1 / 19

Si Pixel Tracking Detectors

Si Pixel Tracking Detectors. Introduction Sensor Readout Chip Mechanical Issues Performance -Diamond. 36 MPix 150x150mm 2. HISTORICAL. Vertex High Radiation Stand- resolution multi hardness alone Tracking Trig

gema
Télécharger la présentation

Si Pixel Tracking Detectors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Si Pixel Tracking Detectors • Introduction • Sensor • Readout Chip • Mechanical Issues • Performance • -Diamond

  2. 36 MPix 150x150mm 2

  3. HISTORICAL Vertex High Radiation Stand- resolution multi hardness alone Tracking Trig 80’s- CCD detectors- SLD X Si - diode x x 90’s- Si - diode- Omega2/3,DELPHI X X x Si - diode- SSC/LHC X X X Diamond x x x 2000’s Si - diode/ LHC/BTEV X X X X Diamond X X X X

  4. Track Cluster • Pixel Tracker • Pixel Size • Occupancy • Charge Sharing • S/N • ExB Drift • Radiation Damage • LHC - 1014 /cm2/yr & Trigger Single Track Charge Sharing Vertex Resolution (20-30)mm IP

  5. Radiation Damage Effects • Increase in volume leakage current. • Build-up of effective p-doping (bulk inversion). • Charge trapping. • Reverse Annealing- inactive defects become active, • increasing effective p-doping. (T-dependent)

  6. Basic Diode Structure • .

  7. BASIC PACKAGE • Sensor Bump Bonded to Readout Chip • In or Pb/Sn for Bumps • Wafer Thinning • Dicing • Yield

  8. Single Ring p-stop Design n+ n- p+ • Sensors & Isolation • Guard Ring Design • p-stop, p-spray • Radiation Damage • -Bulk Damage • -Depletion Voltage • Type Inversion • Self Annealing/Thermal • Diamond Detectors • -Radiation Hard • -Simple Architecture Electrode Diamond Electrode CVD DIAMOND

  9. READOUT CHIP (CMOS) • Radiation Hard Architecture (SOI) • Military/ Space Science • Analoque/Digital • SEU, Latchup (10-6 -10-10) • DMILL .80mm Bi-CMOS • IBM .25mm <----- Thin Si Layer Oxide Si Substrate PSI Readout Chip

  10. Reflow and Wick-over • BUMP and FLIP-CHIP Interconnect • Choice of Indium or Solder (PbSn) • Indium • -Evaporation, 2 bumps, Allignment • -High Yield • Electroplated Solder • -Reflow techniques • ~180oC. Flux, Self Alligning • -Complex UBM (UnderBump Metalization) • -Excellent Electrical and Mechanical • Contact Readout Chip Sensor

  11. 8.0mm Detectors TBM 52 x 53 array 150 x 150mm Clk 10.5mm Optical links FEC FED DOUBLE COLUMN PERIPHERY Fast Trigger TIME STAMP and READOUT BUS T TRIGGER BLK Readout Amplifier Transmission Line Drivers I2C DACS CONTROL and INTERFACE BLOCK Power Supply / Clock Pads 400K transistors ~30%yield Pseudo -TRIGGER PAD SLOW CONTROL UPLOADS 40MHz I2C DATA FAST TRIGGER OUT (L3)

  12. Low Mass Support Structures - Be , C-Fiber Wafer Thinning -.25 mm lithography on 8”800mm Dicing Accuracy and Placement Radiation Hard Glues/Epoxies Cooling (KWs per Detector) - (10-20) oC Flurocarbons (high mass) Evaporative Cooling(low mass) Thermal Expansion MECHANICAL COOLING

  13. High Density Interconnects VHDI Sensor ROC Bump Bonds HDI Wire Bonds Be Panel Silicon Plate

  14. PERFORMANCE (Si & Diamond in CERN Test Beam) Charge Sharing Vienna Repeater Y Row X Z, B } Double Column Beam 20o ROC, PSI36: 11 double columns x 30 rows Pixels 150 x150 m2 8mm D:\Transfer from Bob\Pictures\Test Beam Hardware\Geometry Pixels.ppt

  15. Si 25000e/mip 2000e noise 99% efficiency Dia 9000e/mip 2000e noise 95% efficiency PERFORMANCE (cont) Charge sharing vs position Pixels at 20o to beam  = 14 m over pixel 150 m 150 m Charge sharing vs position 150 m / 12 = 43 m  = 46 m over pixel Pixels normal to beam

  16. CONCLUSIONS • Si Pixel Detectors- a Great Challenge! • Many Difficult Technologies to Master. • Much Will be Solved in LHC/BTeV era. • HEP Must Learn to Deal with High Development Costs. • Trigger Possibilities Abundant. • Diamond Detectors Feasible.

  17. X-Ray Crystalography

More Related