IR/VIS/UV/X/gamma/ TeV detectors and readout electronics 10 -2 ÷ 10 12 eV

IR/VIS/UV/X/gamma/ TeV detectors and readout electronics 10 -2 ÷ 10 12 eV. Claudio Labanti , Giovanni Bonanno, Favio Bortoletto , Ezio Caroli, Rosario Cosentino, Ettore Del Monte, Marco Feroci, Giovanni La Rosa, Claudio Macculi , Michela Uslenghi. Napoli 27-28.3.2019.

dthelma
Télécharger la présentation

IR/VIS/UV/X/gamma/ TeV detectors and readout electronics 10 -2 ÷ 10 12 eV

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IR/VIS/UV/X/gamma/TeV detectors and readoutelectronics 10-2 ÷ 1012eV Claudio Labanti, Giovanni Bonanno, FavioBortoletto,Ezio Caroli, Rosario Cosentino, Ettore Del Monte, Marco Feroci, Giovanni La Rosa, Claudio Macculi, Michela Uslenghi Napoli 27-28.3.2019

  2. Detector scenario vs E range Legenda: CCD Charge Coupled Devices CZT CdZnTe detector GPD Gas Pixel Detectors NTD-Ge Neutron Transmutatio Doped µcal SPAD Single Photon Avalance Photodiode TES Transition Edge Sensor µcal SDD Silicon Drft detectors SiPM Silicon PhotoMultiplier

  3. Detector task Immaging: With resolution spanning from few µm (CCD) to mm Spettroscopy: With high resolution as some eV (TES) and wide ranges (SDD,CZT) Timing: With resolutions down to some tenth of psec (SPAD, SiPM) Polarimetry: directly or in dedicated arrangement In ground based or space applications

  4. IR pixelated detectors • Characteristics • arrays up to 4k x 4k pixels • HgCdTe (0.8–10 μm) • SiAs (3–28 μm) • InGaAs (lower cost technology) • INAF • The involvement of the astronomical community is and will be based on laboratory performance evaluation, optimization and adapting to different applications • HgCdTe are at the base of the focal planes for • JWST, Euclid and WFIRST for space • ESO VISTA ground telescope. • SiAs are foreseen for next generation VLTI instruments and for METIS, on ELT. Industry The national industry (Leonardo, DRS) on these technologies lags behind US off the shelf products.

  5. Silicon Carbide Photo Multiplier (SiCPM) for UV solar blind application Characteristics 4H-SiC based photodiodes are suitable choice for UV astronomy owing to their high intrinsic visible blindness INAF SiC-APD technology developed at CNR-IMM, in collaboration with INAF and ST Microelectronics succeeded in obtaining. The next step will be the realization of a SiC-SPAD (technology that allows to operate a SiC-APD in Geiger mode) using quenching resistors and finally assembling many SiC-SPAD in parallel to obtain SiCPMs. Industry Collaboration with ST Microelectronics.

  6. Optical detectors Characteristics State of the art CCD offers the possibility of large mosaics of CCD in the extended range of high QE (400-800 nm) and low dark noise (4e-/pix/hour) CMOS are optimal for short-time exposure applications (fast imaging, adaptive optics, space applications). INAF CCD or CMOS detectors are used in all the ground telescopes and several space missions. While the detectors are made by the industry, the development of the front-end electronics, the detector controller, the test and the characterization are carried out in the INAF institutes.

  7. SiliconPhotomultiplier (SiPM) Characteristics Alternative to PMTs in almost all astronomy applications SDD operate in a limited Geiger mode, in order to achieve a gain at the level of 106 high QE, fast response. INAF The SiPMare studied in INAF, as focal plane sensors of the Imaging Atmospheric Cherenkov Telescope (IACT) and for ASTRI SST-2M a Cherenkov telescope prototype proposed by INAF as Small Sized Telescope (SST) for the Cherenkov Telescope Array (CTA) observatory. • Industry • Two Italian industries offer state-of-the-art SiPM: • AdvanSiD • ST Microelectronics

