Power Electronics

Power Electronics. Small-signal converter modeling and frequency dependant behavior in controller synthesis. by Dr. Carsten Nesgaard. Agenda. Small-signal approximation. Voltage-mode controlled BUCK. Converter transfer functions  dynamics of switching networks.

canavan
Télécharger la présentation

Power Electronics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Power Electronics Small-signal converter modeling and frequency dependant behavior in controller synthesis by Dr. Carsten Nesgaard

  2. Agenda Small-signal approximation Voltage-mode controlled BUCK Converter transfer functions  dynamics of switching networks Controller design (voltage-mode control) Discrete time systems Measurements

  3. Small-signal approximation Advantages of small-signal approximation of complex networks: An analytical evaluation of equipment performance An analysis of equipment dynamics Stability Bandwidth A design oriented equipment synthesis The linearization of basic AC equivalent circuit modeling corresponds to the mathematical concept of series expansion.

  4. Small-signal approximation Drawbacks of small-signal approximation of complex networks: Limited to rather low frequencies (roughly fS/10) Inability to predict large-signal behavior Transients High frequency load steps Calculation complexity increases quite rapidly

  5. Not included in ‘Fundamentals of Power Electronics’ SE. Voltage-mode controlled BUCK Basic BUCK topology with closed feedback loop

  6. Voltage-mode controlled BUCK Converter waveforms:

  7. AC modeling Converter states: 0 < t < dT: dT < t < (1 – d)T KCL: KVL:

  8. DC and 2nd order terms are removed from the equations to the right. AC modeling Averaging and linearization (in terms of input and output variables): Inductor equation: Capacitor equation (same for both intervals): Input current equation:

  9. AC modeling Resulting AC equivalent circuit: DC transformer relating input voltage and inductor current, thus behaving ‘almost’ like a real transformer.

  10. Canonical AC model Rearranging the AC equivalent circuit found on the previous slide by the use of traditional circuit theory a universal model can be established: A similar model applies to a wide variety of other converter topologies. In Fundamentals of Power Electronics SE a table containing coefficients for the different sources can be found.

  11. A : State matrix B : Source matrix E : Control matrix F : Feedback matrix I : Identity matrix Q : Feed forward matrix State equation: M : Output-state-matrix N : Output-source-matrix d : Control variable u : Source variable Control equation: x : State variable y : Output variable Output equation: Converter transfer functions Basic control system

  12. Open loop transfer function: Closed loop transfer function: Converter transfer functions Opening the loop and rewriting the system equations the following trans-fer functions can be obtained:

  13. Inductor current x1 Capacitor voltage x2 State-space averaging State variables: By definition the following apply: Output variable y (dependent) Source variable u (independent) In order to contain past information all variables are functions of time

  14. The use of linearization requires: Insertion into the state equation results in: State-space averaging Averaging the equations previously found results in the following non-linearized matrices:

  15. Comparing the above A matrix with the non-linearized A’ matrix found on the previous slide, it can be seen that no changes have occurred. State-space averaging The averaged and linearized matrices can now be identified:

  16. Collecting terms in accordance with the control equation, and realizing that multiplication by ‘s’ in the frequency domain is the equivalent to differentiation in the time domain, the matrices F and Q can be identified: and Since feedback is the only means of converter control applied, Q is (as expected) zero. State-space averaging Averaging and linearizing the control variable d (PWM controller) in terms of state variables gives the following relation: is the sawtooth peak voltage is the EA gain, ‘a’ factor and comp.

  17. 0 1/L 1/RLOADC -K/VP 1 State-space averaging Summarizing the voltage-mode controlled BUCK matrices:

  18. Stability Nyquist stability requirement for closed loop systems: Prh(GCL(s)) = Prh(GOL(s)) +  = 0 Where: Prh = number of right half-plane poles  = number of times the Nyquist contour of the open- loop transfer function circles the point (-1,0) GCL = Closed-loop transfer function GOL = Open-loop transfer function Minimum open-loop transfer function gain margin: 6 - 8 dB Minimum open-loop transfer function phase margin: 30- 60

  19. Circuit data: L = 300 H C = 69 F RESR = 0,2  ILoad,m = 1 A U1 = 12 V y2 = 5 V IL = 0,2 A f = 50 kHz Additional data: Vp = 2,45 V a = 0,5 Voltage-mode controlled BUCK

  20. Voltage-mode controlled BUCK A plot of the open-loop transfer function is shown below (K = 1):

  21. Voltage-mode controlled BUCK A 3D plot of the converter filter transfer function is shown to the right. Note: The zero caused by RESR increases the phase (green curve) as a function of frequency and RESR. Unfortunately due to the same zero the filter attenuation drops (red curve).

  22. Compensation PI-comp. Lag-comp. PD comp. Lead-comp. A PI-Lead-comp. (PID) will be used in this presentation

  23. Compensation Widely accepted error amplifier configuration: Pole at f = 0 for increased DC gain Pole at fESR for compensation Double zero at resonance peak for increased phase margin

  24. -20 dB/dec +20 dB/dec 0 dB/dec fC 4.0 kHz  56,1 0 dB/dec -40 dB/dec -20 dB/dec Red : Converter transfer function Blue : Compensation transfer function Compensation Compensator and converter transfer functions: Amplitude: Phase:

  25. Voltage-mode controlled BUCK Using the previously derived matrices an expression for the input impedance Zin can be established:

  26. Voltage-mode controlled BUCK A plot of the open-loop transfer function during Discontinuous Conduction Mode (red curve) and EA compensation (blue curve) DCM reduces the converter transfer function to a first order system, since the time derivative of the small-signal inductor current is zero and thus disqualifies the inductor current as a state variable.

  27. At the sampling instants: Thus, the dynamics of the two systems are identical at the sampling instants: Discrete time systems Transient response and the relationship between the s-plane and the z-plane: Discrete time: Continuous time: Inserting into the expression to the left, it can be seen that the continuous time stability requirement maps onto the z-plane in form of the unit circle.

  28. Discrete time systems Arithmetic and operations: • Integration and differentiation • Plotting the frequency response • Tustin’s rule • Sampling rate

  29. Discrete time systems Plot of the discrete compensation transfer function: Cont Continuous time Disc_1 Discrete time with sample frequency = 50 kHz (no prewarping) Disc_2 Discrete time with sample frequency = 100 kHz (no prewarping)

  30. Measurements Below is a comparison of the predicted continuous time loop gain, predicted discrete time loop gain and an actual measurement of the loop gain: GH Continuous time GD_2 Discrete time with sample frequency = 50 kHz (no prewarping) Meas Actual measurement

  31. Measurements The same transfer function as before, but during Discontinuous Conduction Mode: GH Continuous time Meas Actual measurement