1 / 39

Part 2 Direct Reading Instrumentation

Part 2 Direct Reading Instrumentation. Direct Reading Instruments. Many different instruments Many different operating principles including: Electrochemical Photoionisation Flame ionisation Chemiluminescence Colorimetric Heat of combustion Gas chromatography

yosef
Télécharger la présentation

Part 2 Direct Reading Instrumentation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Part 2Direct Reading Instrumentation

  2. Direct Reading Instruments • Many different instruments • Many different operating principles including: • Electrochemical • Photoionisation • Flame ionisation • Chemiluminescence • Colorimetric • Heat of combustion • Gas chromatography • Many different gases & vapour • From relatively simple to complex

  3. Uses of Direct Reading Instruments • Where immediate data is needed • Personal exposure monitoring • Help develop comprehensive evaluation programs • Evaluate effectiveness of controls • Emergency response • Confined spaces

  4. Calculation of results Diffusion sampling: Conc (mg/m3) = W (µg) x A r x t where W = contaminant weight (µg) A calculation constant = 1000 / Sampling rate r = recovery coefficient t = sampling time in minutes Conc (ppm) = W (µg) x B r x t where W = contaminant weight (µg) B = calculation constant = 1000 x 24.45 / Sampling rate x mol wt r = recovery coefficient t = sampling time in minutes

  5. Uses of Direct Reading Instruments (cont) • For difficult to sample chemicals • Multi sensors • Multi alarms • Stationary installations • Fit testing of respirators • Video monitoring

  6. Limitations • Often costly to purchase • Need for frequent and regular calibration • Lack of specificity • Effect of interferences • Cross sensitivity • Need for intrinsically safe instruments in many places • Battery life • Sensors • Finite life, poisoning, lack of range

  7. Advantages • Direct reading • Continuous operation • Multi alarms • Multi sensors • TWA, STEL & Peaks • Data logging

  8. Other Limitations • Catalytic combustion detectors • React with other flammable gases • Poisoned by • Silicones • Phosphate esters • Fluorocarbons

  9. Single Gas Monitor • Interchangeable sensors including: • O2, CO, H2S, H2, SO2, NO2, HCN Cl2, ClO2, PH3 • STEL, TWA, peak • Alarm • Data logging Source: Industrial Scientific Inc – reproduced with permission

  10. Multigas Monitor • 1 – 6 gases • Interchangeable sensors: LEL, CH4, CO, H2S, O2, SO2, Cl2, NO, ClO2, NH3, H2, HCl, PH3 • STEL, TWA, peak • Alarm • Data logging

  11. Gas Badges • Two year maintenance free single gas monitor • Sensors include CO, H2S, O2 and SO2 • Turn them on & let them run out • Alarms • Some data logging ability Source: Industrial Scientific Inc – reproduced with permission

  12. Photo Ionisation Detectors (PID) • Dependent on lamp ionisation potential • Typically non specific VOCs or total hydrocarbons • Some specific eg benzene, NH3, Cl2 • Not for CH4 or ethane • Affected by humidity, dust, • other factors Source: Airmet Scientific-reproduced with permission

  13. Flame Ionisation Monitor • Similar to, PID but flame • Non specific, broad range • Less sensitive to humidity & other contaminants • Poor response to some gases • Needs hydrogen (hazard) Source: Airmet Scientific-reproduced with permission

  14. Portable Gas Chromatograph • Highly selective • Range depends on type of detector used • Complex instrument requiring extensive operator training • Non continuous monitoring Source: Airmet Scientific-reproduced with permission

  15. Infra-red Analyser • Organic vapours • Specific • Portable • Expensive

  16. Mercury Vapour Detectors • UV • Interferences: Ozone Some organic solvents • Gold Film • High cost • Gold film needs regular cleaning

  17. Maintenance & Calibration Source: Industrial Scientific Inc – reproduced with permission

  18. Guidelines for Using Gas Detection Equipment • Bump or challenge test • Daily before use, known concentration of test gas to ensure sensors working correctly • Calibration • Full instrument calibration, certified concentration of gas(es), regularly to ensure accuracy & documented • Maintenance • Regular services provides reassurance instruments repaired professionally & calibrated & documented

  19. Typical Basic Instrument Checks • Physical appearance • Ensure instrument is within calibration period • Turn instrument on and check battery level • Zero the instrument • Bump test (functionality test) instrument • Clear the peaks

