An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PERSONAL PROTECTIVE EQUIPMENT

  2. OBJECTIVE • Without reference, identify basic facts about personal protective clothing with an overall minimum of 70% accuracy.

  3. Full protective equipment for structural fighting:

  4. Helmet • Protects the head, face, and eyes from: • Impact injuries. • Puncture injuries. • Scalding water.

  5. Protective Hood • Protects portions of the firefighter’s face, ears, and neck not covered by the helmet or coat from exposure to extreme heat.

  6. Protective Coat and Trousers • Protects trunk and limbs from: • Cuts. • Abrasions. • Burn injuries (resulting from radiant heat). • Provide limited protection from corrosive liquids.

  7. Gloves • Protects the hands from: • Cuts. • Wounds. • Punctures. • Burn injuries.

  8. Safety Shoes or Boots • Protect the feet from: • Burn injuries. • Puncture injuries

  9. Eye Protection • Protects the wearer’s eyes from flying solid particles or liquids.

  10. Hearing Protection • Limits noise-induced damage to the firefighter's ears when loud noises cannot be avoided.

  11. Self-Contained Breathing Apparatus (SCBA) • Protects the face and lungs from toxic smoke and products of combustion.

  12. Personal Alert Safety System (PASS) • Provides life-safety protection by emitting a loud shriek if the firefighter should collapse or remains motionless for approximately 30 seconds.

  13. Personal Protective Equipment • NFPA 1971, Standard on Protective Ensemble for Structural Fire Fighting. • Includes coats, trousers, coveralls, helmets, gloves, footwear, and interface components (protective hoods and wristlets).

  14. NFPA 1971 • All components must have an appropriate product label permanently and conspicuously attached. • The label contains the following information:

  15. "THIS … MEETS THE … REQUIREMENTS OF NFPA 1971, STANDARD ON PROTECTIVE ENSEMBLE FOR STRUCTURAL FIRE FIGHTING, 1997 EDITION." • Manufacturer's name, identification, or designation. • Manufacturer's address. • Country of manufacture. • Manufacturer's identification number or lot number or serial number. • Month and year of manufacture (not coded). • Model name, number, or design. • Size or size range. • Garment materials (coats, trousers, coveralls, hoods). • Footwear size and width (boots). • Cleaning precautions.

  16. NFPA 1971 • All equipment should meet current applicable standards. • Firefighters must: • Understand the design and purpose of various types of protective clothing. • Be aware of each garments inherent limitations.

  17. Helmets • Older helmets • Traditional function was to shed water, not protect from heat, cold, or impact. • Wide brim was designed to prevent hot water and embers from reaching the ears and neck.

  18. Newer Helmets • Perform these functions as well as: • Protect the head from impact. • Provide protection from heat and cold. • Provide faceshields for secondary protection of face and eyes when SCBA is not required.

  19. Newer Helmets • Must have: • Ear covers - should always be used during fire fighting. • Chin straps - to ensure helmet stays in place upon impact. • Faceshields • Attach to the helmet. • Most flip up and out of the field of vision. • Most assemblies don't interfere with protective breathing equipment.

  20. Eye Protection • Eye injuries • One of the most common injuries on the fireground. • Not always reported. • Can be serious but are fairly easy to prevent.

  21. Eye Protection • Comes in many forms: • Safety glasses. • Safety goggles. • Helmet faceshields. • SCBA masks.

  22. Eye Protection • NFPA 1500 requires goggles or other appropriate primary eye protection to be worn when participating in operations involving flying particles or chemical splashes.

  23. Eye Protection • Situations where eye protection (other than helmet faceshields or SCBA masks) is needed include: • Fireground and station operations • Welding. • Grinding. • Cutting. • Vehicle extrications. • Brush fires. • Inspections in industrial occupancies.

  24. Eye Protection • Safety Glasses and Goggles • Protect against 85% of all eye hazards. • Several styles available. • Prescription safety eyeglasses should have frames and lenses that meet ANSI Standard Z87.1, Practices for Occupational and Educational Eye and Face Protection.

  25. Eye Protection • Warning signs should be posted near operations requiring eye protection.

  26. Use of Eye Protection • Must be: • Required by departmental SOPs. • Enforced by supervisors.

  27. Hearing Protection • Firefighters are exposed to variety of sounds: • In the station. • En route to the scene. • On the fireground. • Permanent hearing loss can result from exposure to these sounds or a combination of sounds.

  28. Hearing Protection Program • To prevent exposure to unacceptably high noise levels. • To identify, control, and reduce potentially harmful noise and/or provide protection from it. • Eliminating or reducing noise level is the best solution, but often not possible. • Acceptable hearing protection should be provided and used.

