1 / 7

EMU Upgrade Report

EMU Upgrade Report. Dick Loveless University of Wisconsin. 12 October 2012. ME4/2 Chambers. Chamber f actory is operating reliably Chamber production rate ~1/week Completed 19 chambers (out of 67 needed) Chambers 211 – 218 in 2 month HV test Chambers 219 and 220 in assembly area . 211.

starr
Télécharger la présentation

EMU Upgrade Report

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EMU Upgrade Report Dick Loveless University of Wisconsin 12 October 2012

  2. ME4/2 Chambers • Chamber factory is operating reliably • Chamber production rate ~1/week • Completed 19 chambers (out of 67 needed) • Chambers 211 – 218 in 2 month HV test • Chambers 219 and 220 in assembly area 211 212 218 213 214 215 216 217 219 220

  3. Final Assembly & Testing • Final Assembly • Add on-chamber electronics and cables • Assembly going well - ~1-2 days per chamber • Testing • All CSCs go through a 2-month HV test (up to 4KV – nominal HV is 3.6 KV) • On-chamber electronics tested -- 14 different tests including trigger, gas gain, cosmic ray data • Completed 10 chambers – rate limitation is production, not testing

  4. Chamber production chart Showing production rates for the 1stendcap (31 CSCs)

  5. ME1/1 Electronics I • ME1/1 Test Stand in B904 • 7 prototype DCFEBs have been installed & powered • Prototype LVDB board working fine • Cooling operational • Currents high - - roughly 50 amps per CSC • On-board temperatures ~30 C (reasonable) • Currently reading DCFEBs using copper skewclear cables and old DMB (can only read 5 boards) • Reading new TMB boards using optical fibers

  6. ME1/1 Electronics II • DCFEB boards • Most firmware operational - - currently working on the firmware for ODMB to enable data transfer to ODMB • FF_EMU ASIC • Currently does not work • Decision to focus effort on backup solution via Cu • ODMB • Prototype board exists at CERN, needs firmware • TMB • Received new firmware enabling full functionality

  7. ME1/1 Low Voltage • Design of LV system finalized • ME1/1 prototype test working well • Layout of cables & power supplies • Junction box prototype under construction • 8 Maraton power supplies ordered

More Related