LabtronUS
Uploaded by
4 SLIDES
5 VUES
0LIKES

Atomic-Absorption-Spectrophotometer-LAAS-A20

DESCRIPTION

Labtron atomic absorption spectrophotometer operates between 180-900 nm with a 6-lamp holder for versatile analysis. It features a hollow cathode lamp for efficiency and a deuterium lamp for background correction. The graphic analysis system tracks values, temperature, and procedures. With automatic ignition and data processing, it ensures accuracy and ease in documentation.<br>

1 / 4

Télécharger la présentation

Atomic-Absorption-Spectrophotometer-LAAS-A20

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Atomic Absorption Spectrophotometer LAAS- A20 www.labtron.com info@Labtron.com |

  2. Overview Atomic absorption spectrophotometer designed with the latest technology, can automatically accomplish safety ignition and reproducibility of the flame method. The graphic analysis system gives information on analysis of the whole process e.g. measured value, temperature, procedures, time, etc. It consist of hollow cathode lamp to improve the analysis efficiency and accuracy of the flame & deuterium lamp for background correction. Features : 1800 /mm reticle (dispersion rate) large area grating Monochromator Titanium burner for the flame analysis Polymer automization chamber Automatic analysis ensures sensitivity and reproducibility of the flame method Light source 6 lamp holder Graphic furnace system gives information on analysis of the whole process Convenient data processing & sharing & printing Powerful software with automatic instrument and additional control

  3. Specifications : Wavelength range 180 - 900 nm 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting) Spectral Bandwidth Wavelength accuracy ≤ 0.15 nm Wavelength repeatability ± 0.1 nm ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic) Baseline drift Absorbance Range 0 - 4 A Detector Imported photomultiplier tube ≤ 6 lamps automatic turret, automatic alignment Lamp holder Lamp power supply mode pulsed power supply large 1800 /mm grating ruling, full closed optical system Optical System Polymer explosion-proof spray chamber Atomization Chamber Characteristic concentration (Cu) 0.015 μg / mL / 1 % Detection Limit (Cu) 0.002 μg/mL Full titanium combustion head, 50 mm or 100 mm general combustion head Burner Atomizer efficient glass atomizer,can also be customized Nebulizer Precision RSD ≤ 0.5 % Microcomputer control, automatic ignition Ignition Type

  4. Gas Control Automatic gas control system Flame method, Hydride generation- Atomic absorption method Measurement Standard curve method(1 - 3 times curve), automatic fitting Concentration calculation 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. The number of repeated measurements Print the final stages of test data or analysis. The results can be exported into Excel worksheet. Print results 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA Power supply Applications : Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom Email: | Website: info@Labtron.com www.labtron.com

More Related