An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SoLID DAQ Camsonne SoLID collaboration meeting November 8th 2013

  2. Outline • Experiment requirements • PVDIS Calorimeter trigger and readout • PVDISsetup,event size and data rates • GEM electronics SRS • SIDIS event size • SIDIS electronics layout • MRPC electronics • Budget • Test stand • To do list • Conclusion

  3. Experiment requirements • PVDIS • Pion contamination • Trigger rate 30 KHz max per sector • 30 independent sectors • SIDIS • Trigger rate • 60 KHz coincidence e pi • 100 KHz singles

  4. Calorimeter trigger

  5. PVDIS calorimeter readout • Need new development of SD and FADC firmware • 100 K$ for R&D and prototyping

  6. PVDIS calorimeter trigger • Send data from one sector to the neighboring sector

  7. PVDIS setup • Shower : 1830 channels • Preshower : 1830 channels • Light Gas Cerenkov : 270 channels • GEM : 4700 strips • Trigger : Shower and Cerenkov • Rate with 30 ns gate : 3e6 * 200e3 * 30e-9= 18 KHz • Rates estimate for 20 KHz

  8. Event size PVDIS • Assume 2 high energy cluster in each sector and all Cerenkov firing for each trigger • Data rates at 20 KHz = 56 MB/s

  9. SRS

  10. SRS • Switch SRS • Cheaper per channel cost • Less crates • Higher data transfer rate

  11. SIDIS • Detectors • Forward • Calorimeter preshower + shower • Scintillator • Light Gas Cerenkov • Heavy Gas Cerenkov • Large Angle • Calorimeter shower • Scintillator • GEM • 5 planes

  12. SIDIS, J/Psi requirements • SIDIS : 60 KHz coincidence e/pi, 80 KHz singles • J/psi : triple coincidence e , e+,e- • Plan • FADC integrated readout • GEM with deconvolution one sample readout • In theory should be able to reach 100 KHz

  13. Event size SIDIS • GEM occupancy with deconvolution : 1.2 KBytes • Other detectors : ~ 1.9 KBytes • Data rate 100 KHz with 3.1 Kbytes event size 310 MB/s Could take more but need reduce with L3

  14. SIDIS, J/psi • Calorimeter electron trigger as PVDIS • Send cluster number to GTP • Coincidence • APV25 : on chip convolution one sample readout • FADC readout : zero suppress 10 % MIP for calorimeter readout time and integral • Might consider waveform for SPD and preshower depends on final trigger rate

  15. SIDIS trigger • Electron trigger • Shower + LC + SPD + MRPC : Forward angle • Shower + SPD : Large angle • Pion trigger • Shower + HC + SPD • Shower • J/psi trigger • Shower ( 3 clusters above threshold ) + LC + SPD + MRPC

  16. SIDIS electronics layout

  17. Electronics layout SIDIS

  18. FADC occupancy

  19. MRPC • Question about electronics and funding • Solution in house / commercial electronics • 2 input registers : 2K$ • 4 V1290 CAEN High Resolution TDC : 11 K$ • Price per sector : 44 K$ • Total price : 1.4 M$ ( only readout no FE ) • Funding request from Tsinghua University • Either use this solution or develop custom module

  20. DAQ cost estimate

  21. Additionnal cost • 100 K$ R&D prototyping SD • 50 K$ shield house electronics • Total around 3 M$

  22. L3 Farm • Base on Hall D estimate • Driven by PVDIS • Assuming 30 KHz • 390 cores for non tracking option • 1500 cores with tracking

  23. Operation costs • Cables : 300 K$ • Racks : 15 K$ • Tape : 600 K$

  24. Test stand • Test trigger logic • Test max trigger rates • Test electronics with real detector signals • Test GEM readout max performance • 4 FADC, 1 CTP and 2 VXS crates • 1 SRS from UVA and 1 INFN MPD readout

  25. Things needed for director review • Tes trigger logic and FADC performance • PVDIS • Occupancy in Calorimeter • L3 data reduction scheme • SIDIS trigger rates • MRPC, LGC, HC , SPD simulation • Simulation digitization • SIDIS GEM occupancy from G4 • SIDIS rates from G4 simulation • MRPC development custom electronics • APV25 high rate, test with SRS • L3 reduction factor and ressource needed test algorithm • MaPMT test

  26. Conclusion • PVDIS doable and cost reasonable now calorimeter rate down : 18 KHz • SRS : saves cost on crates and per channel, more performant data transfer GEM event size manageable • SIDIS most like should be able to take all single triggers by reading only integral and one sample per trigger for GEMs • Need to test at high rate