An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Local Supports for Inclined Layout: CERN Update D. Alvarez Feito CERN EP-DT-EO CERN, November 2016

  2. Local Support Designs for Inclined Layouts • Stave/Longeron Approach • Conservative approach (two pipes per module) • Intermediate approach (single pipe per module, soldered interfaces) • Aggressive approach (single pipe, glued interfaces) • Tilted Rings (e.g. CMS)

  3. Aggressive approach: Curly Pipe Design • Design solution developed for SLIM v3.0 • Compatible with common inclined effort (“Aggressive Version”) • Main Objectives: • Radical reduction of the cell mass while meeting TFM requirements • Eliminate the need for solder interfaces • Minimise the effect of the Ti pipe on the positioning of the modules (e.g. introduce local CFRP supports) • Minimise ΔT within the module • Facilitate module loading in “flat” configuration • Allow for re-workability/replacement of defective modules (i.e. modularity).

  4. Inclined Section: Principle (I) • Thermal Management • Curly Pipe (i.e. smooth 3D loops in the cooling line) • Increase usable pipe surface • Reduce distance from pipe to sensor • Introduce flexibility in pipe • Independent of “tilt” angle • Cooling plate • “Machined” graphite plate • Flat TPG (reinforced if needed) • Loading on flat surface • Local CFRP support for positioning and stability • DOES NOT PLAY ANY THERMAL ROLE (thus, not included in thermal FEA) • Support two adjacent tilted modules (minimise #parts, increase stiffness) • Define positioning of cooling plate (locator system, e.g. pins, ruby balls) • Constrain the pipe (epoxy glue, not conductive)

  5. Inclined Section: Principle (II) Support Structure (Longeron + Tilted Support + Curly Pipe) Module Cell (Module + cooling plate) Cooling Plate (TPG, graphite) Silicon Sensor (Includes machined holes/locators) Conductive glue Loop Pipe (glued to support/longeron) CFRP Support (glued to longeron) CFRP support includes locators for module cell (pins, ruby spheres) Longeron

  6. Inclined Section: Principle (III) Final Assembly (Support Structure + Module Cell) Gap Filler/TIM (Thermal contact between pipe & plate) • Module cell fixed to support structure: • Gap filler/TIM for thermal contact • Removable glue (e.g. SE4445) for securing positioning /pressure (NO THERMAL ROLE) • Matching locator system between cooling plate and CFRP local support Removable glue for positioning (e.g. SE4445, no thermal role) Module Cell (Cooling plate + Sensor assembly)

  7. Inclined Section: Thermal Performance Global TFM (˚C∙cm2∙W-1) • Graphite plate (porous or iso-graphite) • Example: Porous graphite plate (ρ=1000kg/m3, K=86Wm-1K-1, 0.36g) • Flat TPG plate (see next slides) • No machining required • High in-plane thermal conductivity → Lower ΔT within the module Module ΔT~7˚C

  8. Thermal Performance: TPG Cooling Plate • FEA Assumptions: • Module size: 40 x 19 x 0.35 mm • TPG Size: 38x19 mm (thickness between 0.1-0.6mm) • Heat flux: 0.7W/cm2 • HTC inside the pipe: 8000 W∙m-2∙˚C-1 • Thickness of Gap filler/TIM between pipe and TPG plate: 0.25mm • No environmental convection/radiation • No thermal contact losses • No contribution from local support or additional CFRP reinforcement • Material properties:

  9. Thermal Performance: TPG Cooling Plate Global TFM (˚C∙cm2∙W-1) • Full contact with the pipe loop: TPG 0.3mm thick

  10. Thermal Performance: TPG Cooling Plate α • Partial contact with the pipe loop: • Section of the gap filler removed to reduce ΔT within the module

  11. Thermal Performance: TPG Cooling Plate α • Partial contact with the pipe loop: • Section of the gap filler removed to reduce ΔT within the module

  12. Local CFRP Support • Glued to truss • Incorporate groove to position and glue the pipe (“buried” pipe) • Incorporates locator system (e.g.pins,ruby balls) to position module cell • Ideally, it would support two tilted modules from adjacent rows • Ongoing design optimisation (geometry, layup, longeron compatibility) • Prototyping to follow (3D printed mould) Not realistic geometry (shown only for illustration purposes)

