An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UL Listed Fuel Cleaning and Maintenance Systems Manufactured by: CLINTON POWER

  2. FUEL MANAGEMENT SYSTEMS BY: CLINTON NEVADA 19 W. Brooks Ave. North Las Vegas, NV 89030 (702) 632-1366 Voice (702) 642-5276 Fax (866) 711-5900 Toll Free www.clintonnevada.com CLEAN FUEL MEANS RELIABLE EQUIPMENT

  3. WHY CLEAN FUEL? ACCORDING TO THE AMERICAN INSTITUTE OF DIESEL AND GAS TURBINE ENGINEERS: 50% of all Diesel Engine Generator Systems Will Fail Within The Lifetime Of The Plant 4% to 8% Of All Installations Will Fail Annually Even In The Nuclear Industry, A 2% Annual Failure Rate Is Considered The Standard

  4. FUEL CLEANING AND MONITORING SYSTEM

  5. INTRODUCTION • You will learn the importance of having clean, safe, stable fuel for today’s high tech power equipment • You will learn how unstable fuels actually are, and how quickly they deteriorate • You will learn practical and proven programs for good fuel quality management practices

  6. FACTS • FUELS CONTAMINATE ON THEIR OWN • CLIMATE AND WEATHER ADVERSELY EFFECT ALL FUELS • ALL ENGINE MANUFACTURERS ADHERE TO ASTM D975 AS A FUEL QUALITY STANDARD • EQUIPMENT WARRANTIES REQUIRE COMPLIANCE WITH ASTM D975

  7. OVERVIEW • IDENTIFY THE PROBLEMS • PROVIDE SOLUTIONS FOR THOSE PROBLEMS • COST JUSTIFY THE EXPENSES

  8. THE NUMBER ONE OPERATING EXPENSE AFTER INSTALLATION OF A STANDBY POWER SYSTEM IS FUEL

  9. IDENTIFICATION • THE FIRST STEP IS TO REALIZE THAT FUEL DETERIORATES AND CONTAMINATES NATURALLY • CLIMATE, WEATHER CHANGES, GEOGRAPHIC LOCATION, AND TIME ADVERSLY EFFECT THE STABILITY, EFFICIENCY, PERFORMANCE, AND QUALITY OF ALL FUELS

  10. CAN YOU TELL WHICH SAMPLE IS BAD?

  11. YOU CAN’T ALWAYS TELL VISUALLY WHETHER OR NOT FUEL IS HEALTHY AND CAN MEET ASTM D-975 STANDARDS • ONLY SEVERLY CONTAMINATED FUEL IS VISUALLY EVIDENT • YOU CAN HAVE A LABORATORY ANALYZE THE FUEL FOR ASTM D975 STANDARDS

  12. THE PROBLEMS THE NATURAL PROCESSOFORGANIC AND INORGANIC CONTAMINATION

  13. THIS IS A SEVERLY CONTAMINATED FUEL SAMPLE CONTAINING THE FOLLOWING:

  14. ORGANIC CONTAMINATION • FUNGI GROWTH • BACTERIA COLONIZATION • CLOUDING AND GELLING • GUMS AND RESINS • OXIDATION • CORROSION

  15. INORGANIC CONTAMINATION • WATER • CONDENSATION • RUST • SILICATES ANYTHING THAT IS SOLID, WHICH CAN’T BE BROKEN DOWN WITH A CHEMICAL, IS CONSIDERED TO BE AN INORGANIC SUBSTANCE

  16. OTHER AREAS OF CONCERN • UNRELIABLE QUALITY OF FUEL DUE TO REDUCED REFINERY QUALITY CONTROL • FOULED INJECTORS LEAK CAUSING MORE EXHAUST EMISSIONS (EPA STANDARDS?) • HIGH YEARLY MAINTENANCE COSTS • PERIODIC FUEL TANK CLEANING • RAPID ABRASIVE WEAR • PRODUCT REPLACEMENT AND REPAIRS

  17. RESULTS OF ORGANIC & INORGANIC CONTAMINATION • CLOGS FILTERS • STARVES EQUIPMENT • NON-COMBUSTIBLE FUEL • NON-PUMPABLE FUEL • EXCESSIVE EXHAUST • RAPID ABRASIVE WEAR • DETERIORATION

  18. EQUIPMENT MANUFACTURERS ALL ENGINE MANUFACTURERS DESIGN THEIR EQUIPMENT AROUND ASTM D975 FUEL QUALITY STANDARDS FOR PERFORMANCE, EFFICIENCY, AND ECONOMY WARRANTIES REQUIRE IT!

  19. NFPA 110 A NEW STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS DEFINING “INTELLIGENT STORED DIESEL FUEL MANAGEMENT”

  20. BASICS OF NFPA 110 • A STANDARD THAT STATES WITH DETAIL THAT: “FUEL SYSTEM DESIGN SHALL PROVIDE FOR A CLEAN SUPPLY OF FUEL TO THE PRIME MOVER” “FUEL MAINTENANCE FILTRATION AND TESTING SHOULD BEGIN THE DAY OF INSTALLATION”

  21. A-2 A-3 A-4 A-5 A-6 A-7 REFINERY FRESH FUEL GOOD WATCH CLOSELY – AGING HAS BEGUN ADVANCED AGING AND DETERIORATION BADLY AGED – NOT RECOMMENDED SEVERE AGING – DO NOT USE NFPA 110 RATING SYSTEM FOR FUEL:

