html5-img
1 / 1

The GLAST LAT Silicon Strip Tracker-Converter

Calibration mask and capacitors. Structural Closeout Wall. Gr/CE Face Sheet. Control logic. Trigger and Data mask registers. Control logic. 4-deep event memory. 64 amplifier-discriminator channels. 2 DACs. I/O pads and protection structures. Memory. Thermal Boss.

ghalib
Télécharger la présentation

The GLAST LAT Silicon Strip Tracker-Converter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Calibration mask and capacitors Structural Closeout Wall Gr/CE Face Sheet Control logic Trigger and Data mask registers Control logic 4-deep event memory 64 amplifier-discriminator channels. 2 DACs I/O pads and protection structures Memory Thermal Boss Aluminum Honeycomb Core MCM Closeout Wall (AAS 207th Meeting Abstract ID #667) The GLAST LAT Silicon Strip Tracker-Converter Robert P. Johnson, U.C. Santa Cruz and the Santa Cruz Institute for Particle Physics, on behalf of the GLAST/LAT team. Institutions in the GLAST/LAT Tracker-Converter team: Hiroshima University, INFN Bari, INFN Padova, INFN Perugia/Terni, INFN Pisa, INFN Roma-II, Santa Cruz Institute for Particle Physics, Stanford Linear Accelerator Center Summary The GLAST instrument concept is a gamma-ray pair conversion telescope that uses silicon microstrip detector technology to track the electron-positron pairs resulting from gamma-ray conversions in thin tungsten foils. A cesium iodide calorimeter following the Tracker is used to measure the gamma-ray energy, and the Tracker is surrounded on the other 5 sides by plastic scintillating detectors (ACD) for rejection of charge-particle backgrounds. Silicon strip technology is mature and robust, with an excellent heritage in space science and particle physics. It has many characteristics important for optimal performance of a pair conversion telescope, including high efficiency in thin detector planes, low noise, and excellent resolution and two-track separation. The flight-instrument design includes a 44 array of Tracker modules, with a total of 884,736 detection channels and 9216 silicon-strip detectors. This amounts to a total of 73.8 square meters of silicon! The large size of GLAST and the high channel count in the Tracker puts demands on the technology to operate at very low power, yet with sufficiently low noise occupancy to allow self triggering. The large cosmic-ray rate through the GLAST aperture demands that the Tracker be capable of reading out at rates as high as 10 kHz with negligible dead time. The mechanical design must be robust, to survive the flight vibration, vacuum, and thermal environments, and yet it must also be light weight and highly transparent to charged particles. Pair Conversion Telescopes The LAT Instrument ACD Tracker Conversion point, followed by multiple scattering Multiple scattering here does not hurt much, as long as a point is measured immediately following. Calorimeter Simulation of a GLAST event in a 44 array of tower modules. A 100 MeV gamma ray (white line) enters the right-most tower at 90 degrees and converts in the first lead foil. The blue lines show the reconstructed trajectories of the electron and positron. White lines show the trajectories of low-energy x-rays produced in the electromagnetic shower. The LAT Science Instrument consists of 3 detector systems: the Tracker, Calorimeter, and ACD. The Tracker and Calorimeter are each made up of 16 separate modules, while the ACD covers the Tracker with plastic scintillator tiles, each read out by 2 photomultiplier tubes. The detectors are supported by an aluminum Grid that incorporates heat pipes to carry the Tracker and Calorimeter electronics waste heat to the perimeter of the instrument. Shown here are the 16 Tracker modules mounted on the Grid, prior to installation of the ACD. The 16 Calorimeter modules are installed in the Grid but are not visible. The Tracker modules are separated by 2.5 mm gaps. For all but the highest energy photons, the angular resolution is limited by multiple scattering in the heavy-metal converter foils. In that case, most of the direction measurement power comes from the first two tracker planes following the conversion. As long as a point is measured by detectors immediately following the second converter foil, then the measurement is only degraded by the foil in which the conversion occurred. If one of the first two points is missed, then the resolution is typically degraded by a factor of two. Therefore, high detector efficiency is crucial. Silicon Strip Detectors Application Specific ICs Mechanical/Thermal Design Readout Electronics (MCM) Bias Resistor Composite Panel Machined corner radius with bonded flex circuit. Flex Circuit Interconnect Readout ICs Detector Inverted Tower with Sidewall Removed Composite Sidewall Composite Panel Readout IC Readout Controller IC Readout Electronics Adhesive bond 37-pin nano-connector with connector saver 8-layer PWB Amplifier-Discriminator Chip Readout Controller Chip The right-hand quarter of an MCM (multi-chip readout module). The high density of readout channels needed by GLAST is readily provided by standard 0.5-m CMOS VLSI technology. Two different ASIC chips have been custom designed and manufactured for the Tracker. The first is a mixed analog-digital chip that includes 64 amplifiers and discriminators, digital circuitry for control, calibration, data buffering and readout, DACs for calibration and threshold settings, and differential