  29. Intercom / Ear Protection • Most common use of hearing protection for firefighters who ride apparatus that exceed maximum noise exposure levels. • Reduce the amount of noise and allow the crew to communicate or monitor the radio.

  30. Earplugs or Earmuffs • May be used for hearing protection. • If earplugs are used, each firefighter should be issued a personal set.

  31. Potential Hazards: • Earmuffs can compromise protection of the face by making it awkward to wear SCBA and protective hoods. • Earplugs may melt when exposed to intense heat. • For these reasons, it is impractical to wear hearing protection during structural fire fighting operations.

  32. Protective Hoods • Designed to protect a firefighter's ears, neck, and face from exposure to extreme heat. • Also cover areas not otherwise protected by the SCBA facepiece, ear covers, or coat collars. • Typically made of fire resistant materials. • Available in long or short styles. • Used with SCBA facepieces, they provide effective protection. • Must not interfere with facepiece-to-face seal.

  33. Firefighter Protective Coats • Used for protection in structural fire fighting and other fire department activities. • NFPA 1971 requires all protective coats to be made of three components: • Outer shell. • Moisture barrier. • Thermal barrier.

  34. Firefighter Protective Coats • Barriers • Trap insulating air that inhibits transfer of heat from outside to the firefighter's body. • Also protect firefighter from: • Direct flame contact. • Hot water and vapors. • Cold temperatures. • Other environmental hazards.

  35. Firefighter Protective Coats • All inner liners must be in place during any fire fighting operations. • Failure to do so may expose the firefighter to severe heat that could result in serious injury or death.

  36. Protective Coat Features • Collars must be turned up to protect the neck and throat. • Wristlets prevent water, embers, and debris from rolling down inside the sleeves. • Closure system on front of protective coats prevents water or fire products from entering through gaps between snaps or clips.

  37. Protective Coat Features • Protective coats which meet NFPA standards are designed to be cleaned according to manufacturer's specifications. • Reflective trim: • Should be maintained according to NFPA standards. • Should not be obscured by: • Pockets. • Patches. • Storm flaps.

  38. Firefighter Protective Trousers • An integral part of the protective ensemble. • Three-quarter boots and long coats • Do not provide adequate protection. • Are no longer permissible according to NFPA 1500.

  39. Selecting protective trousers • Consider same concepts of fabric selection, moisture barriers, and other considerations used in selecting protective coats. • Layering principles that apply to coats also apply to trousers. • Options, like reinforced knees and leather cuffs, may increase their durability. • Suspenders should be the heavy-duty type.

  40. Firefighter Protective Trousers • Protective trousers that meet NFPA standards are designed to be according to manufacturer's specifications. • Maintain reflective trim according to NFPA standards.

  41. Hand Protection • Most important characteristics: • Protection they provide against heat or cold. • Resistance to cuts, punctures, and liquid absorption. • Must allow enough dexterity and tactile feel for the firefighter to perform the job effectively. • Must fit properly and be designed to provide protection as well as to allow dexterity.

  42. Foot Protection • Numerous hazards to the feet at a fire scene: • Embers. • Falling objects. • Nails. • Foot protection should be selected to minimize risk of injury from these hazards.

  43. Foot Protection • Two Kinds of Foot Protection: • Protective boots for fire fighting and emergency activities. • Safety shoes: • Station wear. • Inspections. • Emergency medical responses. • Other similar activities.

  44. Foot Protection • Puncture Resistance • Should be provided by stainless steel midsole plate. • If there is doubt about midsole protection, X-ray the boot.

  45. Foot Protection • Insulation: • Required by some fire departments. • Disadvantage is that added weight adds to firefighter fatigue. • Select boot liner that will not break up and cause blisters and discomfort. • Some protective boots have shin pads to reduce strain from leg locks and crawling.

  46. Boot Size • Firefighters should be fitted as accurately as possible. • Half sizes available for men and women. • Firefighters should not share protective boots because this is an unsanitary practice. • When reissuing boots, sanitize them as recommended by an industrial hygienist.

  47. Safety Shoes or Boots • Should be worn while conducting inspections or doing work around the station. • Department may require them as part of daily uniform.

  48. Safety Shoes • Usually have: • Safety toes. • Puncture-resistant soles. • Special inserts. • Provide good support for climbing. • Give increased physical agility. • Are generally less fatiguing than protective boots.

  49. Leather Fire Fighting Boots • Can be used for: • Work at the station. • Conducting inspections. • Fire fighting operations.

  50. Wildland Personal Protective Clothing • Structural fire fighting protective clothing is generally too bulky, too hot, and too heavy for wildland fire fighting. • Wildland fire fighting personal protective clothing (brush gear) and equipment. • Specifications found in NFPA 1977, Standard on Protective Clothing and Equipment for Wildland Fire Fighting.