  20. Standard Gas Atmospheres Primary Gas Standards • Are prepared from high purity 5.0 Gases (99.99999%) or 6.0 gases (99.999999%) by weighing them into a gas cylinder of known size Secondary Gas Standards • Are prepared volumetrically from these using gas mixing pumps or mass flow controllers Source: University of Wollongong

  21. Intrinsic Safety (cont) IECEx Standards • Equipment for use in explosive or Ex areas eg • Underground coal mines • Oil refineries • Petrol stations • Chemical processing plants • Gas pipelines • Grain handling • Sewerage treatment plants

  22. Intrinsic Safety (cont) Classification of zones Source: TestSafe – reproduced with permission

  23. Intrinsic Safety (cont) Gas or Explosive Groups • Group 1 Equipment used underground methane & coal dust • Group II Equipment used in other (above ground) hazardous areas IIA - least readily ignited gases eg propane & benzene IIB – more readily ignited gases eg ethylene & diethyl ether IIC – most readily ignited gases eg hydrogen and acetylene

  24. Intrinsic Safety (cont) Temperature classes Group I Surfaces exposed to dust less than 150°C Sealed against dust ingress less than 450°C Group II Source: TestSafe – reproduced with permission

  25. Intrinsic Safety (cont) Levels of Protection & Zones Source: TestSafe – reproduced with permission

  26. Intrinsic Safety Markings Example Smith Electronics Model TRE Ex ia IIC T4 Cert 098X Serial No. 8765 ia equipment suitable for zone 0 application IIC equipment is suitable for Gas Groups IIA,IIB, IIC T4 equipment is suitable for gases with auto ignition temp greater than 135°C

  27. Detector Tubes - Colorimetric Tubes Change in colour of a specific reactant when in contact with a particular gas or vapour Source: Dräger Safety – Reproduced with permission

  28. Advantages • Relatively inexpensive & cheap • Wide range of gases and vapours – approx 300 • Immediate results • No expensive laboratory costs • Can be used for spot checks • No need for calibration • No need for power or charging

  29. Limitations • Interferences from other contaminants • Need to select correct tube & correct range • Results should NOT be compared to TWA • Correct storage • Limited shelf life

  30. Colour Tubes / Badges Available For • Instantaneous short term measurement • Long term measurements – pump • Long term measurements – diffusion CHIP system • Based on colour reaction, but with digital readout of concentration

  31. End of Part 2

  32. Part 3Personal Air Sampler

  33. Air Sampling • There are various locations at which one may wish to take an integrated sample of a chemical in the plant air. • A general plant air sample is useful to give an overall measure of plant contamination. • One might also be concerned with escape of chemical at a known or suspected point source, such as an open vat, a spraying operation, or a valve. • Measurements made at a source of contaminant escape should not be used as values representing overall contamination of plant air. • Air collected at a point source will later be diluted by plant air or may be removed effectively by the ventilation system. • However., such a reading indicated hazard to a worker at the location and estimates the effectiveness of systems that clear the air.

  34. Air Sampling • A variety of stationary devices are available that either collect a sample for later analysis of give a direct reading of the contamination of the air at that location. • Such devices may depend on appearance of a specific absorption of infrared light, change in the transparency of a filter, change in the pressure drop across a filter, scattering of light by airborne particulate of variety of other techniques. • Devices are available to take samples automatically at timed intervals.

  35. PERSONAL AIR SAMPLERS • The most important air to sample is the air inhaled by the individual worker. Such air must be collected near the face. • Unless we wish to attach the worker by a tube to a large stationary device, which would restrict the free movement of the worker and thereby distort the results of the study, the entire apparatus must be small and lightweight enough to be carried about conveniently by the worker. • Such personal air samplers are available and are in common use. They consist of a small, battery-powered air pump that can be worn on the belt , to which a trapping device is attached. A tube pinned to the clothing near the face carries the air to the trapping device . 

  36. PERSONAL AIR SAMPLERS • The most important air to sample is the air inhaled by the individual worker. Such air must be collected near the face. Unless we wish to attach the worker by a tube to a large stationary device, which would restrict the free movement of the worker and thereby distort the results of the study, the entire apparatus must be small and lightweight enough to be carried about conveniently by the worker. This device, in spite of its small size, must meet adequate standards for analysis. • Such personal air samplers are available and are in common use. They consist of a small, battery-powered air pump that can be worn on the belt , to which a trapping device is attached. A tube pinned to the clothing near the face carries the air to the trapping device .

  37. End of Part 3

  38. Part 4 – Practice Problem

  39. Practice Problem 1

More Related