drivers and receivers for communication. The second is a digital “readout controller” chip that acts as an interface between 24 amplifier chips and the data acquisition system. Each MCM includes 2 redundant readout controller chips, and the amplifier chips are able to send their data to either and be controlled by either. This gives a left-right redundancy for readout and control of each front-end electronics module. Titanium Flexures 6-inch wafer before cutting out the SSD Edge bond and wire bonds between 2 SSDs The signals from silicon-strip detectors must be amplified by electronics located as close as possible to the strips. Each electronics module, made on an 8-layer printed wiring board (PWB), serves 4 SSD ladders with a total of 1536 amplifiers distributed among 24 readout ICs. To minimize the dead space between Tracker towers, the electronics are mounted on the edges of the composite panels. A Kapton flex circuit is bonded over a machined 1-mm radius to carry the signals and bias potentials around the 90º corner to interface with the SSD ladders on the panel face. Two nano-connectors each interface a readout controller IC with the two redundant data acquisition cables. The 26 ICs are bonded directly to the PWB and interconnected by epoxy-encapsulated wire bonds. More than 11,000 8.95-cm square silicon-strip detectors were manufactured for GLAST by Hamamatsu Photonics. They are 400 um thick PIN diode structures made on 6-inch high-resistivity n-intrinsic silicon wafers. 384 strips of 228 m pitch are patterned on the junction side with AC coupling capacitors built in. Polysilicon resistors are used to bias the p-type diode strip implants. The detectors are fully depleted at a bias of about 100 V. Four detectors are edge bonded in series, with the strips connected by aluminum wedge wire bonds, to make a “ladder,” each with 384 strips of an effective length of about 35 cm. Flex-Circuit Cables The Tracker module structure is composed of 19 composite panels (“trays”) supported by carbon-composite sidewalls. Eight titanium flexures provide the mechanical connection between the bottom tray and the aluminum instrument Grid. Each of the upper 12 panels has thin tungsten converter foils (3% rad. len.) on the lower face. Each of the following 4 panels has thick tungsten foils (18% rad. len.) on the lower face. There are a total of 36 SSD layers, alternating in x,y orientation, each with an electronic readout module (MCM). The 9 MCMs on a side communicate with the data acquisition via two redundant flex-circuit cables. Composite Panel Assemblies Tracker Performance Tray Assembly Mechanical/Thermal Interface SSD’s Bias-Circuit Tracker Module on Test Stand Structural Tray Panel Thermal Straps Cable Termination & Support Nest for Alignment Targets Flexures The First Completed Flight Tray Converter Foils The GLAST tracker is cooled by passive conduction of heat from the electronics into the carbon-carbon closeout and then through the thermal boss into the tower sidewall. The heat then flows down the tower walls and into the grid support structure via copper thermal straps. The sidewalls are faced on both sides by thin aluminum layers for shielding against radiative interference. The flexure mount between Tracker and Grid isolates the Tracker from thermal movement of the Grid. The bolts that fasten the flexures to the Grid pass through nested pairs of eccentric cones. By rotating the cones before installation, the alignment can be corrected to ensure that the Tracker sits precisely vertical. This is critical given the small 2.5 mm gap between towers. MCM Cosmic Ray Passing Through 2 LAT Towers, Tracker and Calorimeter Bias-Circuit SSD’s The Tracker detectors, converter foils, and readout electronics are supported by 19 stiff composite panels. The primary structure is an aluminum honeycomb faced with carbon composite sheets. The four closeouts are machined from a 3-D carbon-carbon material, which has good machining properties and thermal conductivity. The lowest panel is an exception—it has closeouts composed of a stronger M55-J carbon-fiber composite faced with a machined veneer of carbon-carbon. Four of the 19 panels support heavier tungsten foils than the others (0.72 mm vs. 0.10 mm) and therefore have heavier cores and stronger face sheets (6 ply vs. 4 ply). The stiff carbon composite panels protect the SSDs during the Delta-II launch and maintain accurate alignment. Each tray has SSDs on the top and bottom and electronics along two opposing sides (except that the top and bottom trays have SSDs on one side only). Alternating trays are rotated by 90 degrees with respect to each other. Each gap between trays thus has an x-y pair of detectors facing each other and separated by about 2 mm. Kapton bias circuits lie between the SSDs and panel and carry the bias voltage from the MCMs to the SSDs. The Tracker modules have been extensively tested with cosmic rays and with a strong x-ray source (to produce a rapid trigger rate). They have also successfully completed vibration testing, thermal-vacuum testing, and EMI/EMC testing. They meet all design requirements, including power consumption of 10 W per tower (180 W per channel), layer hit efficiencies >98% (typically >99.5%) within the active area, and low noise occupancy, below 106 per channel per trigger. They self trigger reliably, and they can be read out at rates exceeding 10 kHz with negligible dead time.

More Related