Study of TAE stability vs. central shear and q(0)

Study of TAE stability vs. central shear and q(0). Document the scaling of TAE/EPM stability with: q(0) (mode structure) Density profile (mode structure) b (increased Landau damping of TAE) Acquire more information on the structure and amplitude of the modes: Upgraded soft x-ray system

arlo
Télécharger la présentation

Study of TAE stability vs. central shear and q(0)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Study of TAE stability vs. central shear and q(0) • Document the scaling of TAE/EPM stability with: • q(0) (mode structure) • Density profile (mode structure) • b (increased Landau damping of TAE) • Acquire more information on the structure and amplitude of the modes: • Upgraded soft x-ray system • Firetip?

  2. EPM/TAE induced losses seen in existing "near hybrid" scenarios • Need both: • Empirical information on parametric dependences of modes. • Ability to model effects on fast ion transport. • Study will focus on scans of: • q-profile shape, • Density profile shape, • beta • Paucity of data at high b largely reflects small dwell-time at highest b as well as the pathology of shots reaching high b.

  3. Previous experiment found suggestion of toroidal mode number scaling • At 0.5 MA, toroidal mode numbers from 1 to 6. • At 1.0 MA, toroidal mode numbers from 3 to 6. • Data not that clean… 0.5 MA 1.0 MA

  4. Run plan overview Goals: Determine q-profile, density profile shape dependence of stability, Look for Landau damping stabilization of TAE (b scan) (Reference shot tbd, based on early shots in campaign) ) Early H-mode, fast current ramp. (8 shots) • One, two and three sources, 2 shots each. • Delay third source, decouple b and q, 2 shots. B) Delayed H-mode (6 shots) • No current ramp pause, beam power scan, 2 shots each. • L-mode (He puffing) (6 shots) • One, two and three sources, 2 shots each.

  5. Run plan overview (cont.) D) Slower current ramp, delayed H-mode (6 shots) • Let qmin drop lower, decide based on amount of change seen in A-D. Or • Beam voltage scan (? shots) • Choose best case from A-D, drop beam voltage to 70 kV, then up or down 5 kV. Source A still at 90 kV, but on-time delayed until peak of MHD activity. • Also, consider how much time is left.