1 / 1

NITRO-PHENYL-CARBAMIDE HPLC STATIONARY PHASES;

π-Select. π-Select. Eluent: 45% methanol. Eluent: water. Number of theoretical plates for BCD: 1800 plates/m. C: 4.7%. k’=0.54. Number of theoretical plates for BCD: 32000 plates/m. BCD. prescribed stop time. BCD. Conventional phenyl-column. Conventional phenyl-column.

iolani
Télécharger la présentation

NITRO-PHENYL-CARBAMIDE HPLC STATIONARY PHASES;

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. π-Select π-Select Eluent: 45% methanol Eluent: water Number of theoretical plates for BCD: 1800 plates/m C: 4.7% k’=0.54 Number of theoretical plates for BCD: 32000 plates/m BCD prescribed stop time BCD Conventional phenyl-column Conventional phenyl-column k’=0.25 C: 7.0% HP-betadex Degradation products DS=6 3GL 2-3-4 HP 4GL 2-3-4-5 HP 2GL 1-2-3-4 HP DS=8 1. Benzothiophene 6. Benzo[a]pyrene 5GL 2-3-4 HP 3 2 4 DS=4 2 1GL 1-2-3 HP 1 1 7. Benzo[g,h,i]perylene 3 2. Fluorene 7 5. Pyrene 5 GL 6 3. Fluoranthene 4. Dibenzothiophene DS=6 Ring opening products, linear, substituted maltoheptaoses 1 GL 2 GL 3 GL 4 GL further fragmentation products, smaller substituted maltooligomers 5 GL 6 GL 7 GL DS=8 DS=4 π-Select 250x4 mm * Tyr-Pro-Phe-Atc-NH2 * racemic amino-acid Atc-NH2: 2-amino-decaline-2-carboxylicacid t0 Plate number 16685 asymmetry: 1,189 Z and E LiChrosphere Si 60 250x4 mm C2 Plate number: 5649 asymmetry: 1,261 R and S A* * Cetirizine C1 B* F* E* C3 C* NITRO-PHENYL-CARBAMIDE HPLC STATIONARY PHASES; CD-SCREEN COLUMN FOR ANALYSIS OF CYCLODEXTRIN-DERIVATIVES AND -SELECT COLUMN FOR GENERAL PURPOSE APPLICATIONS Gábor Varga2,Katalin Csabai1, Lajos Szente1, Imre Klebovich3, Krisztina Ludányi3, Julianna Szemán1 1CYCLOLAB Cyclodextrin R&D Laboratory Ltd., Illatos u. 7.,Budapest, H-1097, Hungary, e-mail: szeman.j@cyclolab.hu 2CHIROQUEST Chiral Technologies Development Ltd., Rumbach S. u. 7., Budapest, H-1075, Hungary, e-mail: chiroquest@chello.hu 3SEMMELWEIS UNIVERSITY, Faculty of Pharmacy, Department of Pharmaceutics, Hőgyes E. u. 7., Budapest, H-1092, Hungary, e-mail: ludanyi@hogyes.sote.hu INTRODUCTION STRUCTURE OF THE SELECTOR In our previous work novel stationary phase was prepared by bonding N-(4-nitrophenyl)-carbamide group to the silica gel matrix [1,2]. The new phase has primarily been developed for analysis of cyclodextrins (CDs) and their derivatives. Taking into account the structure of this selector it seemed to be a promising tool for the separation of various families of compounds. Based on theoretical considerationsseveral types of interactions can beexpected with different types of molecules. The main characteristic property of this stationary phase is the essential role of π-π interactions in the retention mechanism [3, 4]. Due to the electron-withdrawing nitro-group in para position, retention forces become stronger and shape selectivity can be significantly better compared to other commercially available phenyl-bonded silica phases [5]. In general, hydrogen bonding was regarded as one of the reasons of poor peak symmetry and low efficiency of chromatographic media. However, the rationally planned, well-defined, non silanol type hydrogen bonding capability can play an important role in the selectivity and retention.Due to the balanced ratio of several types of interactions, it can be supposed that this stationary phase would be suitable both for reversed and normal phase applications, as well. Although the numerous types of p-p active HPLC phases have been already designed and investigated [3, 4], columns having diverse and multiple interacting sites for selectivity tuning can still expect great interest to solve separation problems e.g. in orthogonal chromatographic systems. The aim of this work was to studythe separation potency of 4-nitrophenyl-carbamide stationary phases and to optimize its capability for different separation problems. dipole H-acceptor δ+ H-donors π-acceptor hydrophylic-hydrophobic Illustration of the interaction between the apolar cavity of cyclodextrin and the nitrophenyl-carbamide selector Illustration of electrostatic potential surface difference of 4-nitrophenyl and phenyl-carbamide in complex with phenol and formation of hidrogen bonding PRINCIPLE OF SEPARATION The steric possibilities of the interactions were examined by molecular modelling methods. Both selector and solute molecular models were geometry-optimized using HyperChem MM+ molecular mechanics computational method. The energy minimization (relaxation) of the system consisting of these molecules together was the next step using the same method. The resulted complexes show clearly the presence of one or more hydrogen-bridges, depending on the chemical structure of analyte. Examining the electrostatic potential surfaces of the molecules in these complexes the role of the electron- withdrawing nitro-group in the retention mechanism can be easily understood. RESULTS AND DISCUSSION p-SELECT CD-SCREEN • higher surface coverage compared to the CD-Screen stationary phase, to obtain strong p - p interaction • fully endcapped to eliminate the silanol interactions, to obtain well defined H-bonding • optimized surface coverage, fitting to the size of cyclodextrin molecules • secondary interactions with free silanols to increase the selectivity Comparison of the results of hydroxypropyl-betadex analysis, obtained by European Pharmacopoeia method and CD-Screen column Comparison to phenyl column Polar analytes Apolar, aromatic analytes EP method CD-Screen Using mass-sensitive detector and gradient elution, it can be stated, that approx. 