1 / 27

LIFT,ESCALATOR AND MOVING WALKS

LIFT,ESCALATOR AND MOVING WALKS. ARC 05005512. LIFT,ESCALATOR AND MOVING WALKS. WHAT IS LIFT? Lift is a type of vertical transport equipment that efficiently moves people or goods between floors or levels of a building, vessel, or other structure. Open Lift (bubble type ).

nitara
Télécharger la présentation

LIFT,ESCALATOR AND MOVING WALKS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LIFT,ESCALATOR AND MOVINGWALKS ARC05005512

  2. LIFT,ESCALATOR AND MOVINGWALKS WHAT ISLIFT? Lift is a type of vertical transport equipment that efficiently moves people or goods between floors or levels of a building, vessel, or otherstructure. • Open Lift (bubbletype) • Closed Lift (typicaltype) TYPES OFLIFTS Passengerlift Goodslift Strecherlift Glasslift Capsulelift Hydrauliclift

  3. LIFT,ESCALATOR AND MOVINGWALKS • HYDRAULICLIFT • A lift where the vertical movement is done by hydraulicforce. • They use an undergroundcylinder • common for low level buildings with 2–5 floors (up to 6–8floors) • have speeds of up to 200 feet/minute (1 meter/second) • GLASSLIFT • give passengers a visually stimulating ride betweenfloors. • The car walls must be constructedwith • laminated glass • the glass lift consist of entrance area and a viewingarea

  4. LIFT,ESCALATOR AND MOVINGWALKS PASSENGER LIFT:A lift designed for the transport ofpassengers. Goodslift

  5. LIFT,ESCALATOR AND MOVINGWALKS • FIREMAN'SLIFT • For buildings having height of 15m ormore • described below: • Lift car floor area of not less than 1.44sq.m • Loading capacity of not less than 544 kg (8 persons). • Lift landing doors shall have minimum fire resistance of twohours. • The lift speed shall be 1.0 m/s or more • reachable time to the top floor from the ground (or entrance) floor within 60seconds.

  6. LIFT,ESCALATOR AND MOVINGWALKS • DUMB WAITER • total inside ,height and capacity not exceeding 0.9 m2, 1.25 mand 225kg • used for carrying materials and noperson. Dumbwaiter

  7. LIFT,ESCALATOR AND MOVINGWALKS • minimum inside platform area 1275 mm wide x2000 mmlong • minimum clear opening width of 1050mm, • an ambulance stretcher (minimum size 600mm • wide x 2000 mm long) in its horizontalposition. HOSPITALLIFT

  8. LIFT,ESCALATOR AND MOVINGWALKS • Components oflift • Controlroom • Guides • Liftcar • Lift cardoor • Carrail • Counterweight • Controlpanel • Liftpit • Buffer • Hoist way • Hoistrope • Ventilationwindow • Flexiblecable • Drivecrank

  9. LIFT,ESCALATOR AND MOVINGWALKS • LIFT CAR :Platform where passengers or goods istransported. • Passenger elevators shouldbe located at the circulation coreof thebuilding. • minimum width and depthof the car shall be 2000mm • and 1291 mm.(for wheelchair) • Height of the entrance to the lift car shall not be less than 2m. • The rails shall be at least 38 mm clear of thewalls • nominal height of 800 mm from the floor.

  10. LIFT,ESCALATOR AND MOVINGWALKS • alarm button and emergency stop switch shall be at a height of 890mm, • highest floor button no higher than 1.37 m from thefloor. • letters or numbers shall be a minimum of15 • mmhigh • control buttons shall be at least 19 mm min dimensions. • standby power within60 secondsafter • failure of normalpower. • in fire emergency, DO NOT USE LIFT. USE EXIT STAIRS.This • sign shall be in letters not less than 12 mmhigh.

  11. LIFT,ESCALATOR AND MOVINGWALKS LIFT SHAFT:Constructed with reinforcedconcrete. • counterweight: • To grip the liftcar • Reduce the powerof generator • Reduce the braketo • stop the carlifts GEARLESSMOTOR GUARD RAIL: hold the lift from crashing down if the ropebreak.