  8. piano focale con 21 moduli senzafiltro telescopio ASTRI prototipopressol’osservatorio INAF di Serra La Nave (CT) SiPM + elettronica di Front End nellospazioridotto di un modulo (56x56mm) Courtesy G. La Rosa

  9. Large area Silicon Drift Detectors (SDD) • Characteristics • Very low noise devices that can operate both as • direct X-ray detectors • photodiodes for the read-out of scintillating crystals in gamma ray instruments • can be designed in different sizes and geometries, in single pixel, large area or arrays of different size pixels. INAF A collaboration with INAF, INFN, ASI, Universities (PoliMi, Uni-Pv and UniBo) and FBK (Fondazione Bruno Kessler, Trento)brought SDDs into space astronomy as enabling technology for large-area spectral-timing experiments as LOFT ESA-M3 and M4 eXTPwith China, STROBE-X with NASA, THESEUS and eASTROGAM with ESA and HERMES with ASI Industry FBK is one of the few producer in the world of state of the art SDD Italian industries are involved in all the space mission that use this technology

  10. Current developments • Multi-cell SDD • Custom size and shapes • Thin entrance window for low energy (<< 2 keV) and scintillation light read-out • Wide band High Energy Astrophysics • Enabling technology for THESEUS/XGISand HERMES • Large Area Linear SDD • 76 cm2 active area (largest SDD ever built) • Aimed at high-throughput X-ray Astrophysics on collimated instruments • Enabling technology for LAD and WFM instrument on-board eXTP • Pixelated SDD (PixDD) • 300 μm pitch, 16x8 →32x32 pixels • Aimed at high-throughput X-ray Astrophysics on focal planes • High spectral resolution (<150 eV FWHM @ 5.9 keV) with low power consumption and no cooling Courtesy M. Feroci, Y. Evangelista

  11. Single Photon Avalanche Diode (SPAD) Characteristics SPAD feature single photon detection efficiency, a timing accuracy as good as 40 ps, although with no spectroscopic capabilities Detector range from 50 μm and up to 500 μm diameter INAF SPAD are developed at Politecnico di Milano and manufactured at IMM-CNR. Their application in astronomy both naked than coupled to scintillating-fibers are studied within INAF and ASI funded technological projects Industry Micro Photon Device a PMI from Bz develops and produce photon counting devices based SPAD.

  12. SPAD da 500 mm

  13. 3D CZT/CdTespectro-imager detectors • Characteristics • Semiconductor devices (CdTe and CZT) for 3D spectro-imaging in the  range • good spectroscopic resolution • submillimeter position resolution INAF INAF research groups proposed these detectors for scattering polarimetry at the focal plane of broadband Laue lens telescopes (ASTENA) and/or high-energy concentrators (HAED). Their sensitivity will allow high-energy polarimetry to become a standard method of observation for X and gamma-ray sources, in addition to spectroscopy, imaging and timing. At present INAF works closely with IMEM/CNR, DIFC (Palermo University), Pavia University and INFN. INAF groups contribute design configuration and optimization Industry Due2Lab develops and produce CdTe, CZT sensors and system XGLab produces Low Noise Preamps, ASIC, Digitizer CAEN Custom designed digitizer

  14. 3D Sensor Unit: (a) drift strip configuration for anodes, (b) segmentedorthogonalcathode. Readout of collecting anodes, grouped drift strips and cathode signals: Few readout channels (25) to obtain a segmentation equivalent to: 80000 voxels The Digital Pulse Processing readout approach: In a space instrument, the detector performance can be tuned to the observational targets and mission contest, without requiring HW change. 3D CZT/CdTe spectro-imager detectors & polarimeters Performance: a 3D sensor unit (20x20x5 mm3) can achieve fine energy resolution and 3D imaging capability. 3D spatial resolution at 400 keV: x = 0.15 mm, y = 0.26 mm, z = 0.65 mm Scattering Polarimetry performance. The modulation curve (blue) measured with a thin (1 mm) and fine (0.625 mm pitch) pixel CZT sensor: Q=~0.78, very close to the expected values of 0.9 (red line). The performance are equivalent to ones achievable with a 3D CZT spectro-imager, selecting events which scatter at large angles (close to 90 degrees). Energy resolution: from2% at 59.9 keV to 0.6 % at 661.6 keVusing signals compensation technique allowed by the photon interaction 3D position knowledge.. Courtesy E.Caroli

