Instrumentation needs

Instrumentation needs. M. Meddahi. General layout Requested instruments and precision LTI CNGS Beam instrumentation layout. TT60. Dynamic range. TI 2 and TI 8 beam :. From one pilot to 4 trains of 72 bunches. 5 10 9 (pilot) to 4.9 10 13 p/extraction (ultimate).

juro
Télécharger la présentation

Instrumentation needs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Instrumentation needs M. Meddahi • General layout • Requested instruments and precision • LTI • CNGS • Beam instrumentation layout Instrumentation needs LTI and CNGS Controls Review

  2. TT60 Instrumentation needs LTI and CNGS Controls Review

  3. Dynamic range TI 2 and TI 8 beam : From one pilot to 4 trains of 72 bunches 5 109 (pilot) to 4.9 1013 p/extraction (ultimate) 2 extractions of 10.5 ms in a 6s cycle 2.4 1012 p (SU) to 3.5 1013 p/extraction (ultimate) CNGS : T1 : Slow extracted beam Instrumentation needs LTI and CNGS Controls Review

  4. Beam Position monitors Precision required :+/- 0.1 mm BPM radius 30 mm Within 20 mm : precision : 0.3% --> +/- 0.1 mm Outside : precision : 1% --> 0.3 mm resolution : 1 per mil --> 0.03 mm Select : all bunches individually (same electronics as LHC) 2 processes running in parallel (one accumulating the average data, one for a particular bunch or all bunches individually). + CNGS : beam angle accuracy : 0.1 mrad Instrumentation needs LTI and CNGS Controls Review

  5. Intensity measurements Beam current transformers : Very good absolute precision difficult Relative 1 % Also Intensity measurements possible with BPM if both X and Y axes equipped : +/- 1% precision in radius of 15 mm +/- 2 % in radius of 20 mm Some BPMs will be equipped in both planes Interesting tool to check the intensity along the line, where losses might occur Equip the line with both BCT and few X/Y BPMs Instrumentation needs LTI and CNGS Controls Review

  6. Beam loss monitors Ionization Chamber : Sensitivity/resolution ~3000 e- /primary charges Very broad dynamic range (0.1% of pilot/ultimate) 30 BLMs in each TI 18 in TT41 Instrumentation needs LTI and CNGS Controls Review

  7. Profile measurements : Optics checks Emittance measurements Precision: Pilot (Alumina screen) s ~ 5% Others : Gaussian beam s ~ 4% Non-Gaussian: rms with better precision Measure the emittance taking these precisions into account (+ error on Twiss) Selection: Measure pilot, integrate a whole batch. If more required : one selected bunch, a selected train, ------> need to equip screen with PM or electronic shutter Instrumentation needs LTI and CNGS Controls Review

  8. SPS extraction Septa Kickers 418 417 419 Bumper 1 Bumper 2 Bumper 3 Bumper 4 x (m) - measurement of the bumped beam position - simultaneous horizontal & vertical orbit acquisition - Extracted beam profile & position at the entrance and exit of septum. s(m) Instrumentation needs LTI and CNGS Controls Review

  9. Extraction LSS4 and LSS6 - BPM : Special BPM in front of septum magnet Aperture radius : 100 …110 mm required precision & linearity : 100 … 200 mm over 50 % of aperture, i.e. 0.1 … 0.2 % ------> factor 20 …. - OTR : Use of OTR being investigated - BLM: Important for setting up (low intensity), for post mortem for the extracted beam, for interlocking to beam dump for circulating beam (bad bumper setting or septum position). Instrumentation needs LTI and CNGS Controls Review

  10. TT40 and start of TI 8 TED CNGS OTR4 OTR5 OTR1 OTR2 OTR3 BCT Modified BPCK (LHC and CNGS beam) BPM (2-in-4 scheme) BLM Instrumentation needs LTI and CNGS Controls Review

  11. TI 8 Dn H/V = 600 BPM (2-in-4 scheme) OTR6 OTR7 OTR8 Instrumentation needs LTI and CNGS Controls Review

  12. Injection into LHC MSI MKI TED OTRSMSI OTREMSI OTR11 OTR10 OTRSMKI OTREMKI TED : final check point before injection into LHC BCT OTR9 BPM BLM Instrumentation needs LTI and CNGS Controls Review

  13. Injection into LHC TCDD H- Plane BPM Proposed Added BPM BLM OTR Instrumentation needs LTI and CNGS Controls Review

  14. TT60 and TI 2 TED TED MSI MKI OTR4 OTR12 OTR5 OTR11 OTR6 OTR9 OTR1,2,3 OTR7 OTR10 OTRSMSI OTR8 OTREMSI BCT Modified BPCK BPM (2-in-4 scheme) OTRSMKI OTREMKI BLM Instrumentation needs LTI and CNGS Controls Review

  15. Profiles BLM BLM Last 200 m Position Intensity Profiles Profiles Profiles BLM BLM Instrumentation needs LTI and CNGS Controls Review

  16. Summary Instrumentation needs LTI and CNGS Controls Review