Aerial Apparatus Operator

Aerial Apparatus Operator. Positioning Aerial Apparatus. Positioning Aerial Apparatus. Position for maximum use minimum stress There are no hard and fast rules procedures vary with each incident. Tactical Considerations. Proper distance from building

yule
Télécharger la présentation

Aerial Apparatus Operator

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Aerial Apparatus Operator Positioning Aerial Apparatus

  2. Positioning Aerial Apparatus • Position for • maximum use • minimum stress • There are no hard and fast rules • procedures vary with each incident

  3. Tactical Considerations • Proper distance from building • maximum stability and best climbing angle • Ladder stress • stresses work against strength of aerial

  4. Tactical Considerations • Tactical use of aerial device • rescue • access to upper levels • ventilation • fire suppression

  5. Tactical Uses:Rescue • Best approach is from up wind • Place at corner of building if possible • allows for rescue on two sides • Hose lines should be used for protection from fire

  6. Tactical Uses:Access to Upper Levels • Operations requiring access • Interior truck work • Using hand lines off aerial • Means of escape • Method of deploy equipment

  7. Tactical Uses:Access to Upper Levels • Position upwind when possible • Position should afford maximum safety

  8. Tactical Uses: Ventilation • Important function of truck company • Proper position makes job safer and quicker • Position as close as possible • Aerial device should extend above roof

  9. Tactical Uses: Ventilation • For horizontal ventilation • use same rules as for ground ladders

  10. Tactical Uses:Fire Suppression • Offensive attack • Give as much reach to fire as possible • Be aware of position of interior crews

  11. Tactical Uses:Fire Suppression • Defensive attack • Stream used directly on fire • Position further from building

  12. Spotting Considerations • Surface conditions • Weather • Electrical hazards • Overhead obstructions • Angle of operation • Location of operation • Fire building condition

  13. Staging • Level 1 • Applied to initial response • Used when two companies are responding

  14. Staging • Level 2 • Used in greater alarm situations • Designated when additional units are requested

  15. Limited Access Highways:Problems • Access • Water Supply • Safety of Other Drivers • Fire Fighter Safety