This document provides a comprehensive list of signals to be readout from the Linac Test Area (LTA) instrumentation, including signals related to beam line elements, beam properties measurements, cryogenics, hydrogen experiment absorbers, RF and solenoid experiments. It also includes a time schedule and relevant images.

bwinter
Télécharger la présentation

Linac Test Area Instrumentation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Linac Test Area Instrumentation D. Errede, M. Haney (UIUC) M. Shea (FNAL) MuCool Feb 6, 2002

  2. Problem: What are the signals to be readout from the LTA? • Beam Line (Carol Johnstone) • Beam Properties Measurements (CJ) • Cryogenics (Barry Norris) • A. H2 • B. He • Experiment • A. Absorbers (Mary Anne Cummings, Edgar Black) • B. RF Cavities (Al Moretti) • C. Solenoid (Al Moretti)

  3. Beam Line Elements # signals • 750 KeV Chopper 1 • dipole magnets currents 5 • quad magnet currents 13 • stripping foil 1 • collimater positions - 2 units 8 • ion chamber 1 (in front of beam dump)

  4. Beam Properties Measurements # signals • Tune Parameters ? data set • Beam Position Monitors 20-40 • Toroid Beam Current Monitor 1 (slow response) • Fast Beam Current Monitor 1 (fast response) • Beam Loss Monitors 5-10

  5. Cryogenics # signals • Helium • inlet temp (carbon) 1 • outlet temp (carbon) 1 • inlet temp (platinum) 1 • outlet temp (platinum) 1 • inlet pressure 1 • outlet pressure 1 • He level 2 • N2 level 1 • solenoid coil temperature (platinum) 4

  6. inlet temp(carb) 1 outlet temp(carb) 1 inlet temp (plat) 1 outlet temp (plat) 1 temperature other 6 inlet pressure 1 outlet pressure 1 pump delta press 1 H2 supply press 1 H2 vent press 1 H2 vent pipe press 1 cryo vacuum press 2 pump status (run/not) 1 pump voltage 1 pump current 1 pump speed 1 heater voltage 1 heater current 1 heater power 1 beam permit 1 hazardous gas 10 O2 deficiency hazard 8 Cryogenics Hydrogen

  7. Experiment - Absorber #signals • temperature 12 • pressure transducers see under cryo • photogrammetry (??) 2 • laser occlusion sensor (??) 4 • piezo vibration sensors 2 • strain gauges 2 • bolometry ?? • O2 sensors 3per each of 5 flanges 15 • H2 sensors on exhaust line 10 • CCD camera 2 images • MICE channels ??

  8. Experiment - RF, Solenoid #signals • solenoid current 1 • rad level on chipmunks 10? • Cavity forward power 1 • cavity reflected power 1 • cavity RF level (E-field?) 2 • cavity vacuum level 2 • timing channels 10?

  9. Picture of cryo/absorber assembly

  10. Time schedule