HPLC-system-LHLC-A10

DESCRIPTION

HPLC system includes a high-pressure pump with a diaphragmatic damper for precise pressure control. A UV detector identifies colorless, odorless samples, while pulse suppression ensures low baseline noise. Automatic column washing and user-friendly software with auto-boot detection enhance usability.

1 / 4

Télécharger la présentation

HPLC-system-LHLC-A10

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HPLC system LHLC-A10 www.labtron.us info@labtron.us |

  2. Overview This HPLC system is equipped with high-pressure constant-current pump and UV detector. Pressure pulsation is controlled by diaphragmatic damper in seconds. The UV detectors helps in identification of samples and elutes that are colourless, odourless in nature. There is auto boot detection function available in this HPLC system. Specifications : High pressure pump Single pump Flow rate range 0.001 - 9.999 mL / min (0.001 mL / min increment) Pressure range ≤ 0.5 MPa (0 - 42 MPa) Flow rate precision RSD < 0.06 % Pulsation ≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa) Qualitative analysis RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent) Quantitative repeatability RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent) Flow rate setting error Ss ≤ 2 % (1 mL / min water, 5 - 10 MPa, room temperature) Mixing accuracy ± 1 % Mixing precision ± 0.2 % Size (W × H × D) 450 × 300 × 160 mm

  3. UV Detector Wavelength range 190 - 680 nm Flow cell 8 µL Spectrum band width 8 nm -5 Baseline noise ≤ ± 0.25 × 10 (empty cell) AU Wavelength accuracy ± 1 nm -4 Baseline drift ≤ ± 0.4 × 10 (empty cell) AU Wavelength precision < 0.1 nm -9 Limit of detection 3 × 10 (naphthalene methyl alcohol solvent) g / mL Size (W × H × D) 450 × 300 × 160 mm Features : - Limit baseline noise can be ensured using electronic pulse suppression technique - High pressure single pump - Easy to change gasket ring & automatic washing function for the column - User-friendly software for smooth operations

  4. Applications : The HPLC has applications in separation of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis. Labtron Equipment Ltd.Quatro House,Lyon Way,Camberley,SurreyGU16 7ER, United Kingdom Email: | Phone: +44 2080 043 608 info@labtron.us Website: www.labtron.us