1 / 6

Introduction to Sensors and Calibration Factors

Introduction to Sensors and Calibration Factors. Choosing a suitable recording range on a data logger Logger will have several range options: e.g. -10 to +10 mV, -100 to +100 mV, -1000 to +1000 mV

Jims
Télécharger la présentation

Introduction to Sensors and Calibration Factors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Introduction to Sensors and Calibration Factors

  2. Choosing a suitable recording range on a data logger Logger will have several range options: e.g. -10 to +10 mV, -100 to +100 mV, -1000 to +1000 mV To choose the optimum range…Step 1: Estimate the expected max and min values of the variable being measured.Step 2: Obtain the calibration factor of the sensor (e.g. 10 mV / degree C for a temperature sensor)Step 3: Estimate the max and min signals expected by multiplying info from Step 1 by info from Step 2.Step 4: Choose range to get best precision without over-ranging. Which of the above range options would you choose for a temperature sensor with cal factor of 1mv / degree C?

  3. Let’s work out best logger ranges for sensors you will be using. Temperature1. Max and min values?2. Calibration factor?3. Max and min signals?4. Best range? Relative Humidity1. Max and min values?2. Calibration factor?3. Max and min signals?4. Best range?

  4. Wind Speed1. Max and min values?2. Calibration factor?3. Max and min signals?4. Best range? Wind Direction1. Max and min values?2. Calibration factor?3. Max and min signals?4. Best range?

  5. Solar Radiation1. Max and min values? 0 to 1200 W/m22. Calibration factor?3. Max and min signals?4. Best range? Net Radiation1. Max and min values? -100 to +1000 W/m22. Calibration factor?3. Max and min signals?4. Best range?

  6. Soil Temperature (thermocouple or thermistor)1. Max and min values?2. Calibration factor3. Max and min signals?4. Best range? Precipitation1. Max and min values? - not required. Sends pulse data.2. Calibration factor? 3. Max and min signals? - 0 or accumulated counts. 4. Best range? Use a pulse channel on logger.

More Related