumbbell. • Strength curve relative to shoulder abduction movement was assessed using wireless IMU fixed to upper arm.

  4. Results • High intraclass correlation coefficient values for range of motion and angular velocity. • Indicates high within-subject repeatability of task. • High waveform similarity of torque curves between trials. • With respect to isokinetic dynamometer, high IMU accuracy in estimating range of motion. • Error always <1.

  5. Conclusion • A single wearable IMU can effectively assess strength curves during isoinertial movements. • Clinicians could easily apply this method in ambulatory settings and, hence, use it as routine diagnostic tool for assessing functional joint recovery.