Zirconium O2 Sensor Testing

Zirconium O2 Sensor Testing. Passing Results Minimum Voltage (Artificially Full Lean) 0V – 175mV Maximum Voltage (Artificially Full Rich) 800mV – 1V Rise Time (Snap Throttle) < / = 100mS (from 175mV – 800mV). RPM. O2S. STFT. IPW. TPS. MAF. = 50mV. = 175mV. = 50mV. = 800 mV.

maik
Télécharger la présentation

Zirconium O2 Sensor Testing

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Zirconium O2 Sensor Testing Passing Results Minimum Voltage (Artificially Full Lean) 0V – 175mV Maximum Voltage (Artificially Full Rich) 800mV – 1V Rise Time (Snap Throttle) < / = 100mS (from 175mV – 800mV)

  2. RPM O2S STFT IPW TPS MAF

  3. = 50mV

  4. = 175mV = 50mV

  5. = 800 mV = 175mV = 50mV

  6. = 800 mV = 175mV Fail! = 50mV

  7. Test Question! • Using a DSO, a technician tests an O2 sensor for “rise time” by snapping the throttle and freezing the frame. The technician has set up the DSO time scale for 200mS per division, with 5 subdivisions each. When measured at the specified voltage levels, the rise time between the cursors was 3 subdivisions. What is the measured time difference, and does this O2 sensor pass the rise time test? The time difference is 120ms and it does not pass the test