1 / 4

Ultrasonic Testing Machine India

Canopus Instruments is Concrete Ultrasonic Testing Equipment and machine Manufacturers in India. They also supply ultrasonic testing equipment.

Télécharger la présentation

Ultrasonic Testing Machine India

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SIGNAL CONDITIONING & IS0LATION SIM - µ 3.0 – AC Series ISO 9001:2008 Certified Powerline Converters for AC Voltage & Current Signals SIM - µ 3.0 – AC Series Features: Input Options: AC Current: 0 – 1A, 0 – 5A, 0 – 8A. AC Voltage: 0 – 100V, 0 – 300V, 0 – 500V. Industry Standard Output: 1-5V, 0 - 5V, 0 - 10V, 4-20mA, 0 - 20mA. Power supply options: 24VDC 90 - 270VAC, 50Hz/60Hz or 100 – 250VDC Reduced heat loss due to improved Power Supply efficiency. Response Time <100mSec. Low Noise & Low drift for long term stability. 2 KV 3 Port Isolation. Performance guaranteed from 0 -55 Deg C. Single, Dual & Triple Isolated Output versions available. Upto 8 nos. of Isolated Outputs can be generated using back-plane expansion.

  2. SIGNAL CONDITIONING & IS0LATION SIM - µ 3.0 – AC Series ISO 9001:2008 Certified Overview: The AC Voltage Isolators ( 3 Port ) can be used in Potential Transformer (PT) signal conditioning applications. The AC voltage output (e.g. 0– 100 / 300 / 500 VAC) of a PT can be directly connected to the input of the unit which provides isolated analog DC voltage or current output that is linearly proportional to the input. The AC Current Isolators ( 3 Port ) are used in Current Transformer (CT) signal conditioning applications. The AC current output (e.g. 0 - 1 Amp. or 0 - 5 Amp.) of a CT can be directly connected to the input of the unit which provides isolated analog DC voltage or current output that is linearly proportional to the input This enables ease of data transmission as well as interfacing to standard measuring devices such as Analog input modules of PLC & DCS systems. These units are used in AC Power line voltage / AC Power line current measurement and monitoring applications. The unit provides 3 -port 2 KV isolation between input, output and supply. Multiple Isolated Outputs can also be obtained to suit application requirement. The module options are available which operate on 24VDC supply and on Universal AC/DC supply voltages of 90 - 270 V AC, 50/60 Hz or 100-250VDC. The use of switching power supply improves power efficiency and reduces internal heat losses of the module. These units are compact, light weight and are suitable for mounting on 35 mm DIN std. rail as well as on base plate. Address: #2 & 3, ‘Vishwas’, Karnik Road, Off. Murbad Road, Kalyan (W) 421 301, Maharashtra, INDIA. Tel: +91-251-2322576 / 2203389 Telfax: +91-251- 2325849. Email:marketing@canopusinstruments.comWebsite: www.canopusinstruments.com

  3. SIGNAL CONDITIONING & IS0LATION SIM - µ 3.0 – AC Series ISO 9001:2008 Certified General Specifications: 1. Power Supply 5. Ambient conditions Design as per 24VDC Supply Climatic rating As per IEC 60068 - 2-30 Power Supply Voltage Typical : 24 V DC Tolerance: 18 –36VDC Operating temp. -10 to + 60 Deg C Power Supply Current 200 mA ( max.) . Storage temp. - 20 to + 85 Deg C 2 Watt (Single Output type) 4 Watt (Dual Output type) 5 Watt (Triple Output type) Power Consumption (Approx.) Relative Humidity R.H = 93 + 3 % , Design as per Vibration Standard Frequency : 10 – 150 Hz Displacement : 0.75 mm or acceleration : 1.5 g, No. of sweep/axis : 20, Axis : 3 ( x, y & z ) Universal Supply Power Supply voltage 90 –270VAC; 50/60Hz OR 100-250VDC Design as per Shock Standard 40g. 11 ms, half sine pulse & 18 shocks, 3 shock in each sense. As per IEC 61010-1 Power Consumption 9 VA Approx. 2. Input signal AC Current AC Voltage 0 – 1A , 0 - 5A , 0 – 8A 0 -100V, 0-300V,0-500V Max. permissible Limit For Current Input : 10 A AC For Voltage Input : 750 VAC 6. Safety Isolation Level 2KV RMS Between I/P, O/P & Supply 7. Installation Data Between I/P & O/P For Current Input For Voltage Input CT Burden < 0.5VA Impedance >1 M Ohms 3. Output signal Cooling Forced cooling not required DC current or DC voltage 0 –20 mA or 4 – 20 mA or 0-10V DC Single Output : Any one of above Dual Output : Any two of above Triple Output : Any two of above Material of housing Polyamide PA 6.6 V0 ( UL 94 ). Green Colour Mechanical Size For Single Input Single Output W – 22.5 X H - 100 XD- 110 mm Mounting Mounting position For Single Input Dual/Triple Output W – 45 X H - 100 XD- 110 mm 35 mm DIN Rail Mounted. Horizontal OR Vertical. Output limit For Current Output 30 mA For voltage Output +/-15 V Max. load resistance For Current Output < 500 Ohms For Voltage Output > 1K Ohms Response Time Typically : <100 ms Connectors Connection Green Colour , 5.08 mm Pitch , 16 A Screw terminal suitable for 0.2 to 2.5 mm standard wires 4. Accuracy data At 25 0 C ambient Temp. Limits over Temp. range Drift Temp. coefficient Linearity +/- 0.25 % of FS +/- 0.5% of FS + 0.005% / Deg. C/ 0.1 % of FS Address: #2 & 3, ‘Vishwas’, Karnik Road, Off. Murbad Road, Kalyan (W) 421 301, Maharashtra, INDIA. Tel: +91-251-2322576 / 2203389 Telfax: +91-251- 2325849. Email: marketing@canopusinstruments.comWebsite: www.canopusinstruments.com

  4. SIGNAL CONDITIONING & IS0LATION SIM - µ 3.0 – AC Series ISO 9001:2008 Certified Ordering Info: No. of O/P’s O/P Signal Range (Extension required only when 2nd & 3rd O/P’s are available) µ3.0 I/P Signal O/P Signal Supply I/P Signal Range µ3.0 I/P O/P XX XX XX XX µ3.0 Iac V I 24VDC : 2D 90-270VAC : U OR 100-250VDC 0-1A : 01 0 -5V : 05 0-10V :10 4-20mA :42 0-20mA :20 V : 2nd O/P V : 0-10V 0-5A: 05 2V : 2nd O/P V: 0-10V 3rd O/P V: 0-10V 0 -8A :08 I : 2nd O/P I: 4-20mA 0 -100V : 100 Vdc 2I : 2nd O/P I: 4-20mA 3rd O/P I : 4-20mA 0 -300V : 300 VI : 2nd O/P V: 0-10V 3rd O/P I: 4-20mA 0 -500V : 500 Address: #2 & 3, ‘Vishwas’, Karnik Road, Off. Murbad Road, Kalyan (W) 421 301, Maharashtra, INDIA. Tel: +91-251-2322576 / 2203389 Telfax: +91-251- 2325849. Email:marketing@canopusinstruments.comWebsite: www.canopusinstruments.com

More Related