1 / 34

One-Dimensional, Steady-State Conduction with Thermal Energy Generation

Alternative Conduction Analysis . Standard approach is useful for constant k and A.Alternative method may be needed for changing k(T) or A(x) as long as qx is constant.Refer to Figure 3.6, A(x) is a function of x, k(T) changes with Tqx = -k(T)*A(x)*(dT/dx)=constant. . Alternative Conduction Anal

solana
Télécharger la présentation

One-Dimensional, Steady-State Conduction with Thermal Energy Generation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. One-Dimensional, Steady-State Conduction with Thermal Energy Generation Chapter Three Section 3.5, Appendix C

    2. Alternative Conduction Analysis Standard approach is useful for constant k and A. Alternative method may be needed for changing k(T) or A(x) as long as qx is constant. Refer to Figure 3.6, A(x) is a function of x, k(T) changes with T qx = -k(T)*A(x)*(dT/dx)=constant

    3. Alternative Conduction Analysis

    4. Alternative Conduction Analysis qx = -k(T)*A(x)*(dT/dx)=constant The last eqn. applies to uniform A and constant k. 1-D, Steady-state, no heat generation

    5. Examples 3.5 (pages 133-135) The diagram shows a conical section fabricated from pyroceram. It is of a circular cross section with the diameter D = ax, where a = 0.25. The smaller end at x1=50 mm and large end at x2=250 mm. The end Ts are T1=400K and T2=600K, while the lateral surface is well insulated. Derive an expression for the T(x) in symbolic form, assume 1-D condition. Sketch the T distribution. Calculate the heat rate qx through the cone.

    6. Examples 3.5

    7. Examples 3.5 Known: Conduction in circular conical section having a diameter D=ax, where a=0.25. Find: 1. T(x), 2. Heat transfer rate qx Schematic:

    8. Examples 3.5 Assumptions: Steady-state; 1-D conduction in x direction; No internal heat generation; Constant properties. Properties: Table A.2 (page 988), pyroceram (500K): k=3.46 W/mK

    9. Examples 3.5 Analysis: 1-D, steady-state without heat generation Where A = ? D2/4=? a2x2/4, separating variables,

    10. Examples 3.5 Analysis: Hence: Although qx is a constant, yet, an unknown. We need the second b.c. to evaluate qx.

    11. Examples 3.5 Analysis: At x=x2, T=T2 (2nd b.c.)

    12. Examples 3.5 Analysis: Substituting numerical values into the foregoing eqn. Comments: The heat transfers in the direction of decreasing temp.

    13. Examples 3.6 (pages 138-141)

    14. Examples 3.6 Known: Liquid N2 is stored in a spherical container that is insulated and exposed to ambient air Find: 1 The rate of heat transfer to N2 2 The mass rate of N2 boil-off Schematic:

    15. Examples 3.6

    16. Examples 3.6 Assumptions: Steady-state; 1-D conduction through radial direction; Negligible resistance to heat transfer through the container wall and from the container to N2; Constant properties; Negligible radiation exchange between outer surface of insulation and the surroundings.

    17. Examples 3.6 Properties: From Table A.3 (page 936), evacuated silica powder (300K): k=0.0017W/mK Analysis: The thermal circuit involves a conduction and convection resistance in series and is of the form:

    18. Examples 3.6 Analysis: From Eqn. 3.36 From Eqn. 3.9 Heat transfer rate to the liquid N2:

    19. Examples 3.6 Analysis: Heat transfer rate to the liquid N2: Hence

    20. Examples 3.6 Analysis: q = 223/(17.02+0.05)=13.06 W (2). Energy balance for a control surface about N2

    21. Examples 3.6 Analysis: The loss per day (liters/day):

    22. Examples 3.6 Comments: Rt,cond >>Rt,conv, to reduce the boil-off, need to look for better or thicker insulator. Daily loss is about 10.8% of the total volume in the container. Doubling thickness of insulator can reduce 45% loss. If a specific boil-off rate is required, insulator thickness can be determined to meet the needs.

    23. One-Dimensional, Steady-State Conduction with Thermal Energy Generation Chapter Three Section 3.5, Appendix C

    24. Implications

    25. Conduction with Heat Generation Plane Wall with Thermal Energy Generation Steady-state, 1-D conduction through x direction

    26. The Plane Wall

    27. Plane wall (cont.)

    28. Radial Systems

    29. Radial systems (cont.)

    30. Problem: Nuclear Fuel Rod

    31. Problem: Nuclear fuel rod (cont.)

    32. Problem: Nuclear fuel rod (cont.)

    33. Problem: Nuclear fuel rod (cont.)

    34. Problem: Nuclear fuel rod (cont.)

    35. Problem: Nuclear fuel rod (cont.)

More Related