1 / 14

Creosote - 43 Years of Experience as a Ground Contact Preservative

chelsea
Télécharger la présentation

Creosote - 43 Years of Experience as a Ground Contact Preservative

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Creosote - 43 Years of Experience as a Ground Contact Preservative

    2. Presentation Overview History & Background Creosote Types & Attributes Visual Grading Scale Visual Grading Examples Performance Summary Conclusion

    3. History & Background Established 1958 Located on the Blessing Plantation - just North of Charleston, SC Severe deterioration zone per AWPA Standard C4 Survived Hurricane Hugo in 1989!

    4. History & Background Cooperative test between 4 creosote suppliers: Allied Chemical US Steel Koppers Industries Bernuth Lembcke Co.

    5. History & Background 7 ft. Southern yellow pine posts 11 types of creosote / creosote blends installed Retention targets of 4, 6 & 8 pcf.

    6. Creosote Types Creosotes designated A, C, D, F and G were straight run distillates. Creosotes designated B and E contained 2% pentachlorophenol. Creosotes designated H and I were 70/30 solutions meeting the 1958 P2 Standard (not available). Creosotes solutions J and K were 50/50 solutions meeting the 1958 P3 Standard.

    7. Selected Attributes of Creosotes Creosote types A & D had the lowest residue at 355F, with A being the most volatile. Type G is the closest to the blend of P1/P13 used today. Type F meets the current P2 Standard.

    8. Visual Grading Scale 10 indicated a sound post 9 rating allowed surface softness up to 1/8 deep 7 rating indicated general surface decay, up to 1/4 deep. 4 rating indicated decay exceeding 1/2, and 0 rating indicated failure - post easily broken.

    9. Visual Grading Examples

    13. Conclusions This test represents the longest continuous evaluation of creosote treated posts 2 creosote blends, G & F, are exhibiting excellent performance and most closely represent current P1/P13 and P2 Standard products. Creosote has been demonstrated to provide outstanding long term protection in harsh, ground contact applications