1 / 60

Chp.12 Cont. – Examples to design Footings

Chp.12 Cont. – Examples to design Footings. Example.

mckile
Télécharger la présentation

Chp.12 Cont. – Examples to design Footings

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chp.12 Cont. – Examplesto design Footings

  2. Example Design a square footing to support a 18 in. square column tied interior column reinforced with 8 #9 bars. The column carries an unfactored axial dead load of 245 k and an axial live load of 200 k. The base of the footing is 4 ft. below final grade and allowable soil pressure is 5 k/ft2 Use fc = 3 ksi and fy = 60 ksi

  3. Example 1 Assume a depth of footing. (2 ft or 24 in.) The weight of concrete and the soil are:

  4. Example 1 The effective soil pressure is given as:

  5. Example 1 Calculate the size of the footing:

  6. Example 1 Calculate net upward pressure:

  7. Example 1 Calculate the depth of the reinforcement use # 8 bars with a crisscrossing layering.

  8. Example 1 Calculate perimeter for two-way shear or punch out shear. The column is 18 in. square.

  9. Example 1 Calculate the shear Vu The shape parameter

  10. as is 40 for interior, 30 for edge and 20 for corner column Example 1 Calculate d value from the shear capacity according to 11.12.2.1 chose the largest value of d

  11. Example 1 The depth of the footing can be calculated by using two way shear

  12. Example 1 The second equation bo is dependent on d so use the assumed values and you will find that d is smaller and a = 40 Actual (d =14.02324 in.) bo=128.93 in

  13. Example 1 The depth of the footing can be calculated by using one-way shear

  14. Example 1 The depth of the footing can be calculated by using one-way shear The footing is 19.5 in. > 13.9 in. so it will work.

  15. Example 1 Calculate the bending moment of the footing at the edge of the column

  16. Example 1 Calculate Ru for the footing to find r of the footing.

  17. Example 1 From Ru for the footing the r value can be found.

  18. Example 1 Compute the area of steel needed The minimum amount of steel for shrinkage is The minimum amount of steel for flexure is

  19. Example 1 Use a #7 bar (0.60 in2) Compute the number of bars need Determine the spacing between bars

  20. Example 1 Check the bearing stress. The bearing strength N1, at the base of the column, 18 in x 18 in., f = 0.7 The bearing strength, N2, at the top of the footing is

  21. Example 1 The bearing strength, N2, at the top of the footing is

  22. Example 1 Pu =683 k < N1, bearing stress is adequate. The minimum area of dowels is required. Use minimum number of bars is 4, so use 4 # 8 bars placed at the four corners of the column.

  23. Example 1 The development length of the dowels in compression from ACI Code 12.3.2 for compression. The minimum ld , which has to be greater than 8 in., is

  24. Example 1 Therefore, use 4#8 dowels in the corners of the column extending 19 in. into the column and the footing. Note that ld is less than the given d = 19.5 in., which is sufficient development length.

  25. Example 1 The development length, ld for the #7 bars for the reinforcement of the footing. There is adequate development length provided.

  26. Example 1 - Final Design

  27. Example 2 Design a footing to support a 18 in. square column tied interior column reinforced with 8 #9 bars. The column carries an unfactored axial dead load of 245 k and an axial live load of 200 k. The base of the footing is 4 ft. below final grade and allowable soil pressure is 5 k/ft2 Use fc = 3 ksi and fy = 60 ksi. Limit one side of the footing to 8.5 ft.

  28. Example 2 Assume a depth of footing. (2 ft or 24 in.) The weight of concrete and the soil are:

  29. Example 2 The effective soil pressure is given as:

  30. Example 2 Calculate the size of the footing:

  31. Example 2 Calculate net upward pressure:

  32. Example 2 Calculate the depth of the reinforcement use # 8 bars with a crisscrossing layering.

  33. Vu =150.7 k in short direction Example 2 The depth of the footing can be calculated by using the one-way shear (long direction)

  34. Example 2 The depth of the footing can be calculated by using one-way shear design The footing is 19.5 in. > 18.8 in. so it will work.

  35. Example 2 Calculate perimeter for two-way shear or punch out shear. The column is 18 in. square.

  36. Example 2 Calculate the shear Vu The shape parameter

  37. as is 40 for interior, 30 for edge and 20 for corner column Example 2 Calculate d from the shear capacity according to 11.12.2.1 chose the largest value of d.

  38. Example 2 The depth of the footing can be calculated for the two way shear

  39. Example 2 The third equation bo is dependent on d so use the assumed values and you will find that d is smaller and a = 40 Actual (d =14.032 in.) bo=128.173 in

  40. Example 2 The depth of the footing can be calculated by using the two way shear

  41. Example 2 Calculate the bending moment of the footing at the edge of the column (long direction)

  42. Example 2 Calculate Ru for the footing to find r of the footing.

  43. Example 2 Use the Ru for the footing to find r.

  44. Example 2 Compute the amount of steel needed The minimum amount of steel for shrinkage is The minimum amount of steel for flexure is

  45. Example 2 Use As =8.36 in2 with #8 bars (0.79 in2). Compute the number of bars need Determine the spacing between bars

  46. Example 2 Calculate the bending moment of the footing at the edge of the column for short length

  47. Example 2 Calculate Ru for the footing to find r of the footing.

  48. Example 2 Use Ru for the footing to find r.

  49. Example 2 Compute the amount of steel needed The minimum amount of steel for shrinkage is The minimum amount of steel for flexure is

  50. Example 2 Use As =9.36 in2 with #6 bar (0.44 in2) Compute the number of bars need Calculate the reinforcement bandwidth

More Related