  12. LIFT,ESCALATOR AND MOVINGWALKS • The width of lift machine room shall be equal to be lift (minimum of 2500mm) • The height shall not be less than 2.30 m throughout under the liftingbeam • the trap door shall not be less than 1.0 m x 1.0m • machine room entrance is less than 1.5m SHAFT PIT – the bottom end ofthe • Lift pits having depth more than 1.6m • shall beprovided shaft is calledpit.

  13. LIFT,ESCALATOR AND MOVINGWALKS where A is width oflift Two CarArrangement

  14. LIFT,ESCALATOR AND MOVINGWALKS where A is width oflift Three CarArrangement

  15. LIFT,ESCALATOR AND MOVINGWALKS Four CarArrangement

  16. LIFT,ESCALATOR AND MOVINGWALKS Six CarArrangement where A is width oflift where A is width oflift

  17. LIFT,ESCALATOR AND MOVINGWALKS where A is width oflift Eight CarArrangement

  18. LIFT,ESCALATOR AND MOVINGWALKS • WHAT ISESCALATOR? • An escalator is a moving staircase – a conveyor transport device for carrying people between floors of abuilding. • designed on an incline of 27.3, 30,35 degrees. • If the height is more than 6mthan • incline of 27.3 should begiven • The speed of the escalator, shall not be more than 0.63 m/s for 30o angle ofincline • and 0.50 m/s for 35o angle ofincline.

  19. LIFT,ESCALATOR AND MOVINGWALKS TYPES OFESCALATOR: MULTIPARALLEL PARALLEL: These typeof escalator go up and down simultaneously. CRISS-CROSS: They stacks the escalators that go in single direction and reduces structural space requirement.

  20. LIFT,ESCALATOR AND MOVINGWALKS TYPES OFESCALATOR: UP” ESCALATOR NEXT TO STAIRCASE :It is preferred that staircases be located adjacent to the escalator if the escalator is the primary means of transport between floors. SPIRAL TYPE ESCALATORS: Theseare used to enhance the architectural beauty and to save thespace.

  21. LIFT,ESCALATOR AND MOVINGWALKS • COMPONENTS OF THEESCALATOR: • LandingPlatforms. • Truss. • Tracks. • Steps. • Handrail. • Escalator Exterior(Balustrade). • Drivesystem. • Auto-LubricationSystem. • Brakingsystem. • Safety devices. • Electrical & ControlSystems.

  22. LIFT,ESCALATOR AND MOVINGWALKS • Handrail- • operating speed is less than 0.35m/s • the handrail width not more than75mm • Each moving handrail height notless • than 300mm. • BALUSTRADE- • The thickness of theglass • shall not be less than 6mm. • Height 680 mm vertically abovethe nose line of thesteps, balustrade DECK BOARD- These are used for preventing clothing from getting caught and other such problems. deckboard

  23. LIFT,ESCALATOR AND MOVINGWALKS • TRUSS– • The truss is a hollow metalstructure • that bridges the lower and upperlandings. • The ends of the truss are attached to the top and bottom landing platforms via steel or concretesupports. • FLOORPLATE- • flush with the finishedfloor steps • in front of the escalator shall be a minimum of 3m. • STEPS- • Trade shall not be less than 400mm • Riser shall not be more than 220mm. • front and back edges of the steps are each connected to twowheels.

  24. LIFT,ESCALATOR AND MOVINGWALKS • Standard transportation speed ranges between 0.5 to0.65m/s • For a speed of 0.5m/s the theoreticalcapacity • is: • 600mm step width -4500 persons perhour • 800mm step width -6750 persons perhour • 1000mm step width -9000persons/hour • escalators having a vertical rise not more than 6m. • Minimum head room shall notbe • less than 2.3m.

  25. LIFT,ESCALATOR AND MOVINGWALKS • Moving Walk-A power driven, horizontal or inclined, continuously movingconveyor • used for carrying passengers, • horizontally • an incline up to a maximum of 15 degree.

  26. LIFT,ESCALATOR AND MOVINGWALKS • operating speed is less than 0.35 m/s or the width is no more than 530mm. • normal handrail height not lessthan 300mm