1 / 17

The Particle Refrigerator

The Particle Refrigerator. A promising approach to using frictional cooling for reducing the emittance of muon beams. Tom Roberts Muons, Inc. Introduction. Frictional cooling has long been known to be capable of producing very low emittance beams

sage-finch
Télécharger la présentation

The Particle Refrigerator

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Particle Refrigerator A promising approach to using frictional coolingfor reducing the emittance of muon beams. Tom Roberts Muons, Inc. Particle Refrigerator

  2. Introduction • Frictional cooling has long been known to be capable of producing very low emittance beams • The problem is that frictional cooling only works for very low energy particles, and its input acceptance is quite small in energy: • Antiprotons: KE < 50 keV • Muons: KE < 10 keV Key Idea: Make the particles climb a few Mega-Volt potential, stop,and turn around into the frictional cooling channel. This increases the acceptance from a few keV to a few MeV. • So the particles enter the device backwards; they come back out with the equilibrium kinetic energy of the frictional cooling channel regardless of their initial energy. • Particles with different initial energies turn around at different places. • The total potential determines the momentum (energy) acceptance. Particle Refrigerator

  3. Frictional Cooling • Operates at β ~ 0.01 in a region where the energy loss increases with β, so the channel has an equilibrium β. • In this regime, gas will break down – use many very thin carbon foils. • Hopefully the solid foils will trap enough of the ionization electrons in the material to prevent a shower and subsequent breakdown. Experiments on frictional cooling of muons have beenperformed with 10 foils (25 nm each). FrictionalCooling IonizationCooling Particle Refrigerator

  4. Simulation of a Thin Carbon Foil, Muons Variance is large Operating Point 2.4 kV/foil < 2.2 keVStopsin Foil Useful Range G4beamline / historoot Compared to antiprotons, the useful range is smaller, and theoperating point is closer to the upper edge of the useful range. Particle Refrigerator

  5. Muon Refrigerator – Diagram 10 m Solenoid 1,400 thin carbon foils (25 nm), separated by 0.5 cm and 2.4 kV. μ− climb the potential, turn around, and come back out via the frictional channel. … μ− In(3-7 MeV) 20cm μ− Out(6 keV) -5.5 MV Gnd Resistor Divider HV Insulation First foil is at -2 MV, so outgoing μ− exit with 2 MeV kinetic energy. Solenoid maintains transverse focusing. Device is cylindrically symmetric (except divider); diagram is not to scale. Remember that 1/e transverse cooling occurs by losing andre-gaining the particle energy. That occurs every 2 or 3 foilsin the frictional channel. Particle Refrigerator

  6. Refrigerator Output – KERight after first foil Particle Refrigerator

  7. Refrigerator Output – tRight after first foil Particle Refrigerator

  8. Refrigerator Tout vs KeinRight after first foil Output in the Frictional Channel “Lost” muonsat higher energy Particle Refrigerator

  9. Background: Muon ColliderFernow-Neuffer Plot R.B.Palmer, 3/6/2008. Particle Refrigerator

  10. Why a Muon Refrigeratoris so Interesting! Difference is just input beam emittance RefrigeratorTransmission=12% RefrigeratorTransmission=6% G4beamline simulations,ecalc9 emittances. (Same scale) Particle Refrigerator

  11. Muon Losses Higher transverse emittance input beam was due to larger σx’, σy’. Larger-angle particles have larger β at turn-around, and can already be out of the frictional regime at the first foil. Challenge: can we use all those higher-energy muons? Particle Refrigerator

  12. Dominant Loss Mechanism • The dominant loss mechanism is particles losing too little energy in a foil and leaving the frictional-cooling channel. • This happens much more frequently for muons than for antiprotons. • Many are lost right at turn-around. Incoming(going right) One μ+Track Outgoing(going left) Turn Around Lost In the FrictionalChannel (going left) Particle Refrigerator

  13. Those “Lost” muons Have Also Been Cooled “Lost” muonsTransmission=65% This can surely be optimized to do better. (Same scale) Particle Refrigerator

  14. Comments onSpace charge • Be wary in applying the usual rules of thumb • Low normalized emittance is achieved by low momentum, not small bunch size: σx 25 mm σy 25 mm σz 673 mm <pz> 1.1 MeV/c (β=0.01) • Clearly a careful computation including space charge is needed. Particle Refrigerator

  15. An Inexpensive ExperimentUsing Alphas • Shows feasibility andmeasures transmission,not emittance or cooling • Uses two 50 kV suppliesto keep costs down. • The source must bedegraded to ~100 keV. • Hopefully the sourcecollimation will avoid theneed for a solenoid (asshown). This is just a concept −lots of details need tobe worked out. Vacuum Chamber 100 nm Carbon Foils Typical Alpha Track Detector Collimated Alpha Source (degrader?) Resistor Divider -50 kV Supply +50 kV Supply This is a simple, tabletop experiment that should fit within an SBIR budget. Particle Refrigerator

  16. LOTS more work to do! • Investigate space charge effects • Investigate electron cloud effects • Will electrons multiply in the foils and spark? • Investigate foil properties, handling, etc. • Engineer the high voltage • Will foils degrade or be destroyed over time? • Design the input/output of the refrigerator (kicker, bend?) • Design the following acceleration stages There are many unanswered questions, but the sameis true of most current cooling-channel designs. Particle Refrigerator

  17. Conclusions • This is an interesting device that holds promise to significantly improve the design of a muon collider. • Much work still needs to be done to validate that. Particle Refrigerator