An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Lead(208Pb) Radius Experiment:PREX Elastic Scattering Parity-Violating Asymmetry E = 1 GeV, Z0 : Clean Probe Couples Mainly to Neutrons FN (Q2) Applications : Nuclear Physics, Neutron Stars , Atomic Parity, Heavy Ion Collisions Ran Mar 19 – June 20, 2010 ( Dany Page ) Obtained 20% statistics Main problem: radiation degradation of vacuum seals and HRS controls systems Nuclear Theory Accomplishments : • Statistics limited, negligible noise • Pb target ran at 50 uA with last 3 days at 70 uA • Precision Compton and Mollerpolarimetry (1.5%) • Thin quartz detector for high rates (1 GHz) • Septum magnet at high luminosity • <Q2>: low-current cavity monitors, GEM detectors PREX : density -dependence of the symmetry energy. Nuclear physics community very interested in this !

  2. PREX Run-averaged asymmetry placed at “1.0” (approx ppm) for presentation. Physics Asymmetry vs Data Set Good chi-square: data are statistical All data. Sign flips removed (product of Wien flip and IHWP flip) “Blinded” Asymmetry ½ our data; the sign flips with Wien x IHWP flip “slug” ~ 1 day Lessons of PREX Plan to release results at April 2011 APS meeting. Expect dRN / RN ~ 2.5% ( Ultimate goal : 1% ) Proposed new measurements with fixes to vacuum system and shielding • Last 3 days @ 70 uA promising : 125 ppm detector noise • @15 Hz equiv. flip rate • Raster synched to flip rate to reduce noise due to target. • Transverse asymmetry AT < 2 ppm

  3.  Apparatus was assembled correctly at the 1 mm level.

  4. Problem: Missing acceptance. Q2 pushed high Kiad’s HAPLOG 2450: We were underbending by 5 mrad, need to run 760 A septum (was 729 A) Non-optimal Q2

  5. R. Michaels, Oct 2010 (thanks, Bogdan W.) Need GEANT simulations to design the shielding Need engineering and design support.

  6. Using HAMC (Monte Carlo) to predict a future running point. How good is HAMC ? 1 - HRS Keep apparatus same Run septum @ 775 A Ebeam = 925 to 1000 MeV

  7. Future Run of PREX

  8. Lead / Diamond Target Seem to melt after ~1 week We melted two targets A third ran for 4 days at 70 uA. Strategy ? Run with ~12 targets 6 lead/diamond 6 lead/carbon (carbon more robust)

  9. PREX: Things to Do / Conclusions dRN/R N = 1 % • 12 GeV run ? Thinking: Oct – Dec 2013 Hall A Commissioning. • Asking for 8 to 10 weeks. Go to PAC in Dec 2011. • Assuming approval : • In ~12 month period prior to experiment: • Re-design beamline to withstand radiation & thermal cycling. • Design radiation shielding to protect equipment. • Minor mods to targets (try Pb/carbon, add more targets).