An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Resilient Modulus Testing and Startup Procedures A Product Line

  2. PRESENTATION OBJECTIVES What is the Resilient Modulus (Mr) Testing and Startup Product Line • Why Mr Testing and the Startup Procedures are Important • Development of the Mr Startup Procedure • How to Conduct the Mr Startup Procedure • Who Should Use the Mr Testing and Startup Product Line and Why • How to Get Information on the Mr Testing and Startup Product Line

  3. FHWA LTPP Protocol P46, Resilient Modulus of Unbound Granular Base/Subbase Materials and Subgrade Soils LTPP Mr Start-up Procedure Product Line FHWA-RD-96-176, Resilient Modulus of Unbound Materials Laboratory Startup and Quality Control Procedure • FHWA Video Tape Series • Laboratory Resilient Modulus Testing: Is This the Right Time? • Laboratory Resilient Modulus Testing: Startup and Quality Control Procedure • Laboratory Resilient Modulus Testing: Sample Preparation and Test Procedure

  4. Resilient Modulus Lab Tests Videotape 1 “Laboratory Resilient Modulus Testing: Is This the Right Time?” • 8 minutes • Explains resilient modulus and what it is used for. • Describes developments that have made the testing more consistent and easier to adopt. • Target Audience: Administrators and engineers

  5. Resilient Modulus Lab Tests Videotape 2 “Laboratory Resilient Modulus Testing: Startup and Quality Control Procedure” • 15 minutes • Gives detailed definition of resilient modulus. • Explains the procedure developed to ensure that a lab is set up properly to conduct the test procedure and to collect accurate test results. • Target Audience: Laboratory managers and technicians

  6. Resilient Modulus Lab Tests Videotape 3 “Laboratory Resilient Modulus Testing: Sample Preparation and Test Procedure” • 13 minutes • Describes each step in the resilient modulus test procedure, including how to prepare soil and aggregate samples. • Target Audience: Lab managers and technicians

  7. PRESENTATION OBJECTIVES • What is the Resilient Modulus (Mr) Testing and Startup Procedure Product Line • Development of the Mr Startup Procedure • How to Conduct the Mr Startup Procedure • Who Should Use the Mr Testing and Startup Product Line and Why • How to Get Information on the Mr Testing and Startup Product Line Why Mr Testing and the Startup Procedures Are Important

  8. Resilient Modulus 101 • AASHTO Definition: • “A measure of the elastic property of soil recognizing certain non-linear characteristics.” • Resilient Modulus = Mr • Resilient Modulus = elastic modulus (mod. of elasticity) • Resilient Modulus = stress/strain • Resilient Modulus = stiffness • Resilient modulus  strength

  9. Typical Elastic Modulus Values (ksi) • PCC 3,000 – 6,000 • Asphalt Concrete 500 – 2,000 • Crushed Stone 20 – 40 • Silty Soils 5 – 20 • Clayey Soils 5 – 10

  10. Usefulness of Resilient Modulus • Used to define fundamental material properties • Used in constitutive models • Used to predict stress, strain, and displacement • Used to develop performance models • Used in current AASHTO pavement design guide • Used in mechanistic design approach

  11. The Resilient Modulus Startup Procedure • Verifies the ability of equipment and personnel to perform resilient modulus testing • Developed by LTPP to ensure consistent, repeatable and accurate results • Implemented in FHWA, state DOTs, academia, and industry

  12. Benefits Of Mr Startup Procedure • Procedure useful to anyone conducting resilient modulus testing • Prepared for resilient modulus of soils but can be applied to asphalt • Generic procedure useful to anyone performing testing using servo-hydraulic test systems (i.e. complex modulus, creep, etc.)

  13. PRESENTATION OBJECTIVES • What is the Resilient Modulus (Mr) Testing and Startup Procedure Product Line • Why Mr Testing and the Startup Procedures are Important • How to Conduct the Mr Startup Procedure • Who Should Use the Mr Testing and Startup Product Line and Why • How to Get Information on the Mr Testing and Startup Product Line Development of the Mr Startup Procedure

  14. Testing and Protocol History • 1987 - Strategic Highway Research Program (SHRP) adopts resilient modulus testing • 1990 - Initial protocols developed • 1991 - Resilient Modulus testing began • 1992 - FHWA assumes leadership of LTPP • Early 1993 - SHRP Resilient Modulus Testing Ends

  15. Data Problems:1993/1994 - SHRP data • Serious flaws found in the data • Large amount of data deemed unusable • Probable cause • faulty electronics • mechanical problems • operator error

  16. Causes of Data Problems • Sample loading non-symmetrical • Sample loaded too long • Deformation occurs prior to loading * • Deformation impulse shorter than load impulse * • Deformation fluctuation • Deformation “flat-line” or clipping phenomenon

  17. High Testing Variability and Low Confidence • Poor precision and bias • SHRP precision and bias testing yielded 100% variation between labs, 50% within lab • Many practitioners have no confidence in test results • Equipment standardization lacking

  18. The Mr Testing Challenge • Significant modulus testing remained to be completed • Need for equipment and operator verification procedure established Result • P46 test procedure revised to reflect lessons learned • P46 startup procedure developed to address equipment/operator issues

  19. The Startup Procedure Development Objectives • Develop a simple, efficient and inexpensive methodology to verify equipment performance and accuracy of a laboratory • Verify laboratory ability (personnel/equipment) to conduct P46 Resilient Modulus Tests

  20. PRESENTATION OBJECTIVES • What is the Resilient Modulus (Mr) Startup Procedure Product Line • Why Mr Testing and the Startup Procedure is Important • Development of the Mr Startup Procedure • Who Should Use the Mr Startup Procedure and Why • How to Get Information on the Mr Startup Procedure How to Conduct the Mr Startup Procedure

  21. Equipment • Oscilloscope • Function Generator • Strain Indicator • LVDT Modulator/Oscillator (optional) • NIST Traceable Proving Rings • Micrometer Calibrator • NIST Traceable Pressure Gauge

  22. The 3-Phase Startup Process • Verification of Electronic System • Verification of Mechanical System • Verification of Laboratory Ability to Conduct P46 Resilient Modulus Test

  23. Electronic System VerificationElectrical Method (Method 1) • Focuses on the signal path from the transducers to the digitized output data • Input: an electrical signal with known frequency and amplitude • Output: acquired digitized data • Compares input and output signals for a range in frequency

  24. Electronic System VerificationMechanical Method (Method 2) • Focuses on the signal path from the transducers to the digitized output data • Input: a “reference” LVDT and the machine LVDT are exercised mechanically with known frequency and amplitude • Output: acquired digitized data and visual reference to oscilloscope • Compares input and output signals for a range in frequency • Note: new procedure, not documented in FHWA-RD-96-176, simpler than Method 1

  25. Electronic System VerificationComponents Checked • Analog signal conditioning • Digitized signal processing • Transducers (load cells, LVDTs) • Signal filters • Various layers of data acquisition and control software • Acceptance Criteria • Matched input to output delays < .5 msec • Amplitude constant from 2 to 50 hz

  26. The 3-Phase Startup Process • Verification of Electronic System • Verification of Mechanical System • Verification of Laboratory Ability to Conduct P46 Resilient Modulus Test

  27. Mechanical System Verification • Focuses on the performance capability of the laboratory equipment • Uses NIST traceable calibrated proving rings and other measurement devices

  28. Mechanical System Verification Components • LVDT Calibration • Load Cell Zero • Load Cell Calibration Certificates • Load Cell Cal. Verification • Dynamic Response • Phase Angles • Triaxial Pressure Chamber