1 / 24

Biofeedback System for Improved Athletic Training

Biofeedback System for Improved Athletic Training. ECE-498 Matt Statton Advisor: Professor Hanson. Introduction. Goals of athletic training Muscle hypertrophy through stimulation Muscle fatigue during a specified repetition range Maximum motor unit recruitment inducing muscle hypertrophy

karah
Télécharger la présentation

Biofeedback System for Improved Athletic Training

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Biofeedback System for Improved Athletic Training ECE-498 Matt Statton Advisor: Professor Hanson

  2. Introduction • Goals of athletic training • Muscle hypertrophy through stimulation • Muscle fatigue during a specified repetition range • Maximum motor unit recruitment inducing muscle hypertrophy • Benefits of effective training • Increased results • Injury prevention • Many people do not know how to properly fatigue their muscles • Personal trainers

  3. Biofeedback • How it works • Raises awareness of unconscious physiological activities • Control • Adjustment • Uses • Anxiety and stress • Hypertension • ADHD

  4. Project Proposal • Electrical signals produced by muscles can be used as an indicator of muscle fatigue • Giving users the ability to recognize their level of muscle fatigue will lead to improved athletic training • Maximizing muscle fatigue • Decreasing injury

  5. Design Requirements • Measure electrical signals from muscles • Analyze signal to determine level of muscle fatigue • Determine threshold at which muscle fatigue occurs • Provide feedback response to user

  6. Design Requirements • Measure electrical signals from muscles • Electromyography • Intramuscular vs. surface electromyography • Cost effectiveness • Measurement accuracy

  7. Electromyography Figure 1: Electromyogram from http://www.dataq.com/images/article_images/emg1.jpg

  8. Design Requirements • Measure electrical signals from muscles • Electromyography • Analyze signal to determine level of muscle fatigue • Analog-to-digital conversion • Measure absolute and relative maximum amplitudes of signal • Determine threshold at which muscle fatigue occurs • Provide feedback response to user

  9. Electromyograph • Important components • MAX666CPA Voltage Regulator • LT1494 operational amplifier, A = 1 • Provides virtual ground at Vcc/2 • INA106 differential amplifier, A = 10 • High common-mode rejection ratio Figure 2: Electromyograph circuit based on circuit diagram from http://instruct1.cit.cornell.edu/courses/ee476/FinalProjects/s2005/bsm24_ajg47/website/website/index.htm

  10. Circuit Creation • LPKF ProtoMat C20S Circuit Board Plotter Figure 3: LPKF Circuit Board Plotter from http://www.lpkf.com/_images/757-lpkf-protomat-h100.jpg

  11. EagleCAD Figure 4: EagleCAD schematic of electromyograph circuit Figure 5: EagleCAD board file created from schematic

  12. CircuitCam / BoardMaster Figure 6: CircuitCam circuit board diagram Figure 7: BoardMaster circuit board diagram

  13. Printed Circuit Figure 8: Front of printed circuit board Figure 9: Back of printed circuit board

  14. Design Requirements • Analyze signal to determine level of muscle fatigue • Determine threshold at which muscle fatigue occurs • Provide feedback response to user

  15. Electromyograph Signal Analysis • Silicon Labs C8051F020 microcontroller • On-board analog-to-digital converter • ADC0 = 12-bit • ADC1 = 8-bit • Programmable in C

  16. Electromyograph Signal Analysis Figure 10: Flow chart of electromyograph signal analysis program

  17. Electromyography Figure 11: Contraction and relaxation of muscles of the upper arm from http://www.zoodu.com/uploads/images/2006-08-10/vlt9QAl2A5.jpg

  18. Results Figure 13: Electromyogram of fully contracted and relaxed biceps muscle (Range = 250 mV) Figure 12: Electromyogram of relaxed biceps muscle (Range = 30 mV)

  19. Results Figure 14: Electromyogram of slightly contracted and relaxed biceps muscle (Range = 130 mV) Figure 15: Electromyogram of fully contracted, slightly contracted, and relaxed biceps muscle

  20. Continuing Work • Signal processing • More sophisticated user interface • LCD screen • Buttons • Threshold calibration • Low battery indicator • Electrode leadwire connectors • FDA regulations

  21. Conclusions • The 8051 microcontroller is not yet accurately measuring absolute and relative maximum amplitudes of the signal • Electrical signals were successfully measured using surface electromyography • Continuing work will be done to successfully analyze the signal and provide users a feedback response based on muscle fatigue

  22. Acknowledgements • Professor Hanson • Professor Hedrick • Ben Bunes

  23. Bibliography Association for Applied Psychophysiology and Biofeedback. 4 June 2008 <http://www.aapb.org/i4a/pages/index.cfm?pageid=1>. Gariety, Arthur and Madoff, Benjamin. ECE 476 Final Project: Wireless Electromyograph. 13 November 2008 <http://instruct1.cit.cornell.edu/Courses/ee476/FinalProjects/s2005/bsm24_ajg47/website/website/index.html>. U.S. National Library of Medicine, National Institutes of Health. Electromyography. 4 June 2008 <http://www.nlm.nih.gov/medlineplus/ency/article/003929.htm>. http://www.dataq.com/images/article_images/emg1.jpg http://www.lpkf.com/_images/757-lpkf-protomat-h100.jpg http://www.winning.co.za/images/exImage6.jpg http://www.zoodu.com/uploads/images/2006-08-10/vlt9QAl2A5.jpg

  24. Questions?