1 / 7

Load Settlement Issues

Load Settlement Issues. Floyd Trefny Amtec. Disclaimer. The content of this presentation does not represent the typical actions or inactions of the Texas Steel Companies and is presented from the experience of the author when discussing load response products the consumers.

Télécharger la présentation

Load Settlement Issues

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Load Settlement Issues Floyd Trefny Amtec

  2. Disclaimer The content of this presentation does not represent the typical actions or inactions of the Texas Steel Companies and is presented from the experience of the author when discussing load response products the consumers

  3. How Do Price Sensitive Loads React to Price Changes • Most Industrial and Commercial Loads look to the ERCOT postings of the Load Zone LMP as the primary indicator of eventual settlement point price • Prices are posted on the MIS every time SCED runs • Dispatch of an interruption is managed in several different ways • A Load Entity has a central control center that tells individual loads within its facilities when to turn off or back on • A Load Entity has a relationship with its REP or NOIE that tells the load when to take actions • REP may keep any energy settlement proceeds from the load interruption • Load Entity may be only paid a capacity credit on its charge for energy for giving the right to interrupt to the REP • Load Entities may share value provided with the REP for each interruption • A Load Entity has multiple sub-processes within its plant that several supervisors independently determine if the ERCOT posted prices meet management directives of when and under what conditions they may interrupt • Usually each independent process must judge the need for interruption based on its current operating state of its process • Results in different timing and different strike prices to interrupt given operating conditions • Highly variable Time Delays from when the price is posted to when the load actually shuts down

  4. How Do Price Sensitive Loads React to Price Changes • Dispatch of an interruption is managed in several different ways (continued) • Large Commercial facilities each represented by a single contract for service from an REP, individually determine if actions should be taken • Many facilities (over 100) are under contract across multiple load zones • Not all the facilities in a contract are price sensitive and significant diversity will exist across different Load Zone • Special hedging methods are used to manage these loads • Residential Loads who are price sensitive are usually managed by automated processes at each home • Input from the REP central dispatch • Homeowner override issues

  5. How Do Price Sensitive Loads React to Price Changes • When to return to service after an interruption is usually a more complex decision that when to interrupt • Loads usually always have some minimum time following an interruption that it must for safety reasons stay off regardless of current LMP prices • Must-Down times can run from 10 minutes to several hours • Most loads that are controlled by individual supervisors, do not have access to ERCOT reserve postings or have the training necessary to accurately predict prices

  6. Diversity in Load Response to Prices • Typically, the largest individual plant loads in a large industrial facility are no more than 20-40 Mw with many less than 5 Mw. A large plant may have six or more large loads where each is individually controlled • Interruption of these individual loads is quite diverse with all having many different LMP strike prices to interrupt and many different re-start constraints to come back on • This phenomenon provides for smooth interruptions of small amounts of load as prices increase provided the load zone price does not just blow through from moderate prices to high prices in one or two SCED intervals • Price acceleration controls in penalty factor curves may be useful in providing moderation in responses

  7. Load Response Effect on Regulation • When ERCOT system load increases; so typically do prices • Increases in ERCOT system load are managed by Reg-Up and then reset with issuance of new Base Points • As individual price thresholds are reached, individual loads respond thus limiting further Reg-Up requirements • Provided the price increase is moderate, then the diversity in load response usually has the effect of reducing Reg-Up • When ERCOT system load decreases, so typically do prices • Decreases in ERCOT system Load are managed by Reg-Down • The diversity in load response to decreases in price are significant due to the large variations in minimum time to return to service and other constraints

More Related