An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Quorum Sensing Stephanie Lo Harvard iGEM 8/6/07

  2. After Overnight at 37C

  3. Goals • Characterize JT (sender/receiver construct in one) • Is quorum-like activity occurring? • If so, at what OD is it detectable? • Optimize ratio of separate sender-receiver cells

  4. JT Assay Initial Diluted Sample OD = 0.3 Fluorescence = 600 Saturated Overnight Culture OD = 1.5 Fluorescence = 3000

  5. JT Assay Initial Diluted Sample OD = 0.3 Fluorescence = 600 Growth OD = 0.3 Fluorescence < 600 Second (immediate) dilution OD = 0.1 Fluorescence = 200

  6. Quorum/growth dilution Fluorescence OD

  7. Expected Results: Fluorescence per OD Fluorescence / OD After overnight growth Saturated overnight Before 1st run After 1st run After 2nd run

  8. Characterizing JT 7/31

  9. Characterizing JT 7/31

  10. Characterizing JT 7/31

  11. Characterizing JT 7/31

  12. Characterizing JT 7/31

  13. Characterizing JT 8/1

  14. Characterizing JT 8/1 Fluorescence results as expected, growth curve a concern

  15. Characterizing JT 8/2 New Approach? • Past attempts: • Plate reader stopped on regular basis, endpoint fluorescence and OD read • New approach: • Split initial dilution in two • Leave plate reader on kinetic fluorescence • Manually read OD regularly at photospectrometer

  16. Characterizing JT 8/3 Plate Reader Endpoints: 3rd Attempt

  17. Characterizing JT 8/3 Unexpectedly scarce absolute fluorescence growth

  18. Characterizing JT 8/3

  19. Characterizing JT 8/3 Is this an issue involving lack of growth?

  20. Characterizing JT 8/3 ODs after overnight indicate saturation

  21. Characterizing Sender/Receiver Systems Supernatant LB CELLS

  22. Characterizing Sender/Receiver Systems Expected Results Above quorum Absolute Fluorescence or Fluorescence / OD Below quorum Amount supernatant (OHHL) added

  23. Characterizing Sender/Receiver Systems 8/1 Growth Curves: T02 induced

  24. Characterizing Sender/Receiver Systems 8/1

  25. Characterizing Sender/Receiver Systems 8/1 Amount of SI added Amount of SI added Not shown: JT Fl/OD after overnight = 3630

  26. Better Characterization of Sender/Receiver System • More samples with different amounts of supernatant added • Different types of supernatant: RACE, SE

  27. Characterizing Sender/Receiver Systems 8/3 Amount supernatant added

  28. Characterizing Sender/Receiver Systems 8/3 Fluorescence over OD after Overnight Expected trend, wrong magnitude? Amount supernatant added Not shown: Nondiluted JT: 990 RFU/OD

  29. Characterizing Sender/Receiver Systems 8/3 Increase in fluorescence is not drastic

  30. Characterizing Sender/Receiver Systems 8/3 Fluorescence over OD gives puzzling results