  22. RELATED COMPONENTS EFFECTED BY FUEL QUALITY • FUEL TANK • FUEL TRANSFER SYSTEM • INJECTION PUMP • INJECTORS • CYLINDER WALLS • INTAKE AND EXHAUST VALVES • LUBRICATION SYSTEMS • COOLING SYSTEMS

  23. WE HAVE DEFINED THE PROBLEMS: • EXPLODES INJECTORS • RAPID ABRASION • UNRECOVERABLE PERSONNEL HOURS • LIABILITY TIME BOMB • DOWNTIME • EQUIPMENT REPLACEMENT

  24. CAN PROVIDE A PROGRAM TO COMBAT THE CONTAMINATION

  25. CONTROL • CONTROL IS ACCOMPLISHED BY REMOVAL OF CONTAMINATION & WATER FROM INSTALLING AN ULTRAPURE SYSTEM • ALL UNITS INLUDE OUR OWN MAGNETIC CONDITIONING FOR CLEANER AND MORE EFFICIENT BURNING FUEL • ADDITIONAL OPTIONS SUCH AS PRE-DAY TANK WATER SEPARATORS, TANK BREATHERS, AND SPILL RESPONSE KITS HELP SOLVE THE PROBLEMS AND MEET EPA REQUIREMENTS

  26. PREVENTS CONTAMINATION • A TOTAL REMEDIATION PROCESS • PROVIDES CLEAN, SAFE, RELIABLE FUEL

  27. PRODUCTS REQUIRED TO MAINTAIN A FUEL QUALITY MAINTENANCE SYSTEM: • ULTRAPURE FUEL CLEANING, MAINTENANCE & MONITORING SYSTEM • MAGNETIC FUEL CONDITIONER • DAY TANK PRE-CLEANER/SEPARATOR • TANK BREATHER • SPILL CONTAINMENT KIT TO MEET EPA REQUIREMENTS (EPA REGULATION 40 CFR 112)

  28. FUEL CLEANING, MAINTENANCE & MONITORING SYSTEM • BULK WATER SEPARATOR/STRAINER • ENTRAINED WATER REMOVAL • 10 MICRON FILTRATION • EMULSIFICATION REMOVAL • 2 MICRON FINE FINISH FILTRATION • FULLY AUTOMATED PLC TECHNOLOGY • COLOR TOUCH SCREEN GRAPHICS • COMMUNICATION WITH BUILDING & MANAGEMENT SYSTEMS • FIELD DIAGNOSABLE • ULTRAPURE IS UL LISTED

  29. MODEL 1A1

  30. FEATURES OF MODEL 1A1 • CAPABLE OF TREATING UP TO 30,000 GALLONS • PORTABLE • HEAVY DUTY DESIGN • LOW MAINTENANCE • ROI MEASURED IN MONTHS, NOT YEARS

  31. MODEL MX5

  32. FEATURES OF MODEL MX5 • MARINE GRADE BULKHEAD DESIGN • ALL STAINLESS STEEL COMPONENTS AND BRASS PLUMBING & FITTINGS • ON-OFF SWITCH • ENGINE ROOM MOUNTABLE OR DOCKSIDE MOUNTABLE

  33. USES OF MODEL MX5 • YACHTS • FISHING BOATS • WORK BOATS • TUG BOATS • BARGES • MARINAS

  34. MODELS 5A THROUGH 40A

  35. FEATURES OF MODELS 5A – 40A • UP TO FOUR 80,000 GALLON TANKS CAPACITY • COLOR TOUCH SCREEN CONTROLLER • 2 MICRON FILTRATION • REMOVES 99.9995% OF WATER IN FUEL • MULTIPLE SPILL DETECTORS EMBEDDED THROUGHOUT • ELECTRONICS ISOLATED IN SEPARATE DRAWER • 2-4 TANK MANIFOLD SYSTEMS MATCH MAIN HOUSING • MANIFOLDS PRE- PLUMBED AND ALL VALVES INSTALLED AT FACTORY, SHIPPED COMPLETE READY TO INSTALL • VARIETY OF INSTALLATION OPTIONS • EASE OF INSTALLATION

  36. FEATURES OF MODELS 5A - 40A (CONTINUED) • ELEGANT JOB SITE • VISUAL DATA INSPECTION • CLOSED LOOP • FULLY AUTOMATED OPERATION • CENTRALIZED MONITORING CAPABILITY • HIGH RELIABILITY • LOW MAINTENANCE • COST EFFECTIVE • ROI MEASURED IN MONTHS, NOT YEARS HOW DO YOU MEASURE CRITICAL SYSTEM FAILURES, ANYWAY?????

  37. What Makes Different? • Double Wall Construction, Inner Box Constructed Of Impervious PVC • Magnetic Conditioner Included As Standard • Electronics Enclosed In A Separate Compartment, Top Loaded For Ease Of Maintenance • Compatible With ModBus & Other Building Management Systems • May Be Monitored Remotely Or Locally • Field Diagnosable From Our Engineering Department Via Internet • Full Color Touch Screen Micro Processor Controlled • Multi-Tank Manifolds In Matching Enclosures To Main Units • Meets ASTM D-975 Section Regarding Removal Of Water by 99.9995% • Supply And Return Woven Stainless Steel Flex Connectors • Multiple 2 Stage Spill Detectors Indicate Any Fluid Present • UltraPure is UL Listed!