1 / 10

Preliminary Results from XP401

Preliminary Results from XP401. S.M. Kaye NSTX Physics Meeting 19 April 2004. XP401: H-mode Confinement Scaling. Objectives of first phase of experiment Establish current and power scaling of long-pulse H-mode confinement I p =0.62 – 1.2 MA, P NBI = 1 to 3 sources (at 90 keV)

Télécharger la présentation

Preliminary Results from XP401

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Preliminary Results from XP401 S.M. Kaye NSTX Physics Meeting 19 April 2004

  2. XP401: H-mode Confinement Scaling • Objectives of first phase of experiment • Establish current and power scaling of long-pulse H-mode confinement • Ip=0.62 – 1.2 MA, PNBI = 1 to 3 sources (at 90 keV) • Experimental approach • Attempted with DND plasmas at k~1.9, d~0.45 (identity comparison with MAST) • Power threshold too high to perform power scan (3-3.5 MW) • Attempted with LSN at modest k, d • Discharge disrupted at 3 source level • Success with long-pulse, “PF1b” LSN discharges • k=2-2.2, d=0.5-0.7 • “Nearly” DND

  3. XP401: H-mode Confinement Scaling • Preliminary results • Power scans with 1, 1.5 (1 source modulated), 2 and 3 performed at all currents • Did not include 1.5 source shots in preliminary results • Power thresholds near 1-1.5 source level • Type III ELMs observed for first time • Highest current, power plasma disruptive • Confinement at 1 source (with A or B) comparable; delayed L-H transition with Source C • Stored energy exhibits almost linear dependence on plasma current at fixed Ptot • Power scaling is LESS than P-0.5 at fixed Ip • Still need to sort out differences between fixed parameter scans and statistical results

  4. Ip = 0.8 MA, 2 Sources

  5. Type III ELMS Observed 0.62 MA 1.5 Sources 2 Sources 3 Sources

  6. Ip Dependence For 2 Sources 1.2 MA 1.06 MA 0.8 MA 0.62 MA

  7. Ip Dependence For 3 Sources 1.06 MA 0.8 MA 0.62 MA

  8. Ip Scaling of Confinement Time HL ~ IP0.74

  9. Power Scaling HL ~ P-0.57

  10. Effect of Fueling Location, Duration

More Related