1 / 13

Oliver Kugeler

Oliver Kugeler. Progress of the installation of a quadrupole resonator for thin films testing at HZB. Overview. Purpose of the QPR: RF characterisation of superconducting thin films Activities at HZB to date : Setting up the infrastructure ( Scope of this talk ). Dedicated

melosa
Télécharger la présentation

Oliver Kugeler

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Oliver Kugeler Progress of the installation of a quadrupole resonator for thin films testing at HZB

  2. Overview • Purposeofthe QPR: • RF characterisationofsuperconductingthinfilms • Activitiesat HZB todate: • Setting uptheinfrastructure • (Scopeofthistalk)

  3. Dedicated Insert for QPR • Verticaltest stand • PresentlymanufacturedatKriosystems (Wroclaw, PL) • Tobeinstalled in late April 2014 • Magneticshielding, NoLN2precooling, • 400 literdewaroperation, 1.8 K

  4. HZB SRF infrastructureupgrade HoBiCaT GunlabBeamline Gun Vertical Test stand Integration intoHoBiCaTbunker UseCryogenics, RF infrastructure, InterlockingsystemfromHoBiCaT

  5. Pumpingports Couplerports • HZB Quadrupole resonator 1.8 K lHe Operating frequencies: 433 / 866 / 1300 MHz (TESLA) Resonator body (Nb) Thickened quadrupolerods (Nb) Sample Coaxialgap Frame (SS, Ti) Calorimetrychamber (large domainNb)

  6. Design optimization • Fullparameterizationwith CST • Maximizingfiguresofmerit • (PhDwork Raphael Kleindienst) * fractionoffieldexposurebetween sample andresonator

  7. QPR manufactureatNiowave (Sep 2013) Large grain meterial

  8. QPR cleaning at JLAB • Cavityshippedto JLAB • BCP, HPR and First RF testsatJLAB throughBerlinPro MOU Weld protection Ultrasonicrinsing BCP Doneby Andrew Burrill

  9. Cavitypreparation 600°C bakeoutfor 12 hours PhotosbyAndrew Burrill Leak check in He atmosphere

  10. First RF tests • Passbandspectrummeasuredwithnetworkanalyzer; looks okay • Quadrupole mode off by 8 MHz (still withinamplifierbandwidth) 433 MHz 866 MHz Makeshiftloopantenna RF testingsetup 1.3 GHz PhotosbyAndrew Burrill

  11. LLRF andcalorimetry • 433 MHz RF componentsobtained • 433 MHz PLL built • Data acquisitionhardwaresetup • Temperaturecontrollerinstalled • Cernoxsensorsobtained • Heaterwithminimizedmagneticfieldbuilt • Magneticcoupler (loopantenna) built • DC coilformagneticmeasurementsbuilt

  12. Modifiedthermometrychamber (Master thesis Sebastian Keckert) Removable sample M2.5 Helicoil • Exploded view • Advantage: • reduced sample dimensions(Ø 75 mm, h=12 mm) • noweldingrequired • geometricaladjustmentofsample possible • Risk: • Cleanlinessissues (no separate vacua in cavityandcalorimetrychamber) Matching surfaces Double sided CF100 flange

  13. outlook • First coldtestat JLAB • Qualify QPR at HZB • Identifythin film producers / techniques / materials • Start measurements