SlideServe
Menu
Préférences
© SlideServe · v2026

Update on Monte Carlo Background Studies for GERDA Collaboration - Dubna Meeting 2005

hisa avatar
10 diapositives · 261 Views · Sep 09, 2014

This presentation by Kevin Kröninger discusses the latest developments in Monte Carlo background studies for the GERDA experiment. Key topics include event simulation and energy loss modeling using MaGe, and the simulation of particle interactions within detector sensitive volumes. The presentation covers event generation with different decay generators, analysis procedures focusing on energy windows for 0νββ and 2νββ detection, and background suppression techniques. The findings indicate a background index of roughly 2·10^-3 counts/kg/keV/y, highlighting areas for future improvement.

Update on Monte Carlo Background Studies for GERDA Collaboration - Dubna Meeting 2005 - slide 1
01 / 10Update on Monte Carlo Background Studies for GERDA Collaboration - Dubna Meeting 2005
1 / 17

Télécharger la présentation

Update on Monte Carlo Background Studies for GERDA Collaboration - Dubna Meeting 2005
Une image / un lien ci-dessous est fourni (tel quel) pour télécharger la présentation

Politique de téléchargement : le contenu du site vous est fourni TEL QUEL pour votre information et votre usage personnel ; il ne peut être vendu, concédé sous licence ni partagé sur d’autres sites sans l’accord de son auteur.Le contenu vous est fourni TEL QUEL, pour votre information et votre usage personnel uniquement. Téléchargez la présentation en cliquant sur ce lien. Lors du téléchargement, si vous ne parvenez pas à télécharger une présentation, l’éditeur a peut-être supprimé le fichier de son serveur.Pendant le téléchargement, si vous ne parvenez pas à obtenir une présentation, le fichier a peut-être été supprimé par l’éditeur.

F I N

Plus de contenu associé

Transcription de la présentation
  1. Update on the Monte Carlo Background Studies Kevin Kröninger, MPI für Physik GERDA Collaboration Meeting, DUBNA, 06/27 – 06/29/2005

  2. Event Simulation • Use MaGe to simulate energy loss of particles traversing • detector • Save true MC information (for cross checks) and energy • deposited in sensitive volumes (hits) • Add hits in each volume and smear according to resolution • taken from Canberra ReGe detector and require at least • 10 keV (digis) Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  3. Event Generation • Used two different generators: • Decay0: Use for 0νββ and 2νββ as well as some • background sources (60Co, 214Bi, etc.) • Future → UseDecay5 (Qββ bug fix) • G4ParticleGun: Use for background sources in decay • chains or single isotopes like 68Ge • Future → Generate whole decay chain Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  4. Analysis • Energy has to be in vicinity of Qββ within 10 keV window • Require Anti-Coincidence, i.e. only one segment fires • (Phase II: 3 x 6 segments) • No use of pulseshapes yet • Suppression factor is fraction of observed and simulated • events (the lower the better) Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  5. Co-60 10 keV window around Qββ anticoincidence required Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  6. Pb-210 10 keV window around Qββ anticoincidence required top, bottom middle Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  7. 0νββ 10 keV window around Qββ Anti- coincidence required Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  8. Overview / Results Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  9. Conclusion • First background calculation for GERDA in Phase II setup • with MaGe is done • Background index is roughly 2·10-3 counts/kg/keV/y • → Factor of 2 off • Note GSTR-05-004 is avaiable at MPI-K website Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005

  10. Future Plans • Keep updating geometry (e.g. holder, new crystals, etc.) • Use decay chains and calculate reduction factor for each • isotope and part • Keep updating activities for materials – TG11? • Include pulseshape information Kevin Kröninger, MPI München GERDA Collaboration Meeting DUBNA, 06/27 – 06/29/2005