1 / 10

Metop-A and Metop-B at FBKS

Metop-A and Metop-B at FBKS. by: NOAA/Cheryl Evry Tel.: +1-301-817-4224 Mail: cheryl.evry@noaa.gov. 20 Metop weekly TM/TC Proficiency Passes 1 Dec 2012 to 30 April 2013. 20 Metop TM/TC Test Passes Issues. Equipment Issues Router needed reset - 1 Cortex - 3

alaric
Télécharger la présentation

Metop-A and Metop-B at FBKS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Metop-A and Metop-B at FBKS by: NOAA/Cheryl Evry Tel.: +1-301-817-4224 Mail: cheryl.evry@noaa.gov

  2. 20 Metop weekly TM/TC Proficiency Passes 1 Dec 2012 to 30 April 2013

  3. 20 Metop TM/TC Test PassesIssues

  4. Equipment Issues • Router needed reset - 1 • Cortex - 3 • TM Drops (cause not stated) - 3 • Other Issues • Pass information provided to the EPS controller team was incorrect. • Not on NOAA Schedule, configured for pass after brief. • Solutions • Schedulers now integrate passes into LEO-T • IJPS Equipment Refresh

  5. 18 Metop GDS Test Passes

  6. Issues • File did not build correctly on FXS Server • Not added to schedule (due to Priority Issue - ok) • Possible Old TLEs • Resolutions • Procedures issued for every maneuver to reload TLEs as needed. • Procedure 1303191610_metop GDS proficiency passes requesting checksums be provided for every test file • IJPS Equipment Refresh

  7. Notes • EX-4 is a model of PTP, which is a programmable telemetry processor receives the high-rate (x-band) data; breaks out packets into VCs. This would be the source of the improper time stamping and naming. • FXS is the Fairbanks Transfer Server - puts all of the VCs into one file, prepares them to send out (GDS server) • Dataflow is from the antenna to the EX-4 to the FXS. The machines set up for a pass by the FXS setting up the EX-4.

  8. Data Quality • At the beginning of this testing, only Antenna C had proper timestamping. • For Antenna A, the files are being processed/stored on the Antenna B EX-4 and FXS. Thus Antenna A and B are using the same equipment. (This will change with refresh.) •  The EX-4 on Antenna A/B was incrementing much faster than the one on Antenna C.

  9. Data Quality • The “desktops” on the EX-4’s matched between A/B and C. The registry settings on the EX-4 were also checked and matched Antenna C. • On 19 March, Fairbanks requested to put a 1PPS (1 pulse per second) unit on the Antenna A/B unit. • After that point, all files received had proper timestamping.

  10. File Naming • The old equipment can only handle M01 files but with the new equipment the file names for M01 and M02 can be handled without issue.