1 / 11

DEVELOPMENT OF RADIATION HARD DETECTORS

DEVELOPMENT OF RADIATION HARD DETECTORS. Helsinki Institute of Physics (HIP) In close cooperation with: Microelectronics Centre, Helsinki University of Technology, Finland Accelerator Laboratory, University of Jyväskylä, Finland Okmetic Ltd., Finland Ioffe PTI, Russia

arin
Télécharger la présentation

DEVELOPMENT OF RADIATION HARD DETECTORS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DEVELOPMENT OF RADIATION HARD DETECTORS Helsinki Institute of Physics (HIP) In close cooperation with: Microelectronics Centre, Helsinki University of Technology, Finland Accelerator Laboratory, University of Jyväskylä, Finland Okmetic Ltd., Finland Ioffe PTI, Russia Brookhaven National Laboratory, USA University of Hamburg, Germany CERN RD39 & RD50 Eija Tuominen 26.09.2003

  2. OUTLINE • Why Radiation Hard Detectors • Why Czochralski Silicon Detectors • Detector Processing • Detector Characterization • Detectors in Particle Beam • Radiation Hardness of the Detectors Eija Tuominen 26.09.2003

  3. WHY RADIATION HARD RADIATION DETECTORS Silicon particle detectors are cost effective and have excellent positionresolution. Exposure of the silicon material to particle radiation causes irreversible defects that deteriorate the performance of the silicon detectors Our approach: oxygen in silicon Eija Tuominen 26.09.2003

  4. WHY CZOCHRALSKI SILICON DETECTORS I • Radiation hardness • * Oxygen increases the radiation hardness of silicon detectors • * Cz-Si intrinsically contains oxygen, 1017-1018 cm-3 • Cost-effectiveness • * Cz-Si wafers are cheaper than traditional Fz-Si wafers • * Large area wafers available -> possibility for large detectors -> cost-effectiveness for front-end electronics, interconnection and module assembly Eija Tuominen 26.09.2003

  5. WHY CZOCHRALSKI SILICON DETECTORS II 3. High oxygen concentration allows some additional benefits * Depletion voltage of detectors can be tailored by adjusting a) oxygen concentration in the bulk b) thermal history of wafers (Thermal Donor killing) WHY NOT BEFORE? * No demand for high resistivity Cz-Si -> No availability * Price for custom specified ingot 15,000 € - 20,000 € * Now RF-IC industry shows interest on high resistivity Cz-Si (=lower substrate losses of RF-signal) * Cz-Si of resistivity 5kcm reported: T.Abe and W.Qu, High resistivity CZ silicon for RF applications substituting GaAs”, Electrochemical Society Proc. Vol. 2000-17 (2000) 491-500. Eija Tuominen 26.09.2003

  6. DETECTOR PROCESSING Processed at the Clean Room of Helsinki University of Technology Microelectronics Center (MEC) Silicon Material: * 4” single side polished * nominal resistivity 900 cm * thickness 380 um * grown by magnetic Czochralski method (MCZ) -> oxygen concentration is ”low” <10 ppma and well controlled Simple Fabrication Process: 4 Lithographies 2 Ion implantations 2 Thermal dry oxidations 3 Sputter metal depositions Eija Tuominen 26.09.2003

  7. DETECTOR CHARACTERIZATION I:ELECTRICAL PROPERTIES Large Area Detectors: A = 32.5 cm2 IL(900 V) = 3 uA Vfd = 420 V (380 um) No Breakdown <1000V = Good Detectors for Silicon Trackers Measured at HIP/Kumpula, Oulu University, and CERN Eija Tuominen 26.09.2003

  8. DETECTOR CHARACTERIZATION II:CHARGE CARRIER LIFETIMES Cz-Si Fz-Si Measured by Photoconductive Decay (PCD) method at Helsinki University of Technology, Electron Physics Laboratory Eija Tuominen 26.09.2003

  9. DETECTION PERFORMANCE Measured by HIP Silicon Beam Telescope at CERN * eight silicon detectors * front-end electronics with VA1 chips * commercial ADC * PC based DAQ Resolution  10 um Efficiency  95 % Signal/Noise  10 = Good Detectors Eija Tuominen 26.09.2003

  10. RADIATION HARDNESS Proton irradiations: Similar results with gamma and neutron irradiations (results to be published) Eija Tuominen 26.09.2003

  11. CONCLUSIONS Czochralski silicon detectorswere processed and studied: Electrical performance: depletion voltage, leakage current, breakdown voltage - GOOD Detection performance: resolution, efficiency, signal-to-noise - GOOD Radiation hardness: EXCELLENT ! More info: Eija Tuominen, Doctoral Thesis (and its publications), ”Development of Radiation Hard Radiation Detectors”, to be publicly examined at 10.10.2003 at Helsinki University of Technology http://www.hut.fi/~emtuomin/Thesis.pdf Eija Tuominen 26.09.2003

More Related