1 / 16

FNAL TB09 Plots

FNAL TB09 Plots. Alessandra Borgia Syracuse Unviersity Marina Artuso , Jianchun Wang, Ray Mountain January 20, 2010. Plots that are Ready as of Today. All are complete for both sensors, n- and p-type. Ped and CMS Noise – There are many! Signal vs channel

gomer
Télécharger la présentation

FNAL TB09 Plots

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FNAL TB09 Plots Alessandra Borgia Syracuse Unviersity Marina Artuso, Jianchun Wang, Ray Mountain January 20, 2010

  2. Plots that are Readyas of Today • All are complete for both sensors, n- and p-type. • Ped and CMS Noise – There are many! • Signal vs channel • Gaussian fits per each sector • Test Pulse • MPV vs link • MPV vs Y Position (mm) for 500 V • Cluster sizes for HV Scan when P type is High Irr • Efficiencies for HV Scan when P type is High Irr Alessandra Borgia, Syracuse University Velo Meeting

  3. Plots Not Ready yet • MPV vs Y Position (mm) for other voltages • ADC vs Voltage projection, slice of MPV vs Y Position at high irr. • Cluster sizes for HV Scan when N type is High Irr • Efficiencies for HV Scan when N type is High Irr • All are in process. Alessandra Borgia, Syracuse University Velo Meeting

  4. Noise Plots N Type – 500V– Pedestal ADCs Channel ADCs Signal + JC Effect Signal N Type – 500V– CMS Alessandra Borgia, Syracuse University Velo Meeting Channel

  5. Noise File Name: RR_0deg_Top_latency_0x17_delay_40ns_Kazu_HV500-20090427-081938.mdf Conditions: Beam at Top N type – Low Irr P type – High Irr N Type – 500V– Ped N Type – 500V– CMS What these plot represent: Plots of the means of Gaussian noise fits for each strip in a sector. i.e. sum of noise in a sector Alessandra Borgia, Syracuse University Velo Meeting

  6. Noise File Name: RR_0deg_Top_latency_0x17_delay_40ns_Kazu_HV500-20090427-081938.mdf Conditions: Beam at Top N type – Low Irr P type – High Irr P Type – 500V– Ped P Type – 500V– CMS Dead chip on p-type will be removed Alessandra Borgia, Syracuse University Velo Meeting

  7. Test PulseN Type: Channels 9 and 30due to timing shift 2 channels are pulsed per link, so 128 channels hit. **Means obtained the same way as the noise,only I pick out the channel that has the signal on it, which I know before hand; plot mean per link. Alessandra Borgia, Syracuse University Velo Meeting

  8. Test PulseP Type: Channels 3 and 24 Alessandra Borgia, Syracuse University Velo Meeting The ADC value should by consistent for each link.

  9. N Type Charge Collection Alessandra Borgia, Syracuse University Velo Meeting

  10. N Type withfluence superimposed Alessandra Borgia, Syracuse University Velo Meeting

  11. P Type Charge Collection Alessandra Borgia, Syracuse University Velo Meeting

  12. P Type withfluence superimposed Alessandra Borgia, Syracuse University Velo Meeting

  13. ADC vs Voltage projection **NB** Of course, will do it properly….wanted to see the shape. Just from eyeballing, this is the shape: JC’s ppt from last week’s SU Velomtg Alessandra Borgia, Syracuse University Velo Meeting

  14. Cluster Size where P type is High Irr at 500V File Name: RR_0deg_Top_latency_0x17_delay_40ns_Kazu_HV500-20090427-081938.mdf Conditions: Beam at Top N type – Low Irr P type – High Irr N Type 500V P Type 500V Alessandra Borgia, Syracuse University Velo Meeting

  15. Cluster Size where P type is High Irr50V File Name: RR_0deg_Top_latency_0x17_delay_40ns_Kazu_HV50-20090427-060008.mdf Conditions: Beam at Top N type – Low Irr P type – High Irr N Type 50V P Type 50V Alessandra Borgia, Syracuse University Velo Meeting

  16. Efficiencies Efficiencies considered when: 1 track from pixel telescope is within ± 100um of cluster position on sensor Alessandra Borgia, Syracuse University Velo Meeting

More Related