  15. Gas Pixel Detector (GPD) and Compton Polarimetry • Characteristics • GPD is a gas proportional counter for X-rays tracking the path of photoelectrons emitted in photon absorption • Measure the polarisation of X ray up to ∼10 keV (that can raise up to 35 keV) • Is an imager with with a spatial resolution of ∼30 μm INAF GPD was invented by an INAF INFN collaboration can be used e.g. as focal plane detector for Lobster Eye Optics. GPD was proposed for the missions XIPE (ESA) and eXTP(Sino-Eu) and is now the focal plane instrument selected NASA mission IXPE. At INAF study are undergoing for measure polarization above 30 keVexploiting the anisotropy of the Compton Effect. The detector is composed of a low-Z scattering element and a high-Z absorber). Industry Italian industries are involved in the manufacturing of the GPD and in all the space mission that use this technology.

  16. Compton polarimeterabove 30 keV The Compton polarimeter is based on plastic scintillator scattering stages and inorganic scintillator absorbing stages. Both stages are read-out using SiPMs. Two geometries: focal plane (left figure) and large area (right figure) Low Z scintillator (scatterer) High Z scintillators (absorbers) Low Z scintillators (scatterers) High Z scintillators (absorbers) Costa et al., NIM A, 366, 161 (1995) Fabiani et al., Astrop. Physics, 44, 91 (2013)

  17. Neutron Transmutation Doped NTD Germanium X-Ray microcalorimeters Characteristics Excellent energy resolution Single, cryogenic semiconductor micro-machined micro-calorimeters with NTD Ge thermistors have widely and successfully been adopted from infrared to soft-gamma rays. Usable in a wide range of temperature, with a wide dynamic energy range with a read-out electronics based on low noise, low cost, commercially available components. INAF INAF is developing a planar process to build scalable arrays, optimize the performance for X-ray detection, and increase the count rate.

  18. Transition Edge Sensor TES Microcalorimeter detectors and Cryogenics Characteristics Excellent energy resolution . The technology deal with microcalorimeter made of normal-metal, semiconductors and superconductors cooled at 0.1K, and the readout electronics (cold based on SQuID, and warm electronics) INAF The main scientific driver is related to the ATHENA ESA mission. In the frame of an INAF- INFN collaboration and inside an international consortium that will build the TES-based X-IFU instrument on board ATHENA. INAF has the responsibility of Cryogenic Anti-Coincidence detector (CryoAC) of X-IFU • Industry • The CryoAC will be fully developed in Italy. The spin-off towards the Italian industries is robust and concern • TAS-I (electronics) • CGS/FBK (electronics and structural issues)

  19. The present: CryoAC Demonstration Model Suspended aborber Courtesy C. Macculi

  20. Read-out electronics Scenario Special instruments require special electronics developed inside INAF laboratories. This is particularly true for electronics that involve Application Specific Integrated Circuits (ASIC) or programmable logic, like Field Programmable Gate Array (FPGA). INAF INAF scientists drive the design and development of ASICs and FPGA firmware in order to satisfy the scientific requirements also in collaboration with Universities and INFN. Industry The industry enters mainly at the engineering phase, for satellites or ground telescopes. The development of specific electronics thus requires that the expertise is maintained in the INAF laboratories, working in synergy with industries.

  21. VLSI electronics VEGA ASIC 32 ch in line for SDD read-out designed for LOFT Design Poli-Mi, Uni-PV 20 e-rms noise, 0.5 mW/ch, 200 µm pitch From VEGA came out the design for HERMES and THESEUS_XGIS ASICs RIGEL ASIC 16x8 ch array for Pixdd SDD read-out Design Poli-Mi, Uni-PV 300x300 µm pitch The detector is ‘ball-bonded’ above the ASIC