An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Particulate Control-2Fabric FiltersParticulate Scrubbers Lecture notes adapted from Prof. Dr. Dentel Notes and Prof. Dr. Chang-Yu Wu

  2. Fabric Filters • Well known and accepted method for separating dry particles from a gas stream • Many different types of fabrics, different ways of configuring bags in a baghouse and different ways of flowing the air through the bags. • There are 3 common types of baghouse based on cleaning method • Reverse-air • Shaker • Pulse-jet

  3. Fabric Filters

  4. Fabric FiltersA shaker baghouse Filter compartements

  5. Fabric Filters

  6. Fabric Filters

  7. Filtration Theory

  8. Filtration Theory

  9. Filtration Theory Figure 6.2 pp 186

  10. Filtration Theory

  11. Filtration Theory

  12. Design Considerations

  13. Cleaning Cycles • tf: time interval between two cleanings of the same compartment • tr: time interval between cleanings of any two compartment

  14. Variation of pressure drop with time DPm DP tr tc Time

  15. Cleaning Cycles

  16. Table 6.4 Ratio of actual filtering velocity uj to average filtering velocity uN-1 in a multicompartament baghouse

  17. Maximum Filtering Velocities in Shaker or Reverse Air Baghouses • Table 6.1

  18. Fabric Selection Table 6.2

  19. Pulse Jet Filters • Introduced 45 years ago captured one-half of the industrial air filtration market • Air is filtered through the bags from outside to the inside, a cage inside each bag prevents the bag from collapsing • The bags are cleaned by short blast of high pressure air (90-100 psi) • Each bag is pulsed every few minutes • On stream use

  20. Pulse Jet Filters • There are no compartments and thus no extra bags which reduces size and cost (for a large coal-fired power plant, the baghouse is so large that it is designed with separate compartments) • Since bags are placed from the top, no need to provide walkways between rows of bags (reducing the size) • Felted fabrics can be used at much higher air to cloth ratio (higher filtering velocities)

  21. Pulse Jet Filters • Table 6.5. Maximum Filtering Velocities for Various Dust or Fumes

  22. Advantages • -High collection efficiency on both coarse and fine PM • -Insensitive to fluctuations in gas stream • -Filtered outlet air is very clean and may be recirculated within the plant • -Collected particles are dry for subsuquent processing or disposal • -Operation is relatively simple • -Unlike ESP, do not require the use of high voltages, maintenance is simplified • -The use of selected fibrous or granular filter aids (precoating) permits the high efficiency collection of PM1 smokes and gaseous contaminants • -Can be modular

  23. Disadvantages • Over 290 C expensive special refractory mineral or metallic fabrics are required • Concentrations of some dusts in the collector, may represent a fire of explosion if a spark or flame is accidentally admitted. • Fabrics can burn if readily oxidizable dust is being collected • Fabric filters have relatively highmaintenance requirements (periodic bag replacement)

  24. Disadvantages • Fabric life may be shortened at elevated temperatures and in the presence of acid or alkaline PM or gas constituents • Cant be operated in the presence of hygroscopic materials, condensation of moisture or tarry adhesive components may cause plugging of the farbri or reqire sepcial additives • Pesprotory protection for maintenance personel may be required when replacing fabric • Medium pressure drop is required (4 to 10 inches of water column)

  25. Example

  26. Example

  27. Example

  28. Other Considerations • Temperature and Humidity : Fabrics have different maximum allowable teperatures. Low T can cause condensation of acid and/or blinding of the fabric with wet dust • Chemical nature of gas: Different fabrics have different resistance to acids or alkalies • Fire/explosion: Some fabric are flammable; Some dust are explosive • Dust Handling: dust removal rate, conveyor system, and hopper slope should all be considered

  29. Educational Videos • http://www.youtube.com/watch?v=bbXZCzgZh4wAnimationshowingthepulse jet filtration • http://www.youtube.com/watch?v=9BXEcb5RXG4 A presentationfromBaghouseandWetScrubberProduction Firm, MikroPul

  30. Wet Scrubbers

  31. Particulate Scrubbers Types of scrubbers: spray chamber and venturi scrubber Theory and design consideration Pressure drop Contacting power Reading: Chap. 7 2020/1/2 Aerosol & Particulate Research Lab 32