80% of hydroxypropyl-betadex is not eluted from the column before the prescribed stop time. Capacity factor of BCD peak is decreasing continuously due to the accumulation of the sample components on the stationary phase. • Separation of phenol and caffeine • higher retention due to the - interactionsand well defined hydrogen-bonding • residual silanols are eliminated, good peak shape • in pH 2-8 interval the retention time of phenol is relatively high and does not depend on the pH (on conventional phenyl column the retention time of phenol is near to t0at higher pH) • Separation of apolar, aromatic analytes • high retention on the -Select column, in spite of the fact that the carbon-content of this stationary phase is very low • the shape-selectivity and CH2-selectivity are higher, even diethyl-phthalate and biphenyl are well resolved. During 20 min. HP-betadex components are eluted completely. Due to the unique retention mechanism and balanced hydrophilic/hydrophobic interactions, CD-Screen column makes it possible to perform fast, reproducible and high accuracy analysis, furthermore, it provides more detailed information on the sample. Examination of the degradation products of HP-betadex on CD-Screen column Eluent: MeOH-water 30:70 1.: Phenol 2.: Caffeine Eluent: MeOH-water 60:40 1.: Dimethyl-phtalate; 2.: Diethyl-phtalate 3.: Biphenyl 4.: o-Terphenyl CDs and CD derivatives are relatively stable substances, only a few articles can be found on their decomposition. However, to follow the hydrolytical, oxidative or enzymatic decomposition of CDs and their derivatives even in drug formulations can be interesting not only as research subject, but also from practical point of view. Shape selectivity of p-Select columnPolyaromatic hydrocarbons Averaged mass spectra of the small, substituted maltooligomers Stressed HPBCD sample, ELS detection Averaged mass spectra of the intact HPBCD Eluent: MeOH-water 85:15 Eluent: MeOH-water 75:25 Prostaglandine intermediate product Diastereomer peptides Quantity of the degradation products vs. the number of glucose and HP units Extracted ion chromatograms of the degradation products Averaged mass spectra of the linear, substituted maltoheptaoses Normal phase applicationEluent: n-hexane - t-buthyl-methyl-ether 97:3 Eluent: 0.1% TFA in water-0.1% TFA in MeOH 75:25 CONCLUSIONS Cetirizine and related compounds Separation of various families of compounds have been investigated on 4-nitrophenyl-carbamide bonded stationary phase in both reversed and normal phase systems.The new chromatographic media kept its retentive capability even in extremely polar or apolar conditions and proved to be suitable for the separation of different type of substances: p-Select:  separation of polyaromatic hydrocarbons  separation of diastereomers in reversed and normal phase conditions, as well  analysis of basic drugs in acidic conditions CD-Screen:  provides an alternative method for analysis of residual BCD content of HP-betadex  due to the special retention mechanism, intact CD-derivatives and maltooligomers are well separated, hence, development of a stability indicating method is realizable Column: Pi-Select 150x4 mm, 3 μm Eluent: methanol-50 mM KH2PO4 pH 2.2 38:62 Flow: 0.8 ml/min. Temperature: 40 C * Determination of marked impurities is prescribed by Ph. Eur. 5 REFERENCES EXPERIMENTAL [1] PCT Application Number PCT/HU 05/00043, May 30, 2005 [2] J. Szemán, K. Csabai, K. Kékesi, L. Szente, G. Varga; J. Chromatogr. A, 1116, 76-82, (2005) [3]   J. Horak, W. Lindner ; J. Chromatogr. A, 1043, 177-194 (2004) [4]  J. Horak, N. M. Maier, W. Lindner; J. Chromatogr. A, 1045, 43-58 (2004) [5]  I. Caron, C. Elafkir, M. Dreux; Chromatographia 47, 383-390 (1998) [6] A. Salvador, B. Herbretau, M. Dreux; J. Chromatogr. A, 855, 645-656 (1999) Apparatus: Agilent 1050 HPLC system with UV-VISDetector at 205 or 254 nm. For detection of cyclodextrins Evaporative Light Scattering Detector PL-ELS 1000, (Polymer Laboratories) was used (Evaporation: 110°C, Nebulization: 90 °C, Gas flow: 1.2 l/min) Columns: The stationary phases (Hungarian Patent Application Pending 2004) were prepared by ChiroQuest Ltd. Column size: 250 mm x 4.0 mm I.D; Mobile phases: methanol – water or acetonitrile – water; Column temperature: 30 °C; Flow rate: 1.0 ml/min. Malév Hungarian Airlines supports our participation at the conference

More Related