An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ECS Status Xavier Vilasís Cardona Xvc-CaloComissioning Meeting

  2. Outline • Calorimeter ECS people • SPECS buses and Control PCs • High Voltage Control Xvc-CaloComissioning Meeting

  3. Calorimeter ECS people Xvc-CaloComissioning Meeting

  4. SPECS buses and Control PCs Xvc-CaloComissioning Meeting

  5. SPECS buses and Control PCs Distribution of control PCs in racks Rack D2C03:  CALO - MUON http://lhcb-online.web.cern.ch/lhcb-online/installation/D2DCS_Racks/D2DCS_Racks_layout.htm Xvc-CaloComissioning Meeting

  6. High Voltage Control Anatoli Konoplyanikov (Xvc) Xvc-CaloComissioning Meeting

  7. Test the database scheme Hardware Cond DB Control PCs reconstruction Conf DB PVSS Cs calib results • Test PVSS can control the HV sources • Load HV channel data from ASCII file • Test connection to Configuration DB PVSSarchive Mon+calib farm UPDATES(Connectivity, HV, delays, …) ASCII files ? Offline procedures CALO DB Xvc-CaloComissioning Meeting

  8. SPECS slave mezzanine for interconnection with the LHCb ECS system. Control Logic board for interface between the SPECS slave and others functional parts of Distribution board. 40 channels HV control signal generation card. 16 channels LED control signal generation card. HV and LED control signal distribution board SPECS bus HV Out 1-40 RJ45 DAC DU2 ADC HV mez Analog MX HV Out 41-80 RJ45 FPGA DAC HV mez HV Out 81-120 SPECS mezzanine DAC HV mez Digital MX HV Out 121-160 SPECS bus to chaining boards Parallel Bus DAC HV mez HV Out 161-200 ACTELFPGA DAC Serial Bus HV mez LED Out 1 - 16 DAC Control logic mezzanine LED mez + 5 V - 5 V Power regulators and over current protection circuits + - 7 V + 80 V + 80 V Xvc-CaloComissioning Meeting

  9. Outputs 200 outputs for the CW base control voltage distribution in range from 0 to 5 V with 12 bit precision. 16 outputs for the LED intensity control signal distribution in range from 0 V to +5 V with 12 bit precision. 8 outputs of the stabilized LV and +100 V power supplies for feeding the 8 groups of the CW base. Inputs SPECS bus for interconnection with ECS. Power lines from external power supplies. HV and LED control signal distribution board Xvc-CaloComissioning Meeting

  10. PVSS Control of the HV signal distribution board • At present the board is successfully controlled by a PVSS program interfacing the SPECS bus • HV DAC values can be correctly set and retrieved. • Using an automated script • Through an operator panel • Importing data from an ASCII file Xvc-CaloComissioning Meeting

  11. PVSS Control of the HV signal distribution board Board description using FwHw tool Xvc-CaloComissioning Meeting

  12. PVSS Control of the HV signal distribution board Sample Operator Panel Xvc-CaloComissioning Meeting

  13. PVSS Control of the HV signal distribution board Importing data from an ASCII file (tab separated) Xvc-CaloComissioning Meeting

  14. HV board Control – work in progress • Connection to the Configuration Database • New tools shall be released by the online group. • Inserting the HV control board into the ECS control hierarchy • Defining the Device Unit associated to the board by the fwFSM tool. • Designing definitive operator panels and refining scripts and file formats. Xvc-CaloComissioning Meeting