1 / 35

Ion Beam Analysis Today and Tomorrow

Ion Beam Analysis Today and Tomorrow. Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest. 20+5 min. IBA. RBS. NRA. PIXE. ion. ERD. Ion Beam Synthesis. Doping. Damage. Ion Implantation. The incident beam. Accelerators - Used ones (5 MeV VdG, …)

zared
Télécharger la présentation

Ion Beam Analysis Today and Tomorrow

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ion Beam Analysis Today and Tomorrow Ferenc Pászti Research Institute for Particle and Nuclear Physics, Budapest 20+5 min

  2. IBA RBS NRA PIXE ion ERD Ion Beam Synthesis Doping Damage Ion Implantation

  3. The incident beam • Accelerators • - Used ones (5 MeV VdG, …) • - Smaller and cheaper (200 keV FIB, …) • - Special designs (3 MeV Tandem) • Radioactive sources (planetary research) • Beam size • - Normal (1x1 mm2) • - Microbeam (1x1 mm2)

  4. 5 MeV Van de Graaff Accelerator (EG-2R) at RIPNP, Budapest

  5. 1MeV tandem at Cambridge (GC¯AMS) B. J. Hughey, Nucl. Instr. Meth. B 172 (2000) 40.

  6. 2MeV Tandem at Louvre Paris (AGLAE) http://www.culture.gouv.fr/culture/conservation/fr/methodes/aglae.htm

  7. RBS

  8. Main parameters • Elements è heavier than the ion • Isotopes è for light elements • Depth of analysis è few 100nm (few mm) • Depth resolution è few 10nm (few Å) • Sensitivity è few at% (light) - • few 100 ppm (heavy)

  9. Channel Number RBS spectra (3.045 MeV 4He) of Co implanted Si and a porous Si. A.R.Ramos, Nucl. Instr. Meth. B 178 (2001) 283.

  10. ERD

  11. Suppressing the scattered ions • Absorber foil • Kinematics • Coincidence • Element identification (DE-E, TOF-E, ExB…) • …

  12. Main parameters • Elements è Lighter than the ion Isotopes è for light elements • Depth of analysis è few 100nm • Depth resolution è few 10nm (few nm) • Sensitivity è few 0.1% (few ppm)

  13. ERD spectrum from a thin, 200 Å, deuterated polystyrene film J. Russel, Mat. Sci. Eng. R 38 (2002) 107.

  14. 2D ERD spectra from a GaN film with impurities (200 MeV Au ions, DE-E gas detector) H. Timmers, Nucl. Instr. Meth. B 190 (2002) 393.

  15. NRA

  16. Suppressing the scattered ions • Ions (p, d, a, …) • Positive Q value, filter foil • n or g • Special detectors

  17. Main parameters • Elements è specific • Isotopes è specific • Depth of analysis è few 10nm - few mm • Depth resolution è few nm - few mm - ∞ • Sensitivity è few ppm

  18. 12C(d,p)13C NRA spectra of olivine with 1000 ppm C content (1.45 MeV d, 9 mm Al filter foil) M.E.Varela, Geochimica et Cosmochimica Acta 64 (2000) 3433

  19. PIXE

  20. Main parameters • Elements è heavier • Isotopes è no • Depth of analysis è few mm • Depth resolution è no • Sensitivity è few % - few 10 ppm

  21. PIXE spectra taken from tissues of thyroid Normal Adenoma Cancer S.B. Reddy, Nucl. Instr. Meth. B in print

  22. Channeling

  23. Basic principle of channeling

  24. Channeling RBS spectra of He and N-implanted and annealed Si. Virgin and random spectra are also included. (1016 ion/cm2 units) A. Manuaba, Nucl. Instr. Meth. B (2001) 63

  25. Lattice localization of Er in sapphire by RBS/channeling E. Alves, Nucl. Instr. Meth. B 106 (1995) 429

  26. Microprobe

  27. Schematic diagram of the 200 kV FIB microprobe at Osaka University. 80 nm lateral resolution, Si, Be Au ions. J. Tajima, Nucl. Instr. Meth. B 181 (2001) 44.

  28. 300 keV Be2+ Secondary electron and RBS mapping images by the FIB microprobe. Y.K. Park, Nucl. Instr. Meth. B 158 (1999) 487.

  29. Future

  30. New accelerators for IBA • Cheaper and smaller accelerators for routine applications • Larger used machines (HI-ERDA) • Better microprobes • Transportable IBA?

  31. Unique features • Channeling for damage profiling and lattice localization • H depth profiling • Atomic depth resolution • Extreme sensitivity

  32. New methods appear • Pore structure determination by resonance method • Combination of TOF-RBS and TOF-SIMS by a nanoprobe • …

  33. R-BS spectra on columnar porous Si (3045+100 keV 4He+). The peak is due to 16O(a,a) resonance. At tilt 0° the beam is parallel to the pores. F. Pászti, Vacuum. 50 (1998) 451.

  34. Half-width of the resonance peak for samples implanted at various tilts and fluencies. Solid lines are fitted Lorentzian curves. F. Pászti, Nucl. Instr. Meth. B 161-163 (2000) 963.

  35. As implanted SiO2 As implanted Si 25 nm Au on Si 200 keV Si2+ TOF spectra by the 200keV FIB. H, O, C peaks are due to secondary ions accelerated by the 1.8 kV detector bias of the MCP (TOF-SIMS). K. Iwasaki, Nucl. Instr. Meth. B 190 (2002) 296.

More Related