1 / 5

Magnetic measurements of MICE target stator

Magnetic measurements of MICE target stator. Ben Shepherd MICE target meeting 11 October 2010. Further measurements of B2 centre. Repeated measurements of longitudinal field B2(x,y) to find minimum on magnetic axis Approximate offsets: x = -0.4mm; y = 0.2mm. Probe offset.

afra
Télécharger la présentation

Magnetic measurements of MICE target stator

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Magnetic measurements of MICE target stator Ben Shepherd MICE target meeting 11 October 2010

  2. Further measurements of B2 centre • Repeated measurements of longitudinal field B2(x,y) to find minimum on magnetic axis • Approximate offsets: x = -0.4mm; y = 0.2mm

  3. Probe offset • An additional complication: the probe has a cross-hair on the end but this may not mark the position of all three Hall plates • Flipped the probe through 180° and repeated some measurements • Average of (before, after) flip: tends to bring offset closer to axis

  4. Overall summary • All points in this graph are averages of before and after flipping the probe over • B2 (longitudinal) field results are quite consistent • B0, B1 (transverse) field results all over the place!

  5. What next? • The B2 centres (after averaging) are all clustered around (x,y) = (-0.1,0.1) mm • The B0, B1 centres are inconsistent with this • How about connecting up individual coils?

More Related