An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Schematic Lighting Design Natty Boh Building Baltimore , Maryland Eric Singley Penn State University Architectural Engineering

  2. Location Natty Boh Building Brewers Hill Baltimore , Maryland Penn State AE Schematic Lighting Proposal Eric Singley

  3. Project Information Natty Boh Building • Building Character: • Old home of the Gunther Brewing Company. • Consists of 6 sections of differing heights. • Declared a historic place in 2002. Building Statistics: • Overall Building Size : 189,550 ft2. • Maximum Height : 9 stories • Multi-purpose: office, storage, residential, commercial Penn State AE Schematic Lighting Proposal Eric Singley

  4. Design Spaces Natty Boh Building • Large Work Space Friday’s Day Care Center • Special Purpose Space Countrywide conference room • Circulation Space Canton Self Storage Lobby • Outdoor Space Parking lot and rear facade Penn State AE Schematic Lighting Proposal Eric Singley

  5. Day Care Center Natty Boh Building • Space Properties • Floor area 4092 ft2. • Exposed ceiling at 14 ft. • Large windows on east and west walls. • Interior partitions dividing kitchen and storage areas. Space Tasks • Primarily play and learning area for small children. • Light kitchen use. Penn State AE Schematic Lighting Proposal Eric Singley

  6. Day Care Center Natty Boh Building Penn State AE Schematic Lighting Proposal Eric Singley

  7. Day Care Center Natty Boh Building • Design Goals • Separate the spaces by function with lighting. • Create a more ‘playful’ atmosphere within the child care area. • Make use of the large windows to introduce daylighting to the space. • Flynn mode – Relaxed. Power Density • 1.5 Watts per square foot allowed. Penn State AE Schematic Lighting Proposal Eric Singley

  8. Day Care Center Natty Boh Building • Design Solution • Drop ceiling to 9’. • Recessed linear fluorescent downlights in walkways. • Recessed CFL downlights in childrens’ area and kitchen. • Under-cabinet lights in kitchen. • LED color spots on columns. Penn State AE Schematic Lighting Proposal Eric Singley

  9. Day Care Center Natty Boh Building • Daylight Integration • Kitchen lights and window- side children’s are lights on their own circuit. Use Photometric sensor with manual override for control. Penn State AE Schematic Lighting Proposal Eric Singley

  10. Lobby Natty Boh Building • Space Properties • Floor Area ≈ 2500 ft2 • Ceiling at 8 ft and 21.5 ft • No windows • Entrances on both levels Space Tasks • Light office work • Display of model storage unit • Sales / Receptionist desks Penn State AE Schematic Lighting Proposal Eric Singley

  11. Lobby Natty Boh Building Penn State AE Schematic Lighting Proposal Eric Singley

  12. Lobby Natty Boh Building • Design Goals • Accentuate the double height ceiling. • Direct customers from entrances to the sales desk. • Provide a non-complex design solution. • Flynn mode – Spacious. Power Density • 1.3 Watts per square foot allowed. Penn State AE Schematic Lighting Proposal Eric Singley

  13. Lobby Natty Boh Building Penn State AE Schematic Lighting Proposal Eric Singley

  14. Lobby Natty Boh Building • Design Solution • CFL downlights over desks. • Recessed CFL downlights in 9’6” portion lower ceiling. • Linear fluorescent wallwash along open wall. • Wallwashers on 21 ft walls to accent their height. Penn State AE Schematic Lighting Proposal Eric Singley

  15. Conference Room Natty Boh Building • Space Properties • Floor Area : 150 ft2 • Ceiling at 8 ft • Conference table with chairs • No windows Space Tasks • Professional and Casual conferences • Possible light video conferencing Penn State AE Schematic Lighting Proposal Eric Singley

  16. Conference Room Natty Boh Building Penn State AE Schematic Lighting Proposal Eric Singley

  17. Conference Room Natty Boh Building • Design Goals • Create a comfortable yet professional environment. • Provide flexibility to accommodate different uses. Including: • Presentations • Video conferencing • Roundtable discussion • Flynn mode – Spacious/Focused Power Density • 1.5 Watts per square foot allowed Penn State AE Schematic Lighting Proposal Eric Singley

  18. Conference Room Natty Boh Building • Roundtable Discussion • Recessed CFL downlights on the conference table. • Linear Fluorescents washing walls and ceiling to provide ambient lighting. Penn State AE Schematic Lighting Proposal Eric Singley

  19. Conference Room Natty Boh Building • Presentation • Ambient lighting remains on. • Reduce the number of downlights on the conference table. • Two spot lamps on podium. Penn State AE Schematic Lighting Proposal Eric Singley

  20. Conference Room Natty Boh Building • Video Conferencing • Dimmed ambient lighting. • Spot lamps on individual faces. • Downlights on table reduced further. Penn State AE Schematic Lighting Proposal Eric Singley

  21. Exterior Natty Boh Building • Space Properties • Ground Area : 37,050 ft2 • Surrounded on 3 sides by buildings • Historically significant Space Tasks • Parking for Natty Boh Building • Entrance to the building Penn State AE Schematic Lighting Proposal Eric Singley

  22. Exterior Natty Boh Building Penn State AE Schematic Lighting Proposal Eric Singley

  23. Exterior Natty Boh Building • Design Goals • Provide sufficient light to allow drivers to read signs and see parking lines. • Call attention to the building entrances. • Achieve 100% Dark Sky compliance. • Maintain similar luminaire appearance. Power Density • 0.3 Watts per square foot allowed Penn State AE Schematic Lighting Proposal Eric Singley

  24. Exterior Natty Boh Building • Design Solution • Spotlight building entrances. • Prevent spill into windows. • Keep light poles on existing islands. Penn State AE Schematic Lighting Proposal Eric Singley