1 / 10

Activity Report on FAME Measurement MB2524: Snapback Analysis and Current Cycle Issues

This report details the activities conducted during FAME measurement MB2524, focusing on the standard LHC cycle at SM18 and the snapback analysis results. Key issues regarding the current cycle are highlighted, including the absence of a standard PELP and the use of a PLP from Iinj to IFT. Measurement sessions encompassing a current range from 2 kA to 11850 A are outlined, along with results from the snapback analysis, including sensitivity assessments and model error evaluations associated with Δb3 and ΔI3 metrics.

ashton
Télécharger la présentation

Activity Report on FAME Measurement MB2524: Snapback Analysis and Current Cycle Issues

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FAME measurement MB2524 Activity Report Louis Walckiers Giuseppe Montenero

  2. FAME measurement MB2524 • Outline • Measurements carried out • Issue concerning current cycle • Snapback analysis results

  3. FAME measurement MB2524 • Measurements carried out • 3 Standard LHC cycle at SM18 • (50 A/s p.c. , 10 A/s c.) • LHC runs from 2 kA up to 11850 A • (10 A/s p.c. , 10 A/s c.) • IFT-standard precycle at 11850 A • Next measurement sessions • IFT-(standard&LHC) precycle from 2kA up to 11850 A • dI/dt-standard precycle FT 11850 A • tPRE-(standard&LHC) FT 11850 • IPRE-(standard&LHC) FT 11850 • tFT- (standard&LHC) FT 11850

  4. FAME measurement MB2524 • Issue concerning current cycle • No Standard PELP was used • A PLP from Iinj up to IFT

  5. FAME measurement MB2524 Snapback analysis b3 Snapback analysis b3: fitting intervals

  6. FAME measurement MB2524 Snapback analysis results: Δb3

  7. FAME measurement MB2524 Snapback analysis sensitivity Δb3

  8. FAME measurement MB2524 Snapback analysis results: Δ I3

  9. FAME measurement MB2524 Snapback analysis sensitivity ΔI3

  10. FAME measurement MB2524 Snapback analysis: model error vs I3

More Related