1 / 13

STYLITIS-50

STYLITIS-50. Most advanced datalogger for wind energy assessment. 1. MAIN FEATURES. 19 channels, and specifically:

Télécharger la présentation

STYLITIS-50

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. STYLITIS-50 Most advanced dataloggerfor wind energy assessment

  2. 1. MAIN FEATURES • 19 channels, and specifically: - 9Counter Channels (types: SIN, #40 (SIN with filter), TTL or REED). - 10 Analog Channels: 2 voltage inputs with no gain (0~5V sensors supported). 4 voltage inputs with gain as well: 2 with gain=10, 2 with gain=200. 2 selectable as voltage inputs with no gain or current inputs (for 4~20mA sensors) 2 only as differential inputs PT-100 • Sampling once per second. • Math statistics (Average, Min, Max, Sdv) recorded per interval (from 1 min to 1 hour). • Recording in internal memory of 512KB (buffer) or in Removable Compact Flash Cards (up to 2GB) for practically unlimited data storage. • Built-in Sym-o-net modem, for GSM/GPRS connections and encrypted data emailing. • 1 serial communication port (DTE). • 1 auxiliary serial port (DCE). Connect an additional RS‐232 device or sensor, like an ultrasonic anemometer, to communicate with it remotely, via the same Sym-o-net modem. When communicating with the device, communication with the datalogger is not possible. • Unique sensor supervisor technology. Check the power consumption of each sensor separately. Shows fault cause without visiting site. Ability to isolate faulty sensors. • Fixed precision voltage excitation outputs, for counter sensorsupply: 1x2.5V, 9x5V and 2x11V. • Pulsed precision excitation outputs, for analog sensor supply: 1x5V and 1x1mA.

  3. 2. PHYSICAL FORM Stylitis-50 features: • Control • LCD display and 16-key numeric keyboard local, full operation except data download. • Total control and more user friendly operation via our Stylitis Explorer software. • Serial Port/Communication: 1serial communication port (DTE), suitable for: • Local Operation, by connecting it to a PC. • Internet/LAN operation, by connecting it to an external Serial-to-Ethernet Adaptor. • Remote operation is possible via its built-in modem (for GSM/ GPRS operation and encrypted data emailing). An external modem (of other type, not requiring a SIM card) can also be connected to the serial port. • ENCLOSURE:ΙΡ65 sealed. • DIMENSIONS: 27 x 17 x 11 cm, WEIGHT: 1,5kg. • INPUT CONNECTORS: Removable screw terminal strips on right side.

  4. 3. COMPATIBLE MEASUREMENTS AND SENSORS • Input channels supported: • Counters. Type: SIN, #40 (SIN with filter), TTL or REED • Analog Voltage Inputs with no gain. 0~5V sensors supported • Analog Voltage Inputs with gain. (gain=10 or gain=200) • Analog Current Inputs (for 4~20mA sensors) • Differential PT100 inputs • Some indicative measurementsand related sensors are: • Wind Speed and Direction (Anemometers and Wind Vanes). • Temperature and Humidity (Thermometers, Hygrometers and Thermo-hygrometers) • Barometric Pressure (Barometers) • Solar Radiation (Pyranometers) • Water Depth and pH (Water Depth and pH sensors) • Active Energy (Single phase and 3-phase) • AC and DC Voltage and Current (AC and DC Current and Voltage meters) …and many more

  5. 4. COMMUNICATION METHODS • Communication with Stylitis-50 can be achieved in various ways • The datalogger can be used: • On its own, for local and remote (GSM/GPRS) operation • With a serial-to-Ethernet adaptor, connected to its serial port, for LAN/ internet operation • With other types of modems (which do not require a SIM card), connected to its serial port • The communication methods are presented more analytically in the next chapters

  6. 5. LOCAL AND ETHERNET OPERATION • Locally RS-232 • Via Ethernet (local network or the internet) RS-232 (An ADSL connection is required only for connections to the internet) Stylitis-50 Serial-to-Ethernet LAN/ internet ADSL Router Stylitis-50

  7. 6. GSM/GPRS OPERATION GSM Network • Via a GSM data call RS-232 • Via GPRS, using a cheap Dynamic IP SIM Card (via DiamesonServer) Virtual COM (Diameson Gateway is Symmetron’ssoftware server connecting all dynamic IP SIM devices) 3. Via GPRS, using a static IP SIM Card Virtual COM GSM modem Stylitis-50 GPRS Network Diameson Gateway Internet Stylitis-50 GPRS Network Internet Stylitis-50

