Requirements for XA Object Definition (ordered by Priority, highest on top)

Requirements for XA Object Definition (ordered by Priority, highest on top). Make distinction between ready-to-display and not ready-to-display images. Include Flat-Panel Detector Acquisition Information. Change precision of Attributes.

hong
Télécharger la présentation

Requirements for XA Object Definition (ordered by Priority, highest on top)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Requirements for XA Object Definition(ordered by Priority, highest on top) • Make distinction between ready-to-display and not ready-to-display images. • Include Flat-Panel Detector Acquisition Information. • Change precision of Attributes. • Include new Attributes to reduce number of private attributes. • Capability to store P-Values according to Part 14. • Include synchronization information like Waveform IOD. • Include DX defined X-Ray Tomography Module for XRF definition. • Scalable scope of Attributes on multi-frames, range of frames and individual frame - ”functional grouping like CT/MR Supplements 49/58”. • Include more Acquisition Context information (X-Ray generation, Dose). • Include Code Sequences for applicable attributes. • Analyze XRF definition for possible changes or inclusion of new definitions.

  2. XA SR Simple Reports/Results • Standard Procedures on Angio Images • Stenosis Report (diameters, areas, percentages) • Distance measurements (Location, reference, value) ? • Create simple Report templates • Simple (automated) Acquisition (Study) Report or Log by Modality • Acq. Info, and Dose information per run • Dilatation Timers, Comments • Technical Report • Only very limited contents, not a “Procedure Log” ==> If Part 16 and Supplements 66 and 76 already deliver solution for this, write a “white paper” to assure common understanding 2

  3. (XA) Single Patient Media Profile • Allow Combination of different • Compressions • Square/Non-Square Matrix Sizes • Non-Image Data • SOP-Classes • Multi-modality integration • Types of Media ==> Needs to be discussed with WG1 / WG5 3