SlideServe
Menu
Préférences
© SlideServe · v2026

Filter & Transfer Function

brent-castillo avatar
12 diapositives · 363 Views · Nov 13, 2014

This document provides a comprehensive overview of filter types in electrical circuits, focusing on the impedance (Z1, Z2) as a function of frequency and resonance effects on current and voltage. It also reviews key concepts of AC power, including average power, reactive and apparent power, and the significance of power factor in circuits with inductance and capacitance. Detailed examples illustrate power calculations for motors with varying parameters and frequency adjustments, emphasizing the importance of optimizing power factors for electrical design.

Filter & Transfer Function - slide 1
01 / 12Filter & Transfer Function
1 / 17

Télécharger la présentation

Filter & Transfer Function
Une image / un lien ci-dessous est fourni (tel quel) pour télécharger la présentation

Politique de téléchargement : le contenu du site vous est fourni TEL QUEL pour votre information et votre usage personnel ; il ne peut être vendu, concédé sous licence ni partagé sur d’autres sites sans l’accord de son auteur.Le contenu vous est fourni TEL QUEL, pour votre information et votre usage personnel uniquement. Téléchargez la présentation en cliquant sur ce lien. Lors du téléchargement, si vous ne parvenez pas à télécharger une présentation, l’éditeur a peut-être supprimé le fichier de son serveur.Pendant le téléchargement, si vous ne parvenez pas à obtenir une présentation, le fichier a peut-être été supprimé par l’éditeur.

F I N

Plus de contenu associé

Transcription de la présentation
  1. Z1 Vout Vin Z2 Filter & Transfer Function To determine filter type, look how HV as a function of frequency Z1 and Z2 could include multiple components

  2. RLC at Resonance • At resonance: • current is max. • Zeq =R • current and voltage are in phase. • the higher Q, the narrower the resonant peak.

  3. Exam II Review: AC Power Average power rms value • The average ac power (Pav) is the power dissipated on the load resistor. • 0cosq1, dependent on the complex load. • ideal power factor: cosq =1, Z=R, pure resistive load

  4. AC Power: instantaneous and average power

  5. Complex Power • real power Pav(unit: watts): power absorbed by the load resistance. • reactive power Q (unit: volt-amperes-reactive, VAR): exchange of energy between the source and the reactive part of the load. No net power is gained or lost during the process. Q=QL-QC, if Q<0, the load is capacitive, Q>0, the load is inductive • Apparent power: |S|=|Vrms||Irms| (unit: volt-amperes, VA): computed by measuring the rms load voltage and currents without regard for the phase angle.

  6. Example 7.8, P345: power factor correction

  7. Transformer Transformation of Voltage: Transformation of Resistance:

  8. Residential Wiring GFCI

  9. Example: Midterm 1998 An electrical engineering major has designed and constructed a motor for your sophomore design project. It has been wound with an inductance of 16 mH and a resistance of 3.0 ohm. You had specified that it be optimized for the best possible power factor at 60 Hz; consequently, a 354 microFarad capacitor was added in parallel with the motor, as shown below. a. Operated at 120 V, what is the current through the motor when operated at 60 Hz? b. What power is delivered by the voltage source? c. What power is dissipated by the motor? Your complete project was so innovative that your engineering professor entered it in an international competition. You arrive in Germany for the competition before remembering that the line frequency there is 50 Hz. d. What is the power factor of this circuit at 50 Hz? e. What capacitance do you need to replace 354 mF capacitor in order to correct the power factor back to unity?

  10. Example Cont. a. Operated at 120 V, what is the current through the motor when operated at 60 Hz? b. What power is delivered by the voltage source? d. What is the power factor of this circuit at 50 Hz? e. What capacitance do you need to correct the power factor back to unity? Note: you calculate S only on the motor part! Negative just means Capacitor

  11. Example 3: 1st Fall 199 • An electrical engineering firm has designed a motor for your sophomore design project. You specified that it should be wound with an inductance of 16 mH and a resistance of 3.0  ohm. You had specified that it be optimized for the best possible power factor at 60 Hz; consequently, a 354 mF capacitor was added in parallel with the motor. Unfortunately the motor was actually wound with an inductance of 61 mH and a resistance of 30 ohm because of typographical errors in the FAX to the motor manufacturer. • What power is delivered by the voltage source? • What power is dissipated by the motor? • What capacitance do you need to replace 354 mF capacitor in order to correctthe power factor back to unity?

  12. Example Cont. a. What power is delivered by the voltage source? b. What power is dissipated by the motor? d. What capacitance do you need to correct the power factor back to unity?