  8. 7. REMOTE OPERATION WITHOUT A SIM CARD • Via Satellite RS-232 RS-232 • Via RF Modems. RS-232 RS-232 (Access one or more loggers without a SIM card within a limited distance-usually a few km) Iridium modem Iridium modem Stylitis-50 Radio Modem Radio Modem Stylitis-50

  9. 8. STYLITIS EXPLORER SOFTWARE Stylitis Explorer is Stylitis-50’s free operating software. Via Stylitis Explorer you can: • Create Site folders and Connections. Each datalogger has its unique folder, while multiple (different types of) connections can be created for the logger. The different connection types correspond to the communication methods, discussed before. • Modify its Setup: Channel parameters, recording interval, GPRS settings, etc. • Specifically, channel parameters can be set in 3 ways: manually via a virtual keyboard (same buttons and appearance as the real one), manually via a more user friendly interface (Easy Setup) or automatically (via Easy Setup again), by selecting a specific sensor from Stylitis Explorer’s sensor library • View the logger’s status: Instant parameters, such as the current file, the recording time remaining, etc. • View the instant channel values. • Enable/ disable data acquisition to create data files, stored in the removable Compact Flash card (up to 2 GB). Files are not stored in the 512KB internal memory (buffer) when acquisition is disabled. • Download data files, which are stored in the Compact Flash card, or the current file of the buffer, in compressed form. They are stored and decompressed automatically in the site folder, to be viewed via a text editor. From the Compact Flash you can download: the recent file (a new file begins), the card’s directory (to speculate the files’ size, number, start and end date), or a previous file. • Adjust the built-in Sym-o-net modem settings, for GSM/GPRS connections and encrypted data emails. • View an Online plot of the channel values. All samples are plotted (every second). • Manage the downloaded data files offline. • For single data files: view the channels’ plot and statistics, apply new Slope and Offset values in retrospect • For a folder’s files: check the integrity of the files (check for missing or duplicate records or if the interval is the same for all files) and view the data availability within the months and years.

  10. 9. STYLITIS EXPLORER: SCREEN SHOTS Online plot Data file plot Easy Setup Download files and card directory

  11. 10. AUTOCONNECT SOFTWARE • As stated before, data files can be downloaded manually, via Stylitis Explorer, via any connection. • However, data download, along with other actions as well, can be preformed automatically, in a regular basis, via the additional free software AutoConnect. • The datalogger can perform a different action each weekday: • Download Data: The current data file, either from the buffer or from theCompact Flash. There is an option to clear the buffer in the end or not. • Download Status: Instant parameters, such as the current file, the recording time remaining, etc. • Download Display. Get the instant channel values. • Update Captum. Captum is a free service to present real-time and historical data of Symmetron data loggers on the World Wide Web. Captum Plot • The selected action of a weekday can be performed once a day at a specific selected time, or infinite connections can be made that weekday every as many minutes as you wish. • Besides editing the auto connections (like in Stylitis Explorer) via AutoConnect’sinterface, you can: • View a list of all your automatic connections and execute one or more manually. • Check each connection’s latest status, ie if it succeeded, or failed and why. • View the date and time of last connection and last successful download for each one.

  12. 11. MAIN APPLICATIONS AND CONCLUSION Stylitis-50 could be used in: • Wind energy assessment. • Solar plant monitoring. • Weather stations. • Electrical Measurements. • Tank level monitoring …and many more Summing up, its main advantages are: • Specialized in wind measurements. • Adequate channel number covering most needs (can measure speed/ direction in 9 heights). • Variety of sensor types supported, along with suitable voltage and current excitation outputs. • Unique sensor supervisor technology. Ability to isolate faulty sensors, if power consumption is high. • Variety of communication methods. • Free operating and automatic connection software.

  13. about Symmetron Our company was founded in 1989 by experienced engineers and evolved as a major manufacturer of dataloggers and supplier of measurement equipment. Symmetron is certified according to the ISO9001 quality system and we are proud to have deployed thousands of measurement systems worldwide. Address 1, Antikythiron Street 153 44 Gerakas Greece tel: +30-210-6034002fax: +30-210-6034003 email: info@symmetron.grwww.symmetron.gr

More Related