Test Monitoring Center Report to the Mack Test Surveillance Panel

Test Monitoring Center Report to the Mack Test Surveillance Panel. December 3, 2001 Miami, FL. T-8/T-8E/T-9 Reference Oil Testing Summary. October ‘01 Report Period: T-8 / T-8E 8 tests 3 labs / 4 stands 4 accepted for calibration 1 invalid (missed soot window) 3 aborted

Télécharger la présentation

Test Monitoring Center Report to the Mack Test Surveillance Panel

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Test Monitoring CenterReport to the Mack Test Surveillance Panel December 3, 2001 Miami, FL

  2. T-8/T-8E/T-9 Reference Oil Testing Summary • October ‘01 Report Period: T-8 / T-8E • 8 tests • 3 labs / 4 stands • 4 accepted for calibration • 1 invalid (missed soot window) • 3 aborted • Projected to miss soot window: 1 • Failed Injection Pump: 1 • Broken Camshaft: 1 • No T-9 Reference Activity

  3. T-8/T-8E/T-9Reference Oil Testing Summary • T-8/T-8E Current Industry Alarms • None. • T-9 Current Industry Alarms • ALW • EWMA Severity warning, mild • No indication if a “true” alarm • One test • Data is eight months old

  4. T-10 Reference Oil Testing Summary • October ‘01 Report Period • 40 tests • 5 labs / 12 stands • 33 matrix tests / 7 calibration tests /6 accepted for calibration • 1 aborted – fuel dilution • Current Period (April ’02) • 2 tests, accepted for calibration • Number of Calibrated T-10 Stands: 13 • T-10A Flush and Run Stands: 2

  5. T-10 Reference Oil Testing Summary • Current T-10 Industry Alarms • None.

  6. Items for Surveillance Panel Consideration • T-8E Relative Viscosity • CI-4 uses 100% of DIN Shear Loss • Results differ in severity and precision from CH-4 relative viscosity. • Not currently monitored for either calibration or severity adjustments

  7. Items for Surveillance Panel Consideration • T-8E Relative Viscosity • Add to T-8E as third parameter, monitor for SA’s only (non-critical for stand calibration)???????? • Avoids calibration by oil category (!) • Database can be easily developed using existing T-8E data: RV100 = RV50 [ (Vu/2Vs) + 0.5 ]

  8. Items for Surveillance Panel Consideration • Liner Wear Step Measurements • 2001 Round Robin Identified differences in wear step measurements between labs and measurement devices.

  9. Items for Surveillance Panel Consideration • Liner Wear Step Measurements • Per conference call discussion • Liners from a previous round robin are being remeasured to help determine which lab / device has shifted. • Liner measurement workshop is to be held.

  10. Results of Liner Re-Measurements Lab A – Talysurf Lab D - PDI