  13. Local CFRP Support • Glued to truss • Incorporate groove to position and glue the pipe (“buried” pipe) • Incorporates locator system (e.g.pins,ruby balls) to position module cell • Ideally, it would support two tilted modules from adjacent rows • Ongoing design optimisation (geometry, layup, longeron compatibility) • Prototyping to follow (3D printed mould) Not realistic geometry (shown only for illustration purposes)

  14. Local CFRP Support • Open design + stiffening rib • Tubular design (N.Geffroy) Not realistic geometry (shown only for illustration purposes)

  15. Flat Section: Principle (I) • Thermal Management: • Single, straight pipe • Cooling TPG Plate (machined with longitudinal groove) • “Machined” TPG plate (reinforced if needed with thin CFRP plies) • Thermal contact with pipe via removable interface (gap filler /TIM) • NO soldered interface • Loading on flat surface • Local carbon support for positioning and stability • DOES NOT PLAY ANY THERMAL ROLE (thus, not included in thermal FEA) • Support two adjacent flat modules (minimise #parts, increase stiffness) • Define positioning of cooling plate (locator system, e.g. pins, ruby balls) • Constrain the pipe (epoxy glue, not conductive) • CFRP “Ribbon” or “Graphite Block”

  16. Flat Section: Principle (II) Module Cell (Module + cooling plate) Module Machined TPG Support Structure (Longeron + Tilted Support + Pipe) Conductive glue (TIM) CFRP Supports (glued to longeron) Ti Pipe (glued to CFRP supports)

  17. Flat Section: Principle (II) Gap filler/Phase Change TIM (thermal contact Ti-TPG) Removable glue for fixation (e.g. SE4445, no thermal role) Module Cell (positioning via locator system in supports/cold plate)

  18. Thermal Performance: TPG Cooling Plate Global TFM (˚C∙cm2∙W-1) • Example (0.4mm thick plate): Module ΔT (˚C)

  19. Thermal Performance: TPG Cooling Plate • TPG dimensions can be selected to match the TFM requirements for each layer while minimising the cell mass and the ΔT within the module. • Parametric study Module Size (W,L): 38x40mm

  20. Thermal Performance: TPG Cooling Plate • TPG dimensions can be selected to match the TFM requirements for each layer while minimising the cell mass and the ΔT within the module. • Parametric study Module Size (W,L): 38x40mm

  21. Thermal Performance: TPG Cooling Plate • TPG dimensions can be selected to match the TFM requirements for each layer while minimising the cell mass and the ΔT within the module. • Parametric study Module Size (W,L): 38x40mm

  22. Thermal Performance: TPG Cooling Plate • TPG dimensions can be selected to match the TFM requirements for each layer while minimising the cell mass and the ΔT within the module. • Parametric study Module Size (W,L): 38x40mm

  23. Prototyping Activities

  24. ‘Curly’ Pipe: Initial Thermal Tests • Very preliminary thermal tests (stainless steel pipes) • Comparison between straightpipe and line with loops (same length) • Homogenously distributed heat load using pipe resistivity (50W) • CO2 inlet temperature set to -20°C N. DIXON -15.3°C -15.1°C -14.8°C -15.4°C -16.0°C

  25. ‘Curly’ Pipe: Latest Thermal Tests • Assess performance of the ‘curly’ pipe for different phi positions and identify potential problems • Stainless steel pipe with 5 loops and simplified module cells: • Al cooling plate with machined groove (gap filler + clamp) • Kapton heater • NTC at the furthest corner N. DIXON; R. GOMEZ Seehttps://indico.cern.ch/event/571640/ for the results

  26. Curly Pipe: New Prototypes • 4 new prototypes produced by external company (stainless steel, OD4mm/ID2mm) • Modified geometry proposed by the company to ease manufacture • Plan: • Assess new geometry from the fluidic standpoint (i.e. CO2 behaviour) in different Φ positions • Measure Δp to validate CO2 simulations (COBRA) • Measure HTC? • If results are positive, we will launch prototyping campaign with Ti pipes (new jigs will be required, so we should converge to a suitable pipe size beforehand!!!)

  27. EP-DT Thermal Set-up: Upgrade • Monitor CO2 vapour quality

  28. Support Structures: Longerons • Truss Longeron: • Four new 1m-prototypes of the truss longeron (“hybrid” construction) • Production rate: 1/day (including all preparation steps) • Shell Longeron: • In-house production of shell longeron following procedure developed at Composite Design F. BOYER