  32. Spray Chamber Collecting medium: • Liquid drops • Wetted surface Recirculated water Water to settling basin and recycle pump Vertical spray chamber (countercurrent flow) 2020/1/2 Aerosol & Particulate Research Lab 33

  33. 2020/1/2 Aerosol & Particulate Research Lab 34

  34. Cyclone Spray Chamber & Impingement Scrubber Flagan & Seinfeld, Fundamental of Air Pollution Engineering, 1988 2020/1/2 Aerosol & Particulate Research Lab 35

  35. Venturi Scrubber High efficiency even for small particles VG: 60 - 120 m/s QL/QG: 0.001 - 0.003 Handbook of Air Pollution Control Engineering & Technology, Mycock, McKenna & Theodore, CRC Inc., 1995. 2020/1/2 Aerosol & Particulate Research Lab 36

  36. Theory: Spray Chamber Volume of each droplet Total number of droplets that pass the chamber per second VG QL: volumetric liquid flow rate Droplet concentration in the chamber Vd Vtd Vd: droplet falling velocity relative to a fixed coordinate Vtd: droplet terminal settling velocity in still air (i.e. relative to the gas flow) 2020/1/2 Aerosol & Particulate Research Lab 37

  37. At a given time dt, the distance a droplet falls is Volume of air that flows through the cross-section area of a single droplet during the time dt Total effective volume of gas swept clean per second by all droplets in dz Total number of particles swept clean per second by all droplets in dz 2020/1/2 Aerosol & Particulate Research Lab 38

  38. Total number of particles removed per second over dz QL Penetration can be defined as the fraction of particles of a specified diameter (Pd) that are not capture. hd=1-Pd Particle penetration in a countercurrent vertical spray chamber: Cross-sectional area of all the droplets QG Overall penetration then will be sum of Pd 2020/1/2 Aerosol & Particulate Research Lab 39

  39. If QL in gal/min and QG in cfm, z in ft and dd in mm Particle penetration in a cross-flow spray chamber Q: How do we have higher collection efficiency? Q: What are the collection mechanisms (we need it for hd)? 2020/1/2 Aerosol & Particulate Research Lab 40

  40. 2020/1/2 Aerosol & Particulate Research Lab 41

  41. Deposition of Particles on a Spherical Collector Particle Reynolds # Particle Stokes # Particle Schmidt # Diameter ratio Viscosity ratio Single droplet collection efficiency d (diffusion) (interception) (impaction) 2020/1/2 Aerosol & Particulate Research Lab 42

  42. (Impaction parameter Kp is used in textbook; Kp= 2 St) Impaction only rp = 2 g/cm3

  43. Venturi Scrubber • Use intertial impaction of suspended particles on water droplet formed by gas atomization

  44. Venturi Scrubbers: Calvert Design Particle penetration through a venturi scrubber Kpo=2St (aerodynamic diameter) using throat velocity f = 0.5 for hydrophilic materials, 0.25 for hydrophobic materials Atomization produces a wide distribution of droplet size. However using the Sauter mean droplet diameter (dd) equation can be solved with satisfactory results. sin dyne/cm, rL in g/cm3 and m should be in poise QL and QG should be of the same unit k1 = 58600 if VG is in cm/s = 1920 if VG is in ft/s 2020/1/2 45

  45. Pressure Drop Venturi Scrubber lt: venturi throat length X: dimensionless throat length Ex: 10” water, 2 mm, h = ? 2020/1/2 Aerosol & Particulate Research Lab 46

  46. Contacting Power Approach When compared at the same power consumption, all scrubbers give the same degree of collection of a given dispersed dust, regardless of the mechanisms involved and regardless of whether the pressure drop is obtained by high gas flow rate or high water flow rate Nt: Number of transfer unit (unitless) (PT:contacting powerin hp / 1000 cfm) a and b: coefficient and exponent of PT PT should be determined from the friciton loss across the wetted portion of the scrubber. 47

  47. Contacting Power Approach Venturi scrubber collecting a metallurgical fume Contacting power, hp/cfm

  48. Example Q: Tests of a venturi scrubber show the results listed on the right. Estimate the contacting power required to attain 97% efficiency. (PTcontacting powerin hp / 1000 acfm) Nt: Number of transfer unit (unitless) (1 inch of water = 0.1575 hp/1000 cfm)

  49. Example Convert friction loss to contacting power (hp/1000 cfm): 1 in H20 =0.1575 hp/1000cfm