1 / 34

SENCO CONCRETE PINNERS

SENCO CONCRETE PINNERS. Product Information Presentation. GENERAL. General information What fastener to use in what concrete:. Thickness of Material + Penetration Depth = Fastener Length. GENERAL. Cubical pressure Cube of 150x150x150 mm Tested until it breaks to meausure strength

jimbo
Télécharger la présentation

SENCO CONCRETE PINNERS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SENCO CONCRETE PINNERS Product Information Presentation

  2. GENERAL • General information • What fastener to use in what concrete: Thickness of Material + Penetration Depth = Fastener Length

  3. GENERAL • Cubicalpressure • Cube of 150x150x150 mm • Testeduntilitbreaks tomeausurestrength • 2nd number in the concrete classC16/20 • A cube is strongerthan a cilinder, therefor a smaller object is used.

  4. GENERAL • Cylindricalpressure • Cilinder of 150x300 mm • Testeduntilit breaks tomeausurestrength • 1st number in the concrete classC16/20 • A cylinderis weakerthan a cube.

  5. GENERAL • Whatfastenertouse in what concrete • In steel structurebeams (max 650 N/mm2):  alwaysuse premium pins. • Max penetrationdepth = 6.5 mm Premium pins advised

  6. GENERAL • Fastener range various concrete classes

  7. PULL OUT AND TENSION

  8. TO KEEP IN MIND • On site concreting can lead to more pebble-stones on the bottom than on the top side. In such a case, on the ceiling side you need premium pins while on the floor side to can use regular pins.

  9. TO KEEP IN MIND In soft concrete the scoring rate is high. A normal pin is advised. In hard concrete the nail can either bent or deform. This has an influance on the scoring rate. Therefor the premium pin is advised for usage in hard concrete.

  10. TOOLS • SAP40XPSteel/Concrete Pinner • 8 bar! • Unique tool in the market • Lightweight • Trigger- and bottomfire • Long thin nose • 7 nail lengths • Normal and premium Net weight: 3,2 kg Nailcapacity: 42 pins Drive power: 90 J Operatingpress.: 5,5 – 8,3 barFastener range:Collatedpins Diameter: 2,6 – 3,0 mm Fastenerlength: 15 – 40 mm

  11. TOOLS • SGP40Steel/Concrete Pinner • Cordless convenience • Comfort grip • Long thin nose • 7 nail lengths • Normal and Premium • High voltage ignition Net weight: 4 kg Nailcapacity: 42 pins Drive power: 90 JDrive time: 2 shots/second Batterycapacity: 5200 shots Fastener range:Collated pins Diameter: 2,6 – 3,0 mm Fastenerlength: 15 – 40 mm Fuelcell: GC0012

  12. TOOLS • SGP40S (2nd generation): • Short Magazine (22 pins fitting the magazine) • Block Out System • Magazine “Quick Release” • Depth of Drive Control • FIRST toolless “step free” DOD Control on a Concrete Pinner • Easy-Nail-Clear Magazine • Magazine “Quick Release” • Optional long magazine Net weight: 3,9 kg Nailcapacity: 22 pins Drive power: 90 JDrive time: 2 shots/second Batterycapacity: 5200 shots Fastener range:Collatedpins Diameter: 2,6 – 3,0 mm Fastenerlength: 15 – 40 mm Fuelcell: GC0012 INTRODUCTIONQ1/2012

  13. FASTENERS • Regular concrete pins • 7 naillengths(15, 19, 22, 25, 32, 38, 40 mm)5 micron zinc, likenails • Premium pins (Hardened pins for hard concrete) • 7 naillengths(15, 19, 22, 25, 32, 38, 40 mm) 5 micron zinc, likenails

  14. FUEL CELLS • Fuelcells • Single cell GC0012 1.300 shots, 80 ml • Premium fuelcell PC1274 1.300 shots, 80 ml, worksfrom -15°C

  15. FUEL CELLS • Fuelcells • Blisterpack PC1254 750 shots, 2x40 ml + adaptor

  16. ACCESSORIES • Caradaptor PC1196 12Vforchargingyoubatteries in the car • Gas tool cleaning kitFor keepingyour tool in perfect condition

  17. CERTIFICATES? There is no specific standard for concrete fixing. Only test certificates of competetion exist.

  18. GAS TOOLS

  19. NAIL COMPARISON • Overview Senco concrete pins as analternativeforPaslode:

  20. APPLICATIONS Metal(stud) on steel

  21. APPLICATIONS Metal on steel

  22. APPLICATIONS Wood on concrete In concrete minimum distancefrom the edge is > 76,2 mm. Minimum distancebetweennails> 102 mm.

  23. APPLICATIONS Metal(stud) on concrete

  24. APPLICATIONS Metal on stone

  25. WASHER HOLDER • For fastening single shot attachementsPins can fix severalattachementslike: • Washers • Metal clips • Plastic clips • Perfo band

  26. APPLICATIONS Metal on brick. When using the attachment and a washer, the metal profile is still adjustable to make it vertical aligned. After that, fix the profile in the corners.

  27. APPLICATIONS

  28. APPLICATIONS Plastic on concrete.

  29. AIRCONDITIONING APPLICATION

  30. APPLICATIONS For all these you can of course also use a Pneumatic version.

  31. WHAT CAN HAPPEN? • Nailnotdeepenough • Nailtoo long • DOD setting not correct (SGP40S/L) • Increasepressure (SAP40) • Nailtoodeep • Nailtoo short • DOD setting not correct (SGP40S/L) • Reducepressure (SAP40)

  32. WHAT CAN HAPPEN? • Nail bends • Hard concrete / big pebble stones • Steel reinforcement direct under surface • Hard surface (steel) • Nail not deep enough in steel • Steel too hard

  33. WHAT CAN HAPPEN? • Nail won’t stay in material • Base material not thick enough(> 5mm) • Nail breaks • Base material too hard • Nail too long

  34. FAQ’s Q Fit the Senco pins in other tools A Yes, they fit (except for Hilti or unknown brands) Q Fit Senco gas in other tools A Yes, it fits (PC1254 is universal), gas fuel is lubricant and gives no negative result (even more shots are possible) Q Which nail to be used for which application A Use the table (advice, always test on site) Q What service needs to be done on the tools? A Tool needs to be proper managed, and needs cleaning (interval depending on use)