VOCALS

VOCALS. NSF C-130 Data Assessment Report. Resources. Project Documentation: www.eol.ucar.edu (RAF – Field Projects) Allen Schanot: schanot@ucar.edu Data Access: www.eol.ucar.edu (RAF – Data Access) Janine Goldstein: janine@ucar.edu

braith
Télécharger la présentation

VOCALS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. VOCALS NSF C-130 Data Assessment Report

  2. Resources • Project Documentation: www.eol.ucar.edu (RAF – Field Projects) • Allen Schanot: schanot@ucar.edu • Data Access: www.eol.ucar.edu (RAF – Data Access) • Janine Goldstein: janine@ucar.edu • Analysis Tools: www.eol.ucar.edu (RAF – Software) • Chris Webster: cjw@ucar.edu

  3. New Data Releasearchived 6/25/09 • No Changes to state, dynamic or thermodynamic variables • Updated CDP bin sizes & concentration • Updated PCASP bin sizes & concentration • Updated FSSP concentration • Special 2DC processing • Updated O3 & CO concentrations

  4. Position, Ground Speed & Winds • DGPS – most accurate • Unusually noisy signal due to interference • Separate data set • IRS – Schuler oscillation • Novatel GPS – Used as reference • Winds – • Use GPS corrected (WSC, WDC, etc) • IRS version for comparison (WS, WD, etc)

  5. Reference Altitude (ALTX) • GPS Altitude: variable satellite coverage • Data gaps • Pressure Altitude: non-std lapse rate • Constant surface pressure (1013.15) • DGPS most accurate but noisy this case • Used Radar Altimeter Data as reference • Accuracy decreases with increased altitude

  6. Reference Temperature (ATX) • OPHIR-III: less accurate / slower • In cloud as needed or at exit • Heated Rosemount: less accurate / slower • Used Unheated Rosemount • Minimal wetting in cloud • Fast enough for heat flux calculations

  7. Reference Humidity (PI Choice) • Chilled mirror most accurate • Slow (variable response tied to Td depression) • Overshooting at cloud boundaries • UV Hygrometer used in derived variables • Fast / suitable for moisture flux calculations • Flt-by-flt calibration against chilled mirror sensor • Some residual in flight drift (some unsat. Cloud legs) • Loss of accuracy at high altitude

  8. Surface Temperature (TSURF) • Derived from radiometric measurement RSTB • Adjusted for altitude based on mean PBL humidity • Not valid for cloud top temperatures due to unknown altitude separation. Use RSTB.

  9. CDP Cloud Droplet Data • Optical window heater failure led to mid project change in probe calibration (rf04 / rf06) • Switched to 2 stage bin size calibration • Bin shift checked with flt-by-flt pollen test • Data updated in June release to archive

  10. PCASP Aerosol Data • Collaborated with Univ. of Wyoming on bin sizing and sample flow calibration • Bin 1 data removed from concentration total due to excessive noise. • Data updated in June release to archive

  11. 2DC Precipitation Data

  12. RAF FSSP-100 Cloud Probe Data • Probe modified to reduce droplet shattering • Excessive noise in smallest bins • First bin 6 or 8 in CONCF calculation • Raw data matrixes intact • Probe changed to std model between rf10 & rf11 • Noise reduced to normal • First bin 2 in CONCF calculation

  13. User Supplied Data • Drexel SO2 & DMS – merged • RAF Chemistry (O3 & CO) – updated to final product • CVI – updated to final product • Wyoming CN – updated to final product • Wyoming CCN - products separate in archive • Hawaii CN – preliminary / final products separate in archive • Hawaii non-CN aerosols - products separate in archive • Fast FSSP - products separate in archive • WCR & WCL - products separate in archive • Microwave Radiometer - products separate in archive • RAF GNI – products separate in archive