1 / 9

NSTX

NSTX. Supported by. NSTX Centerstack Upgrade Project Meeting P. Titus Feb 3, 2010. Dome Rib Tab Weld Stress Removing TF OOP Support to the Vessel. Design Point PF Forces. /title,PF4 and PF5 Upper Worst Power Supply Loads Plus TF OOP Loads bf,all,temp,20

alisa
Télécharger la présentation

NSTX

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NSTX Supported by NSTX Centerstack Upgrade Project Meeting P. Titus Feb 3, 2010 Dome Rib Tab Weld Stress Removing TF OOP Support to the Vessel

  2. Design Point PF Forces

  3. /title,PF4 and PF5 Upper Worst Power Supply Loads Plus TF OOP Loads bf,all,temp,20 f,985,fz,-168089/12/.2248 !PF1c f,402,fz,-194414/11/.2248 !PF2 f,4588,fz,-100000 !Umb Foot f,4588,fy,60000 f,1237,fz,-303940/11/.2248 !PF3 solve

  4. Weld Allowable From the NSTX Criteria: • For welds in steel, the design Tresca stress shall be the lesser of: • 2/3 of the minimum specified yield if the weld at temperature, or • 1/3 of the minimum specified tensile strength of the weld at temperature. From the AISC Criteria: For shear on an effective throat of a fillet, For 304 Stainless, the weld metal is annealed, or the base metal in the heat effected zone is annealed. and Estimate 241*21/36 = 140 MPa = 20 ksi (without weld efficiency) This is consistent with NSTX Criteria of 2/3 yield or 2/3 of 30ksi for annealed 304 With a weld efficiency of .7 the allowable is 14ksi, or 96 MPa For fillets divide weld area by sqrt(2)

  5. Rib Tab Weld Evaluation forWorst Case Power Supply Loads Actual Weld Detail Assume bevel backed by a fillet is like a full penetration. Tab weld Stresses all appear less than 96 MPa

  6. Sri Checked Vessel Stresses with Correct NB Port, and Han’s Worst OOP Loads – Vessel Stress is OK.

  7. TF Stress, - No Outer Leg OOP Support Note Scenarios beyond around #50 died due to filled disk

  8. OOP Displacement, - No Outer Leg OOP Support

More Related